{"title":"基于宽视场扫源 OCT 评估无眼疾患者的视网膜体积","authors":"Yoshiaki Chiku MD,&nbsp;Takao Hirano MD, PhD,&nbsp;Ken Hoshiyama MD,&nbsp;Yasuhiro Iesato MD, PhD,&nbsp;Toshinori Murata MD, PhD","doi":"10.1016/j.xops.2024.100569","DOIUrl":null,"url":null,"abstract":"<div><h3>Purpose</h3><p>To evaluate retinal volume (RV) in eyes without retinal disease using wide-field swept-source OCT (SS-OCT).</p></div><div><h3>Design</h3><p>Observational, cross-sectional design.</p></div><div><h3>Participants</h3><p>A total of 332 eyes of 166 healthy participants.</p></div><div><h3>Methods</h3><p>The eyes were imaged with OCT-S1 (Canon) using a protocol centered on the fovea cube scans (20 × 23 mm) of SS-OCT images. Retinal volume (6-mm circle, 6–20-mm ring) and various parameters were evaluated in a multivariate analysis using a generalized estimating equation model. Each quadrant of the macula except for the fovea (1–6 mm in diameter) and peripheral ring (6–20 mm in diameter) was also evaluated.</p></div><div><h3>Main Outcome Measures</h3><p>Retinal volume.</p></div><div><h3>Results</h3><p>In the multivariate analysis, older age and longer axial length were associated with smaller macular RV, whereas older age and left eye were associated with smaller peripheral RV. The temporal area was significantly smaller than all other areas in the macula (1–6 mm), whereas the inferior area was significantly smaller than all other areas in the peripheral retina (6–20 mm).</p></div><div><h3>Conclusions</h3><p>In wide-field SS-OCT images, age and left eye are negatively correlated with peripheral RV. The thinnest part of the retinal quadrant differs between the macular and peripheral retinas.</p></div><div><h3>Financial Disclosure(s)</h3><p>Proprietary or commercial disclosure may be found in the Footnotes and Disclosures at the end of this article.</p></div>","PeriodicalId":74363,"journal":{"name":"Ophthalmology science","volume":null,"pages":null},"PeriodicalIF":3.2000,"publicationDate":"2024-06-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.sciencedirect.com/science/article/pii/S2666914524001052/pdfft?md5=394b3468fb665e4d2094d378b0d55297&pid=1-s2.0-S2666914524001052-main.pdf","citationCount":"0","resultStr":"{\"title\":\"Assessment of Retinal Volume in Individuals Without Ocular Disorders Based on Wide-Field Swept-Source OCT\",\"authors\":\"Yoshiaki Chiku MD,&nbsp;Takao Hirano MD, PhD,&nbsp;Ken Hoshiyama MD,&nbsp;Yasuhiro Iesato MD, PhD,&nbsp;Toshinori Murata MD, PhD\",\"doi\":\"10.1016/j.xops.2024.100569\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><h3>Purpose</h3><p>To evaluate retinal volume (RV) in eyes without retinal disease using wide-field swept-source OCT (SS-OCT).</p></div><div><h3>Design</h3><p>Observational, cross-sectional design.</p></div><div><h3>Participants</h3><p>A total of 332 eyes of 166 healthy participants.</p></div><div><h3>Methods</h3><p>The eyes were imaged with OCT-S1 (Canon) using a protocol centered on the fovea cube scans (20 × 23 mm) of SS-OCT images. Retinal volume (6-mm circle, 6–20-mm ring) and various parameters were evaluated in a multivariate analysis using a generalized estimating equation model. Each quadrant of the macula except for the fovea (1–6 mm in diameter) and peripheral ring (6–20 mm in diameter) was also evaluated.</p></div><div><h3>Main Outcome Measures</h3><p>Retinal volume.</p></div><div><h3>Results</h3><p>In the multivariate analysis, older age and longer axial length were associated with smaller macular RV, whereas older age and left eye were associated with smaller peripheral RV. The temporal area was significantly smaller than all other areas in the macula (1–6 mm), whereas the inferior area was significantly smaller than all other areas in the peripheral retina (6–20 mm).</p></div><div><h3>Conclusions</h3><p>In wide-field SS-OCT images, age and left eye are negatively correlated with peripheral RV. The thinnest part of the retinal quadrant differs between the macular and peripheral retinas.</p></div><div><h3>Financial Disclosure(s)</h3><p>Proprietary or commercial disclosure may be found in the Footnotes and Disclosures at the end of this article.</p></div>\",\"PeriodicalId\":74363,\"journal\":{\"name\":\"Ophthalmology science\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":3.2000,\"publicationDate\":\"2024-06-21\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.sciencedirect.com/science/article/pii/S2666914524001052/pdfft?md5=394b3468fb665e4d2094d378b0d55297&pid=1-s2.0-S2666914524001052-main.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Ophthalmology science\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S2666914524001052\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"OPHTHALMOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Ophthalmology science","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2666914524001052","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

目的使用宽视场扫源 OCT(SS-OCT)评估无视网膜疾病眼的视网膜体积(RV)。方法使用 OCT-S1(佳能)对眼部进行成像,成像方案以 SS-OCT 图像的眼窝立方体扫描(20 × 23 毫米)为中心。使用广义估计方程模型对视网膜体积(6 毫米圆环、6-20 毫米环)和各种参数进行多变量分析评估。主要结果测量视网膜体积。结果在多变量分析中,年龄越大、轴向长度越长,黄斑视网膜体积越小;年龄越大、左眼视网膜体积越小。结论在宽视野 SS-OCT 图像中,年龄和左眼与周边 RV 呈负相关。视网膜象限最薄的部分在黄斑视网膜和周边视网膜之间存在差异。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Assessment of Retinal Volume in Individuals Without Ocular Disorders Based on Wide-Field Swept-Source OCT

Purpose

To evaluate retinal volume (RV) in eyes without retinal disease using wide-field swept-source OCT (SS-OCT).

Design

Observational, cross-sectional design.

Participants

A total of 332 eyes of 166 healthy participants.

Methods

The eyes were imaged with OCT-S1 (Canon) using a protocol centered on the fovea cube scans (20 × 23 mm) of SS-OCT images. Retinal volume (6-mm circle, 6–20-mm ring) and various parameters were evaluated in a multivariate analysis using a generalized estimating equation model. Each quadrant of the macula except for the fovea (1–6 mm in diameter) and peripheral ring (6–20 mm in diameter) was also evaluated.

Main Outcome Measures

Retinal volume.

Results

In the multivariate analysis, older age and longer axial length were associated with smaller macular RV, whereas older age and left eye were associated with smaller peripheral RV. The temporal area was significantly smaller than all other areas in the macula (1–6 mm), whereas the inferior area was significantly smaller than all other areas in the peripheral retina (6–20 mm).

Conclusions

In wide-field SS-OCT images, age and left eye are negatively correlated with peripheral RV. The thinnest part of the retinal quadrant differs between the macular and peripheral retinas.

Financial Disclosure(s)

Proprietary or commercial disclosure may be found in the Footnotes and Disclosures at the end of this article.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Ophthalmology science
Ophthalmology science Ophthalmology
CiteScore
3.40
自引率
0.00%
发文量
0
审稿时长
89 days
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信