{"title":"弗莱克维赫奶牛因笼子磁铁引起的十二指肠回流。","authors":"Lisa Huber, Melanie Feist, Gabriela Knubben-Schweizer, Florian M Trefz","doi":"10.1055/a-2365-5457","DOIUrl":null,"url":null,"abstract":"<p><p>The present report aims to describe the case of a duodenal obstruction ileus in a dairy cow that was caused by a cage magnet. The 4.7-year-old German Fleckvieh cow was hospitalized because of symptoms of intestinal obstruction such as anorexia, noticeable drop in milk yield, reduced defecation, dehydration and positive percussion and swinging auscultation in a circumscribed area cranial of the right flank over the last 2 ribs. Six months as well as 3 days prior to hospitalization the cow had already been treated for signs of hardware disease, which included administration of a cage magnet.After the initial clinical diagnostic procedure on hospital admission, a diagnostic laparotomy in the right paralumbar fossa was performed to identify the cause of the ileus. The cranial part of the duodenum was markedly dilated, and a solid foreign body was found obstructing the intestine immediately aboral to the duodenal sigmoid flexure. This was identified as a cage magnet, which was massaged in retrograde direction into the pyloric antrum and removed via abomasotomy. The cow recovered from surgical intervention and was discharged from the hospital 6 days later.The present report describes an unusual complication of cage magnet administration, which is a standard veterinary procedure and generally considered a safe treatment option in cows with clinical signs of acute traumatic reticuloperitonitis.</p>","PeriodicalId":23115,"journal":{"name":"Tieraerztliche Praxis Ausgabe Grosstiere Nutztiere","volume":null,"pages":null},"PeriodicalIF":0.4000,"publicationDate":"2024-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Duodenal ileus caused by a cage magnet in a Fleckvieh cow.\",\"authors\":\"Lisa Huber, Melanie Feist, Gabriela Knubben-Schweizer, Florian M Trefz\",\"doi\":\"10.1055/a-2365-5457\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The present report aims to describe the case of a duodenal obstruction ileus in a dairy cow that was caused by a cage magnet. The 4.7-year-old German Fleckvieh cow was hospitalized because of symptoms of intestinal obstruction such as anorexia, noticeable drop in milk yield, reduced defecation, dehydration and positive percussion and swinging auscultation in a circumscribed area cranial of the right flank over the last 2 ribs. Six months as well as 3 days prior to hospitalization the cow had already been treated for signs of hardware disease, which included administration of a cage magnet.After the initial clinical diagnostic procedure on hospital admission, a diagnostic laparotomy in the right paralumbar fossa was performed to identify the cause of the ileus. The cranial part of the duodenum was markedly dilated, and a solid foreign body was found obstructing the intestine immediately aboral to the duodenal sigmoid flexure. This was identified as a cage magnet, which was massaged in retrograde direction into the pyloric antrum and removed via abomasotomy. The cow recovered from surgical intervention and was discharged from the hospital 6 days later.The present report describes an unusual complication of cage magnet administration, which is a standard veterinary procedure and generally considered a safe treatment option in cows with clinical signs of acute traumatic reticuloperitonitis.</p>\",\"PeriodicalId\":23115,\"journal\":{\"name\":\"Tieraerztliche Praxis Ausgabe Grosstiere Nutztiere\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.4000,\"publicationDate\":\"2024-08-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Tieraerztliche Praxis Ausgabe Grosstiere Nutztiere\",\"FirstCategoryId\":\"97\",\"ListUrlMain\":\"https://doi.org/10.1055/a-2365-5457\",\"RegionNum\":4,\"RegionCategory\":\"农林科学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/8/22 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q4\",\"JCRName\":\"VETERINARY SCIENCES\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Tieraerztliche Praxis Ausgabe Grosstiere Nutztiere","FirstCategoryId":"97","ListUrlMain":"https://doi.org/10.1055/a-2365-5457","RegionNum":4,"RegionCategory":"农林科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/8/22 0:00:00","PubModel":"Epub","JCR":"Q4","JCRName":"VETERINARY SCIENCES","Score":null,"Total":0}
Duodenal ileus caused by a cage magnet in a Fleckvieh cow.
The present report aims to describe the case of a duodenal obstruction ileus in a dairy cow that was caused by a cage magnet. The 4.7-year-old German Fleckvieh cow was hospitalized because of symptoms of intestinal obstruction such as anorexia, noticeable drop in milk yield, reduced defecation, dehydration and positive percussion and swinging auscultation in a circumscribed area cranial of the right flank over the last 2 ribs. Six months as well as 3 days prior to hospitalization the cow had already been treated for signs of hardware disease, which included administration of a cage magnet.After the initial clinical diagnostic procedure on hospital admission, a diagnostic laparotomy in the right paralumbar fossa was performed to identify the cause of the ileus. The cranial part of the duodenum was markedly dilated, and a solid foreign body was found obstructing the intestine immediately aboral to the duodenal sigmoid flexure. This was identified as a cage magnet, which was massaged in retrograde direction into the pyloric antrum and removed via abomasotomy. The cow recovered from surgical intervention and was discharged from the hospital 6 days later.The present report describes an unusual complication of cage magnet administration, which is a standard veterinary procedure and generally considered a safe treatment option in cows with clinical signs of acute traumatic reticuloperitonitis.
期刊介绍:
Die Tierärztliche Praxis wendet sich mit ihren beiden Reihen als einzige veterinärmedizinische Fachzeitschrift explizit an den Großtier- bzw. Kleintierpraktiker und garantiert damit eine zielgruppengenaue Ansprache. Für den Spezialisten bietet sie Original- oder Übersichtsartikel zu neuen Therapie- und Operationsverfahren oder den Einsatz moderner bildgebender Verfahren. Der weniger spezialisierte Tierarzt oder Berufseinsteiger findet auf seinen Berufsalltag zugeschnittene praxisbezogene Beiträge in der Fortbildungsrubrik „Aus Studium und Praxis“. Mit dem hervorgehobenen „Fazit für die Praxis“ am Ende jedes Artikels verschafft sich auch der eilige Leser einen raschen Überblick über die wichtigsten Inhalte dieser modern konzipierten Fachzeitschrift mit den vielen hochwertigen, überwiegend farbigen Abbildungen. In jedem Heft ermöglicht ein ATF-anerkannter Fortbildungsartikel den Erwerb einer ATF-Stunde (Akademie für tierärztliche Fortbildung).