{"title":"利用幂律溶血模型中使用的不同系数集和标度剪切应力模型,对 FDA 基准血泵进行计算流体动力学模拟。","authors":"Ahmet Onder, Omer Incebay, Rafet Yapici","doi":"10.1007/s10047-024-01468-6","DOIUrl":null,"url":null,"abstract":"<p><p>Hemolysis is the most important issue to consider in the design and optimization of blood-contacting devices. Although the use of Computational Fluid Dynamics (CFD) in hemolysis prediction studies provides convenience and has promising potential, it is an extremely challenging process. Hemolysis predictions with CFD depend on the mesh, implementation method, coefficient set, and scalar-shear-stress model. To this end, an attempt was made to find the combination that would provide the most accurate result in hemolysis prediction with the commonly cited power-law based hemolysis model. In the hemolysis predictions conducted using CFD on the Food and Drug Administration (FDA) benchmark blood pump, 3 different scalar-shear-stress models, and 5 different coefficient sets with the power-law based hemolysis model were used. Also, a mesh independence test based on hemolysis and pressure head was performed. The pressure head results of CFD simulations were compared with published pressure head of the FDA benchmark blood pump and a good agreement was observed. In addition, results of CFD-hemolysis predictions which are conducted with scalar-shear-stress model and coefficient set combinations were compared with experimental hemolysis data at three operating conditions such as 6-7 L/min flow rates at 3500 rpm rotational speeds and 6 L/min at 2500 rpm. One of the combinations of the scalar-shear-stress model and the coefficient set was found to be within the error limits of the experimental measurements, while all other combinations overestimated hemolysis.</p>","PeriodicalId":15177,"journal":{"name":"Journal of Artificial Organs","volume":" ","pages":""},"PeriodicalIF":1.1000,"publicationDate":"2024-08-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Computational fluid dynamics simulating of the FDA benchmark blood pump with different coefficient sets and scaler shear stress models used in the power-law hemolysis model.\",\"authors\":\"Ahmet Onder, Omer Incebay, Rafet Yapici\",\"doi\":\"10.1007/s10047-024-01468-6\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Hemolysis is the most important issue to consider in the design and optimization of blood-contacting devices. Although the use of Computational Fluid Dynamics (CFD) in hemolysis prediction studies provides convenience and has promising potential, it is an extremely challenging process. Hemolysis predictions with CFD depend on the mesh, implementation method, coefficient set, and scalar-shear-stress model. To this end, an attempt was made to find the combination that would provide the most accurate result in hemolysis prediction with the commonly cited power-law based hemolysis model. In the hemolysis predictions conducted using CFD on the Food and Drug Administration (FDA) benchmark blood pump, 3 different scalar-shear-stress models, and 5 different coefficient sets with the power-law based hemolysis model were used. Also, a mesh independence test based on hemolysis and pressure head was performed. The pressure head results of CFD simulations were compared with published pressure head of the FDA benchmark blood pump and a good agreement was observed. In addition, results of CFD-hemolysis predictions which are conducted with scalar-shear-stress model and coefficient set combinations were compared with experimental hemolysis data at three operating conditions such as 6-7 L/min flow rates at 3500 rpm rotational speeds and 6 L/min at 2500 rpm. One of the combinations of the scalar-shear-stress model and the coefficient set was found to be within the error limits of the experimental measurements, while all other combinations overestimated hemolysis.</p>\",\"PeriodicalId\":15177,\"journal\":{\"name\":\"Journal of Artificial Organs\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":1.1000,\"publicationDate\":\"2024-08-23\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Artificial Organs\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.1007/s10047-024-01468-6\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"ENGINEERING, BIOMEDICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Artificial Organs","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1007/s10047-024-01468-6","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
Computational fluid dynamics simulating of the FDA benchmark blood pump with different coefficient sets and scaler shear stress models used in the power-law hemolysis model.
Hemolysis is the most important issue to consider in the design and optimization of blood-contacting devices. Although the use of Computational Fluid Dynamics (CFD) in hemolysis prediction studies provides convenience and has promising potential, it is an extremely challenging process. Hemolysis predictions with CFD depend on the mesh, implementation method, coefficient set, and scalar-shear-stress model. To this end, an attempt was made to find the combination that would provide the most accurate result in hemolysis prediction with the commonly cited power-law based hemolysis model. In the hemolysis predictions conducted using CFD on the Food and Drug Administration (FDA) benchmark blood pump, 3 different scalar-shear-stress models, and 5 different coefficient sets with the power-law based hemolysis model were used. Also, a mesh independence test based on hemolysis and pressure head was performed. The pressure head results of CFD simulations were compared with published pressure head of the FDA benchmark blood pump and a good agreement was observed. In addition, results of CFD-hemolysis predictions which are conducted with scalar-shear-stress model and coefficient set combinations were compared with experimental hemolysis data at three operating conditions such as 6-7 L/min flow rates at 3500 rpm rotational speeds and 6 L/min at 2500 rpm. One of the combinations of the scalar-shear-stress model and the coefficient set was found to be within the error limits of the experimental measurements, while all other combinations overestimated hemolysis.
期刊介绍:
The aim of the Journal of Artificial Organs is to introduce to colleagues worldwide a broad spectrum of important new achievements in the field of artificial organs, ranging from fundamental research to clinical applications. The scope of the Journal of Artificial Organs encompasses but is not restricted to blood purification, cardiovascular intervention, biomaterials, and artificial metabolic organs. Additionally, the journal will cover technical and industrial innovations. Membership in the Japanese Society for Artificial Organs is not a prerequisite for submission.