研究脉冲场消融参数与消融结果之间的关系。

IF 2.1 4区 医学 Q3 CARDIAC & CARDIOVASCULAR SYSTEMS
Lianru Zang, Kaihao Gu, Tuo Zhou, Peng Si, Xingkai Ji, Hao Zhang, Shengjie Yan, Xiaomei Wu
{"title":"研究脉冲场消融参数与消融结果之间的关系。","authors":"Lianru Zang, Kaihao Gu, Tuo Zhou, Peng Si, Xingkai Ji, Hao Zhang, Shengjie Yan, Xiaomei Wu","doi":"10.1007/s10840-024-01872-1","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Pulsed field ablation (PFA) is an emerging non-thermal ablation method. The primary challenge is the control of multiple parameters in PFA, as the interplay of these parameters remains unclear in terms of ensuring effective and safe tissue ablation.</p><p><strong>Purpose: </strong>This study employs the response surface method (RSM) to explore the interactions between various PFA parameters and ablation outcomes, and seeks to enhance the efficacy and safety of PFA.</p><p><strong>Methods: </strong>In vivo experiments were conducted using rabbit liver for varying PFA parameters: pulse amplitude (PA), pulse interval (PI), number of pulse trains (NT), and number of pulses in a pulse train (NP). Ablation outcomes assessed included three ablation sizes, surface temperature, and muscle contraction strength. Additionally, histological analysis was performed on the ablated tissue. We analyzed the relationship between PFA parameters and ablation outcomes, and results were then compared with those from a simulation using an electric-thermal coupling PFA finite element model.</p><p><strong>Results: </strong>A linear relationship between ablation outcomes and PFA parameters was established. PA and NT exhibited extremely significant (P < 0.0001) and significant effects (P < 0.05) on all ablation outcomes, respectively. NP showed an extremely significant impact (P < 0.0001) on surface temperature and muscle contraction strength, while PI significantly influenced (P < 0.05) muscle contraction strength alone. Histological analysis revealed that PFA produces controlled, well-defined areas of liver tissue necrosis. Surface temperature results from simulations and experiments were highly consistent (R<sup>2</sup> > 0.97).</p><p><strong>Conclusions: </strong>This study clarifies the relationship between various PFA parameters and ablation outcomes, and aims to improve the efficacy and safety of PFA.</p>","PeriodicalId":16202,"journal":{"name":"Journal of Interventional Cardiac Electrophysiology","volume":null,"pages":null},"PeriodicalIF":2.1000,"publicationDate":"2024-08-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Investigate the relationship between pulsed field ablation parameters and ablation outcomes.\",\"authors\":\"Lianru Zang, Kaihao Gu, Tuo Zhou, Peng Si, Xingkai Ji, Hao Zhang, Shengjie Yan, Xiaomei Wu\",\"doi\":\"10.1007/s10840-024-01872-1\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>Pulsed field ablation (PFA) is an emerging non-thermal ablation method. The primary challenge is the control of multiple parameters in PFA, as the interplay of these parameters remains unclear in terms of ensuring effective and safe tissue ablation.</p><p><strong>Purpose: </strong>This study employs the response surface method (RSM) to explore the interactions between various PFA parameters and ablation outcomes, and seeks to enhance the efficacy and safety of PFA.</p><p><strong>Methods: </strong>In vivo experiments were conducted using rabbit liver for varying PFA parameters: pulse amplitude (PA), pulse interval (PI), number of pulse trains (NT), and number of pulses in a pulse train (NP). Ablation outcomes assessed included three ablation sizes, surface temperature, and muscle contraction strength. Additionally, histological analysis was performed on the ablated tissue. We analyzed the relationship between PFA parameters and ablation outcomes, and results were then compared with those from a simulation using an electric-thermal coupling PFA finite element model.</p><p><strong>Results: </strong>A linear relationship between ablation outcomes and PFA parameters was established. PA and NT exhibited extremely significant (P < 0.0001) and significant effects (P < 0.05) on all ablation outcomes, respectively. NP showed an extremely significant impact (P < 0.0001) on surface temperature and muscle contraction strength, while PI significantly influenced (P < 0.05) muscle contraction strength alone. Histological analysis revealed that PFA produces controlled, well-defined areas of liver tissue necrosis. Surface temperature results from simulations and experiments were highly consistent (R<sup>2</sup> > 0.97).</p><p><strong>Conclusions: </strong>This study clarifies the relationship between various PFA parameters and ablation outcomes, and aims to improve the efficacy and safety of PFA.</p>\",\"PeriodicalId\":16202,\"journal\":{\"name\":\"Journal of Interventional Cardiac Electrophysiology\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":2.1000,\"publicationDate\":\"2024-08-26\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Interventional Cardiac Electrophysiology\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1007/s10840-024-01872-1\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"CARDIAC & CARDIOVASCULAR SYSTEMS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Interventional Cardiac Electrophysiology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s10840-024-01872-1","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0

