人工智能辅助体积各向同性同步交错亮血和黑血检查脑转移瘤。

IF 4.6 Q2 MATERIALS SCIENCE, BIOMATERIALS
Kazufumi Kikuchi, Osamu Togao, Yoshitomo Kikuchi, Koji Yamashita, Daichi Momosaka, Kazunori Fukasawa, Shunsuke Nishimura, Hiroyuki Toyoda, Makoto Obara, Akio Hiwatashi, Kousei Ishigami
{"title":"人工智能辅助体积各向同性同步交错亮血和黑血检查脑转移瘤。","authors":"Kazufumi Kikuchi, Osamu Togao, Yoshitomo Kikuchi, Koji Yamashita, Daichi Momosaka, Kazunori Fukasawa, Shunsuke Nishimura, Hiroyuki Toyoda, Makoto Obara, Akio Hiwatashi, Kousei Ishigami","doi":"10.1007/s00234-024-03454-4","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To verify the effectiveness of artificial intelligence-assisted volume isotropic simultaneous interleaved bright-/black-blood examination (AI-VISIBLE) for detecting brain metastases.</p><p><strong>Methods: </strong>This retrospective study was approved by our institutional review board and the requirement for written informed consent was waived. Forty patients were included: 20 patients with and without brain metastases each. Seven independent observers (three radiology residents and four neuroradiologists) participated in two reading sessions: in the first, brain metastases were detected using VISIBLE only; in the second, the results of the first session were comprehensively evaluated by adding AI-VISIBLE information. Sensitivity, diagnostic performance, and false positives/case were evaluated. Diagnostic performance was assessed using a figure-of-merit (FOM). Sensitivity and false positives/case were evaluated using McNemar and paired t-tests, respectively.</p><p><strong>Results: </strong>The McNemar test revealed a significant difference between VISIBLE with/without AI information (P < 0.0001). Significantly higher sensitivity (94.9 ± 1.7% vs. 88.3 ± 5.1%, P = 0.0028) and FOM (0.983 ± 0.009 vs. 0.972 ± 0.013, P = 0.0063) were achieved using VISIBLE with AI information vs. without. No significant difference was observed in false positives/case with and without AI information (0.23 ± 0.19 vs. 0.18 ± 0.15, P = 0.250). AI-assisted results of radiology residents became comparable to results of neuroradiologists (sensitivity, FOM: 85.9 ± 3.4% vs. 90.0 ± 5.9%, 0.969 ± 0.016 vs. 0.974 ± 0.012 without AI information; 94.8 ± 1.3% vs. 95.0 ± 2.1%, 0.977 ± 0.010 vs. 0.988 ± 0.005 with AI information, respectively).</p><p><strong>Conclusion: </strong>AI-VISIBLE improved the sensitivity and performance for diagnosing brain metastases.</p>","PeriodicalId":2,"journal":{"name":"ACS Applied Bio Materials","volume":null,"pages":null},"PeriodicalIF":4.6000,"publicationDate":"2024-08-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Artificial intelligence-assisted volume isotropic simultaneous interleaved bright- and black-blood examination for brain metastases.\",\"authors\":\"Kazufumi Kikuchi, Osamu Togao, Yoshitomo Kikuchi, Koji Yamashita, Daichi Momosaka, Kazunori Fukasawa, Shunsuke Nishimura, Hiroyuki Toyoda, Makoto Obara, Akio Hiwatashi, Kousei Ishigami\",\"doi\":\"10.1007/s00234-024-03454-4\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>To verify the effectiveness of artificial intelligence-assisted volume isotropic simultaneous interleaved bright-/black-blood examination (AI-VISIBLE) for detecting brain metastases.</p><p><strong>Methods: </strong>This retrospective study was approved by our institutional review board and the requirement for written informed consent was waived. Forty patients were included: 20 patients with and without brain metastases each. Seven independent observers (three radiology residents and four neuroradiologists) participated in two reading sessions: in the first, brain metastases were detected using VISIBLE only; in the second, the results of the first session were comprehensively evaluated by adding AI-VISIBLE information. Sensitivity, diagnostic performance, and false positives/case were evaluated. Diagnostic performance was assessed using a figure-of-merit (FOM). Sensitivity and false positives/case were evaluated using McNemar and paired t-tests, respectively.</p><p><strong>Results: </strong>The McNemar test revealed a significant difference between VISIBLE with/without AI information (P < 0.0001). Significantly higher sensitivity (94.9 ± 1.7% vs. 88.3 ± 5.1%, P = 0.0028) and FOM (0.983 ± 0.009 vs. 0.972 ± 0.013, P = 0.0063) were achieved using VISIBLE with AI information vs. without. No significant difference was observed in false positives/case with and without AI information (0.23 ± 0.19 vs. 0.18 ± 0.15, P = 0.250). AI-assisted results of radiology residents became comparable to results of neuroradiologists (sensitivity, FOM: 85.9 ± 3.4% vs. 90.0 ± 5.9%, 0.969 ± 0.016 vs. 0.974 ± 0.012 without AI information; 94.8 ± 1.3% vs. 95.0 ± 2.1%, 0.977 ± 0.010 vs. 0.988 ± 0.005 with AI information, respectively).</p><p><strong>Conclusion: </strong>AI-VISIBLE improved the sensitivity and performance for diagnosing brain metastases.</p>\",\"PeriodicalId\":2,\"journal\":{\"name\":\"ACS Applied Bio Materials\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":4.6000,\"publicationDate\":\"2024-08-22\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"ACS Applied Bio Materials\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1007/s00234-024-03454-4\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"MATERIALS SCIENCE, BIOMATERIALS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"ACS Applied Bio Materials","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s00234-024-03454-4","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"MATERIALS SCIENCE, BIOMATERIALS","Score":null,"Total":0}
引用次数: 0

