利用研究级标签训练的深度学习模型对头部 CT 扫描颅内出血进行图像级精确定位。

IF 8.1 Q1 COMPUTER SCIENCE, ARTIFICIAL INTELLIGENCE
Yunan Wu, Michael Iorga, Suvarna Badhe, James Zhang, Donald R Cantrell, Elaine J Tanhehco, Nicholas Szrama, Andrew M Naidech, Michael Drakopoulos, Shamis T Hasan, Kunal M Patel, Tarek A Hijaz, Eric J Russell, Shamal Lalvani, Amit Adate, Todd B Parrish, Aggelos K Katsaggelos, Virginia B Hill
{"title":"利用研究级标签训练的深度学习模型对头部 CT 扫描颅内出血进行图像级精确定位。","authors":"Yunan Wu, Michael Iorga, Suvarna Badhe, James Zhang, Donald R Cantrell, Elaine J Tanhehco, Nicholas Szrama, Andrew M Naidech, Michael Drakopoulos, Shamis T Hasan, Kunal M Patel, Tarek A Hijaz, Eric J Russell, Shamal Lalvani, Amit Adate, Todd B Parrish, Aggelos K Katsaggelos, Virginia B Hill","doi":"10.1148/ryai.230296","DOIUrl":null,"url":null,"abstract":"<p><p><i>\"Just Accepted\" papers have undergone full peer review and have been accepted for publication in <i>Radiology: Artificial Intelligence</i>. This article will undergo copyediting, layout, and proof review before it is published in its final version. Please note that during production of the final copyedited article, errors may be discovered which could affect the content.</i> Purpose To develop a highly generalizable weakly supervised model to automatically detect and localize image- level intracranial hemorrhage (ICH) using study-level labels. Materials and Methods In this retrospective study, the proposed model was pretrained on the image-level RSNA dataset and fine-tuned on a local dataset using attention-based bidirectional long-short-term memory networks. This local training dataset included 10,699 noncontrast head CT scans from 7469 patients with ICH study-level labels extracted from radiology reports. Model performance was compared with that of two senior neuroradiologists on 100 random test scans using the McNemar test, and its generalizability was evaluated on an external independent dataset. Results The model achieved a positive predictive value (PPV) of 85.7% (95% CI: [84.0%, 87.4%]) and an AUC of 0.96 (95% CI: [0.96, 0.97]) on the held-out local test set (<i>n</i> = 7243, 3721 female) and 89.3% (95% CI: [87.8%, 90.7%]) and 0.96 (95% CI: [0.96, 0.97]), respectively, on the external test set (<i>n</i> = 491, 178 female). For 100 randomly selected samples, the model achieved performance on par with two neuroradiologists, but with a significantly faster (<i>P</i> < .05) diagnostic time of 5.04 seconds per scan (versus 86 seconds and 22.2 seconds for the two neuroradiologists, respectively). The model's attention weights and heatmaps visually aligned with neuroradiologists' interpretations. Conclusion The proposed model demonstrated high generalizability and high PPVs, offering a valuable tool for expedited ICH detection and prioritization while reducing false-positive interruptions in radiologists' workflows. ©RSNA, 2024.</p>","PeriodicalId":29787,"journal":{"name":"Radiology-Artificial Intelligence","volume":null,"pages":null},"PeriodicalIF":8.1000,"publicationDate":"2024-08-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Precise Image-level Localization of Intracranial Hemorrhage on Head CT Scans with Deep Learning Models Trained on Study-level Labels.\",\"authors\":\"Yunan Wu, Michael Iorga, Suvarna Badhe, James Zhang, Donald R Cantrell, Elaine J Tanhehco, Nicholas Szrama, Andrew M Naidech, Michael Drakopoulos, Shamis T Hasan, Kunal M Patel, Tarek A Hijaz, Eric J Russell, Shamal Lalvani, Amit Adate, Todd B Parrish, Aggelos K Katsaggelos, Virginia B Hill\",\"doi\":\"10.1148/ryai.230296\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p><i>\\\"Just Accepted\\\" papers have undergone full peer review and have been accepted for publication in <i>Radiology: Artificial Intelligence</i>. This article will undergo copyediting, layout, and proof review before it is published in its final version. Please note that during production of the final copyedited article, errors may be discovered which could affect the content.</i> Purpose To develop a highly generalizable weakly supervised model to automatically detect and localize image- level intracranial hemorrhage (ICH) using study-level labels. Materials and Methods In this retrospective study, the proposed model was pretrained on the image-level RSNA dataset and fine-tuned on a local dataset using attention-based bidirectional long-short-term memory networks. This local training dataset included 10,699 noncontrast head CT scans from 7469 patients with ICH study-level labels extracted from radiology reports. Model performance was compared with that of two senior neuroradiologists on 100 random test scans using the McNemar test, and its generalizability was evaluated on an external independent dataset. Results The model achieved a positive predictive value (PPV) of 85.7% (95% CI: [84.0%, 87.4%]) and an AUC of 0.96 (95% CI: [0.96, 0.97]) on the held-out local test set (<i>n</i> = 7243, 3721 female) and 89.3% (95% CI: [87.8%, 90.7%]) and 0.96 (95% CI: [0.96, 0.97]), respectively, on the external test set (<i>n</i> = 491, 178 female). For 100 randomly selected samples, the model achieved performance on par with two neuroradiologists, but with a significantly faster (<i>P</i> < .05) diagnostic time of 5.04 seconds per scan (versus 86 seconds and 22.2 seconds for the two neuroradiologists, respectively). The model's attention weights and heatmaps visually aligned with neuroradiologists' interpretations. Conclusion The proposed model demonstrated high generalizability and high PPVs, offering a valuable tool for expedited ICH detection and prioritization while reducing false-positive interruptions in radiologists' workflows. ©RSNA, 2024.</p>\",\"PeriodicalId\":29787,\"journal\":{\"name\":\"Radiology-Artificial Intelligence\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":8.1000,\"publicationDate\":\"2024-08-28\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Radiology-Artificial Intelligence\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1148/ryai.230296\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"COMPUTER SCIENCE, ARTIFICIAL INTELLIGENCE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Radiology-Artificial Intelligence","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1148/ryai.230296","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"COMPUTER SCIENCE, ARTIFICIAL INTELLIGENCE","Score":null,"Total":0}
引用次数: 0