摘要

背景:脉冲场消融(PFA)是一种新兴的非热消融方法。目的:本研究采用响应面法(RSM)来探索 PFA 各参数与消融结果之间的相互作用,力求提高 PFA 的有效性和安全性:使用兔肝脏进行体内实验,改变 PFA 参数:脉冲幅度 (PA)、脉冲间隔 (PI)、脉冲序列数 (NT) 和脉冲序列中的脉冲数 (NP)。消融结果评估包括三种消融大小、表面温度和肌肉收缩强度。此外,还对消融组织进行了组织学分析。我们分析了 PFA 参数与消融结果之间的关系,然后将结果与使用电热耦合 PFA 有限元模型进行的模拟结果进行了比较:结果:消融结果与 PFA 参数之间存在线性关系。结果:消融结果与 PFA 参数之间存在线性关系,PA 和 NT 具有极其显著的相关性(P 2 > 0.97):本研究阐明了各种 PFA 参数与消融结果之间的关系,旨在提高 PFA 的有效性和安全性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

Investigate the relationship between pulsed field ablation parameters and ablation outcomes.

Investigate the relationship between pulsed field ablation parameters and ablation outcomes.

Background: Pulsed field ablation (PFA) is an emerging non-thermal ablation method. The primary challenge is the control of multiple parameters in PFA, as the interplay of these parameters remains unclear in terms of ensuring effective and safe tissue ablation.

Purpose: This study employs the response surface method (RSM) to explore the interactions between various PFA parameters and ablation outcomes, and seeks to enhance the efficacy and safety of PFA.

Methods: In vivo experiments were conducted using rabbit liver for varying PFA parameters: pulse amplitude (PA), pulse interval (PI), number of pulse trains (NT), and number of pulses in a pulse train (NP). Ablation outcomes assessed included three ablation sizes, surface temperature, and muscle contraction strength. Additionally, histological analysis was performed on the ablated tissue. We analyzed the relationship between PFA parameters and ablation outcomes, and results were then compared with those from a simulation using an electric-thermal coupling PFA finite element model.

Results: A linear relationship between ablation outcomes and PFA parameters was established. PA and NT exhibited extremely significant (P < 0.0001) and significant effects (P < 0.05) on all ablation outcomes, respectively. NP showed an extremely significant impact (P < 0.0001) on surface temperature and muscle contraction strength, while PI significantly influenced (P < 0.05) muscle contraction strength alone. Histological analysis revealed that PFA produces controlled, well-defined areas of liver tissue necrosis. Surface temperature results from simulations and experiments were highly consistent (R2 > 0.97).

Conclusions: This study clarifies the relationship between various PFA parameters and ablation outcomes, and aims to improve the efficacy and safety of PFA.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
4.30
自引率
11.10%
发文量
320
审稿时长
4-8 weeks
期刊介绍: The Journal of Interventional Cardiac Electrophysiology is an international publication devoted to fostering research in and development of interventional techniques and therapies for the management of cardiac arrhythmias. It is designed primarily to present original research studies and scholarly scientific reviews of basic and applied science and clinical research in this field. The Journal will adopt a multidisciplinary approach to link physical, experimental, and clinical sciences as applied to the development of and practice in interventional electrophysiology. The Journal will examine techniques ranging from molecular, chemical and pharmacologic therapies to device and ablation technology. Accordingly, original research in clinical, epidemiologic and basic science arenas will be considered for publication. Applied engineering or physical science studies pertaining to interventional electrophysiology will be encouraged. The Journal is committed to providing comprehensive and detailed treatment of major interventional therapies and innovative techniques in a structured and clinically relevant manner. It is directed at clinical practitioners and investigators in the rapidly growing field of interventional electrophysiology. The editorial staff and board reflect this bias and include noted international experts in this area with a wealth of expertise in basic and clinical investigation. Peer review of all submissions, conflict of interest guidelines and periodic editorial board review of all Journal policies have been established.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信