胫骨外侧平台骨折内固定的生物力学稳定性计算分析:机械稳定性研究。

IF 1.7 4区 医学 Q3 ENGINEERING, BIOMEDICAL
Yafeng Li, Fengyuan Lu, Peng Yi, Zichun Zou, Xi Zhang, Jing Zhang
{"title":"胫骨外侧平台骨折内固定的生物力学稳定性计算分析:机械稳定性研究。","authors":"Yafeng Li, Fengyuan Lu, Peng Yi, Zichun Zou, Xi Zhang, Jing Zhang","doi":"10.1177/09544119241272782","DOIUrl":null,"url":null,"abstract":"<p><p>The selection of internal fixation as the primary fixation modality for the patient is one of the challenges for the surgeon treating the patient in question. A model of the lateral tibial plateau fracture was established. Three different configurations of internal fixators namely L bone plate, T bone plate, and screw-washer were analyzed. Three stages after surgery were simulated to assess the displacement of bone plates, screws, washers, and the stress shielding ratio in the fracture area.At three stages after surgery, the T bone plate showed better stability for patients during rehabilitation compared with the remaining two schemes, and the screw-washer scheme was the least stable due to the larger internal fixation displacement and stress shielding ratio in the fracture area. In contrast, the L bone plate scheme showed better stability in the early stages after surgery but was second only to the screw-washer scheme in the middle and late stages after surgery. The T bone plate showed better stability and became a new selection for surgeons to treat related patients. At three stages after surgery, the T bone plate has better biomechanical stability compared to the L bone plate and screw-washer schemes.</p>","PeriodicalId":20666,"journal":{"name":"Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine","volume":null,"pages":null},"PeriodicalIF":1.7000,"publicationDate":"2024-08-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Computational analysis of the biomechanical stability of internal fixation of the lateral tibial plateau fracture: A mechanical stability study.\",\"authors\":\"Yafeng Li, Fengyuan Lu, Peng Yi, Zichun Zou, Xi Zhang, Jing Zhang\",\"doi\":\"10.1177/09544119241272782\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The selection of internal fixation as the primary fixation modality for the patient is one of the challenges for the surgeon treating the patient in question. A model of the lateral tibial plateau fracture was established. Three different configurations of internal fixators namely L bone plate, T bone plate, and screw-washer were analyzed. Three stages after surgery were simulated to assess the displacement of bone plates, screws, washers, and the stress shielding ratio in the fracture area.At three stages after surgery, the T bone plate showed better stability for patients during rehabilitation compared with the remaining two schemes, and the screw-washer scheme was the least stable due to the larger internal fixation displacement and stress shielding ratio in the fracture area. In contrast, the L bone plate scheme showed better stability in the early stages after surgery but was second only to the screw-washer scheme in the middle and late stages after surgery. The T bone plate showed better stability and became a new selection for surgeons to treat related patients. At three stages after surgery, the T bone plate has better biomechanical stability compared to the L bone plate and screw-washer schemes.</p>\",\"PeriodicalId\":20666,\"journal\":{\"name\":\"Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.7000,\"publicationDate\":\"2024-08-24\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.1177/09544119241272782\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"ENGINEERING, BIOMEDICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1177/09544119241272782","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0

摘要

选择内固定作为患者的主要固定方式,是外科医生在治疗患者时面临的挑战之一。我们建立了一个胫骨外侧平台骨折模型。分析了三种不同配置的内固定器,即 L 型骨板、T 型骨板和螺钉垫圈。模拟术后三个阶段,评估骨板、螺钉、垫圈的位移以及骨折区域的应力屏蔽比。术后三个阶段,T 型骨板与其余两种方案相比,在患者康复期间表现出更好的稳定性,而螺钉垫圈方案由于骨折区域的内固定位移和应力屏蔽比较大,稳定性最差。相比之下,L 型骨板方案在术后早期的稳定性较好,但在术后中后期的稳定性仅次于螺钉垫圈方案。T 型骨板显示出更好的稳定性,成为外科医生治疗相关患者的新选择。在术后三个阶段,与 L 型骨板和螺钉垫圈方案相比,T 型骨板具有更好的生物力学稳定性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Computational analysis of the biomechanical stability of internal fixation of the lateral tibial plateau fracture: A mechanical stability study.

The selection of internal fixation as the primary fixation modality for the patient is one of the challenges for the surgeon treating the patient in question. A model of the lateral tibial plateau fracture was established. Three different configurations of internal fixators namely L bone plate, T bone plate, and screw-washer were analyzed. Three stages after surgery were simulated to assess the displacement of bone plates, screws, washers, and the stress shielding ratio in the fracture area.At three stages after surgery, the T bone plate showed better stability for patients during rehabilitation compared with the remaining two schemes, and the screw-washer scheme was the least stable due to the larger internal fixation displacement and stress shielding ratio in the fracture area. In contrast, the L bone plate scheme showed better stability in the early stages after surgery but was second only to the screw-washer scheme in the middle and late stages after surgery. The T bone plate showed better stability and became a new selection for surgeons to treat related patients. At three stages after surgery, the T bone plate has better biomechanical stability compared to the L bone plate and screw-washer schemes.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
3.60
自引率
5.60%
发文量
122
审稿时长
6 months
期刊介绍: The Journal of Engineering in Medicine is an interdisciplinary journal encompassing all aspects of engineering in medicine. The Journal is a vital tool for maintaining an understanding of the newest techniques and research in medical engineering.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信