摘要

"刚刚接受 "的论文经过同行评审,已被接受在《放射学》上发表:人工智能》上发表。这篇文章在以最终版本发表之前,还将经过校对、排版和校对审核。请注意,在制作最终校对稿的过程中,可能会发现影响文章内容的错误。目的 建立一个高度通用的弱监督模型,利用研究级标签自动检测和定位图像级颅内出血(ICH)。材料与方法 在这项回顾性研究中,利用基于注意力的双向长短期记忆网络,在图像级 RSNA 数据集上对所提出的模型进行了预训练,并在本地数据集上对其进行了微调。该本地训练数据集包括来自 7469 名患者的 10,699 张非对比头部 CT 扫描图像,这些图像带有从放射学报告中提取的 ICH 研究级标签。使用 McNemar 检验将模型的性能与两位资深神经放射学专家在 100 个随机测试扫描中的性能进行了比较,并在外部独立数据集上评估了模型的普适性。结果 在本地测试集(n = 7243,3721 名女性)上,该模型的阳性预测值(PPV)为 85.7%(95% CI:[84.0%, 87.4%]),AUC 为 0.96(95% CI:[0.96, 0.97]);在外部测试集(n = 491,178 名女性)上,该模型的阳性预测值(PPV)为 89.3%(95% CI:[87.8%, 90.7%]),AUC 为 0.96(95% CI:[0.96, 0.97])。在随机抽取的 100 个样本中,该模型的表现与两名神经放射科医生相当,但诊断时间明显更快(P < .05),每次扫描仅需 5.04 秒(而两名神经放射科医生的诊断时间分别为 86 秒和 22.2 秒)。该模型的注意力权重和热图与神经放射科医生的解释一致。结论 所提出的模型具有很高的普适性和 PPV 值,为加快 ICH 检测和优先排序提供了有价值的工具,同时减少了放射医师工作流程中假阳性的中断。©RSNA,2024。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Precise Image-level Localization of Intracranial Hemorrhage on Head CT Scans with Deep Learning Models Trained on Study-level Labels.

"Just Accepted" papers have undergone full peer review and have been accepted for publication in Radiology: Artificial Intelligence. This article will undergo copyediting, layout, and proof review before it is published in its final version. Please note that during production of the final copyedited article, errors may be discovered which could affect the content. Purpose To develop a highly generalizable weakly supervised model to automatically detect and localize image- level intracranial hemorrhage (ICH) using study-level labels. Materials and Methods In this retrospective study, the proposed model was pretrained on the image-level RSNA dataset and fine-tuned on a local dataset using attention-based bidirectional long-short-term memory networks. This local training dataset included 10,699 noncontrast head CT scans from 7469 patients with ICH study-level labels extracted from radiology reports. Model performance was compared with that of two senior neuroradiologists on 100 random test scans using the McNemar test, and its generalizability was evaluated on an external independent dataset. Results The model achieved a positive predictive value (PPV) of 85.7% (95% CI: [84.0%, 87.4%]) and an AUC of 0.96 (95% CI: [0.96, 0.97]) on the held-out local test set (n = 7243, 3721 female) and 89.3% (95% CI: [87.8%, 90.7%]) and 0.96 (95% CI: [0.96, 0.97]), respectively, on the external test set (n = 491, 178 female). For 100 randomly selected samples, the model achieved performance on par with two neuroradiologists, but with a significantly faster (P < .05) diagnostic time of 5.04 seconds per scan (versus 86 seconds and 22.2 seconds for the two neuroradiologists, respectively). The model's attention weights and heatmaps visually aligned with neuroradiologists' interpretations. Conclusion The proposed model demonstrated high generalizability and high PPVs, offering a valuable tool for expedited ICH detection and prioritization while reducing false-positive interruptions in radiologists' workflows. ©RSNA, 2024.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
16.20
自引率
1.00%
发文量
0
期刊介绍: Radiology: Artificial Intelligence is a bi-monthly publication that focuses on the emerging applications of machine learning and artificial intelligence in the field of imaging across various disciplines. This journal is available online and accepts multiple manuscript types, including Original Research, Technical Developments, Data Resources, Review articles, Editorials, Letters to the Editor and Replies, Special Reports, and AI in Brief.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信