摘要

目的:验证人工智能辅助体积各向同性同步交错亮血/黑血检查(AI-VISIBLE)检测脑转移瘤的有效性:这项回顾性研究获得了本院审查委员会的批准,并免除了书面知情同意的要求。共纳入 40 名患者:有脑转移和无脑转移的患者各 20 例。七名独立观察员(三名放射科住院医师和四名神经放射科医师)参加了两次阅片会:第一次阅片会仅使用 VISIBLE 检测脑转移瘤;第二次阅片会通过添加 AI-VISIBLE 信息对第一次阅片会的结果进行综合评估。对灵敏度、诊断性能和假阳性/病例进行了评估。诊断性能是通过权数(FOM)来评估的。灵敏度和假阳性/病例分别采用 McNemar 检验和配对 t 检验进行评估:McNemar 检验显示,有人工智能信息的 VISIBLE 和没有人工智能信息的 VISIBLE 之间存在显著差异(P 结论:有人工智能信息的 VISIBLE 和没有人工智能信息的 VISIBLE 之间存在显著差异):AI-VISIBLE提高了诊断脑转移的灵敏度和性能。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

Artificial intelligence-assisted volume isotropic simultaneous interleaved bright- and black-blood examination for brain metastases.

Artificial intelligence-assisted volume isotropic simultaneous interleaved bright- and black-blood examination for brain metastases.

Purpose: To verify the effectiveness of artificial intelligence-assisted volume isotropic simultaneous interleaved bright-/black-blood examination (AI-VISIBLE) for detecting brain metastases.

Methods: This retrospective study was approved by our institutional review board and the requirement for written informed consent was waived. Forty patients were included: 20 patients with and without brain metastases each. Seven independent observers (three radiology residents and four neuroradiologists) participated in two reading sessions: in the first, brain metastases were detected using VISIBLE only; in the second, the results of the first session were comprehensively evaluated by adding AI-VISIBLE information. Sensitivity, diagnostic performance, and false positives/case were evaluated. Diagnostic performance was assessed using a figure-of-merit (FOM). Sensitivity and false positives/case were evaluated using McNemar and paired t-tests, respectively.

Results: The McNemar test revealed a significant difference between VISIBLE with/without AI information (P < 0.0001). Significantly higher sensitivity (94.9 ± 1.7% vs. 88.3 ± 5.1%, P = 0.0028) and FOM (0.983 ± 0.009 vs. 0.972 ± 0.013, P = 0.0063) were achieved using VISIBLE with AI information vs. without. No significant difference was observed in false positives/case with and without AI information (0.23 ± 0.19 vs. 0.18 ± 0.15, P = 0.250). AI-assisted results of radiology residents became comparable to results of neuroradiologists (sensitivity, FOM: 85.9 ± 3.4% vs. 90.0 ± 5.9%, 0.969 ± 0.016 vs. 0.974 ± 0.012 without AI information; 94.8 ± 1.3% vs. 95.0 ± 2.1%, 0.977 ± 0.010 vs. 0.988 ± 0.005 with AI information, respectively).

Conclusion: AI-VISIBLE improved the sensitivity and performance for diagnosing brain metastases.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
ACS Applied Bio Materials
ACS Applied Bio Materials Chemistry-Chemistry (all)
CiteScore
9.40
自引率
2.10%
发文量
464
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信