{"title":"利用 ME-GRE T2* 序列在兔子模型中进行 3 T 磁共振成像量化心脏铁超载","authors":"Linlin Liang, Fangyan Xiao, Meicheng Li, Fengming Xu, Fei Peng, Chaotian Luo, Cheng Tang, Peng Peng","doi":"10.1002/jmri.29534","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Myocardial iron overload can lead to myocardial dysfunction, muscle cell injury, and end-stage heart failure. The enhanced signal-to-noise ratio and technical advancements have made 3 T magnetic resonance imaging (MRI) more accessible in clinical settings. However, 3 T assessments for early diagnosis of myocardial iron overload are scarce.</p><p><strong>Purpose: </strong>To evaluate the feasibility of myocardial iron quantification using 3 T MRI in a rabbit model of iron overload.</p><p><strong>Study type: </strong>Animal model.</p><p><strong>Animal model: </strong>Overall, 40 male New Zealand white rabbits were categorized into control (N = 8; no treatment) and experimental (N = 32; weekly 200 mg/kg iron dextran injections) groups.</p><p><strong>Sequence: </strong>3 T MRI with multi-echo gradient echo (ME-GRE) T2* sequence.</p><p><strong>Assessment: </strong>Each week, two experimental rabbits were randomly selected for blood collection to determine serum iron (SI) levels; their tissue was harvested to assess myocardial and hepatic iron deposition.</p><p><strong>Statistical tests: </strong>Spearman's rank correlation tests were used to evaluate the correlations among R2*, cardiac iron concentration (CIC), liver iron concentration (LIC), total amount of iron injected, and SI levels. P ≤ 0.05 was considered statistically significant.</p><p><strong>Results: </strong>The myocardial T2* value in the experimental group was significantly lower than that of the control group. An excellent correlation was observed between R2* values and CIC (r = 0.854). CIC moderately correlated with LIC (r = 0.712) and the total amount of iron injected (r = 0.698). A strong correlation was observed between the total amount of iron injected and LIC (r = 0.866). SI levels poorly correlated with the total amount of iron injected (r = 0.205, P = 0.277) and LIC (r = 0.170, P = 0.370) but fairly correlated with CIC (r = 0.415, P = 0.022).</p><p><strong>Data conclusion: </strong>A 3 T MRI with an ME-GRE sequence may serve as a noninvasive method for evaluating cardiac iron content.</p><p><strong>Evidence level: </strong>N/A TECHNICAL EFFICACY: Stage 1.</p>","PeriodicalId":16140,"journal":{"name":"Journal of Magnetic Resonance Imaging","volume":null,"pages":null},"PeriodicalIF":3.3000,"publicationDate":"2024-08-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Quantification of Cardiac Iron Overload at 3 T MRI in a Rabbit Model Utilizing ME-GRE T2* Sequence.\",\"authors\":\"Linlin Liang, Fangyan Xiao, Meicheng Li, Fengming Xu, Fei Peng, Chaotian Luo, Cheng Tang, Peng Peng\",\"doi\":\"10.1002/jmri.29534\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>Myocardial iron overload can lead to myocardial dysfunction, muscle cell injury, and end-stage heart failure. The enhanced signal-to-noise ratio and technical advancements have made 3 T magnetic resonance imaging (MRI) more accessible in clinical settings. However, 3 T assessments for early diagnosis of myocardial iron overload are scarce.</p><p><strong>Purpose: </strong>To evaluate the feasibility of myocardial iron quantification using 3 T MRI in a rabbit model of iron overload.</p><p><strong>Study type: </strong>Animal model.</p><p><strong>Animal model: </strong>Overall, 40 male New Zealand white rabbits were categorized into control (N = 8; no treatment) and experimental (N = 32; weekly 200 mg/kg iron dextran injections) groups.</p><p><strong>Sequence: </strong>3 T MRI with multi-echo gradient echo (ME-GRE) T2* sequence.</p><p><strong>Assessment: </strong>Each week, two experimental rabbits were randomly selected for blood collection to determine serum iron (SI) levels; their tissue was harvested to assess myocardial and hepatic iron deposition.</p><p><strong>Statistical tests: </strong>Spearman's rank correlation tests were used to evaluate the correlations among R2*, cardiac iron concentration (CIC), liver iron concentration (LIC), total amount of iron injected, and SI levels. P ≤ 0.05 was considered statistically significant.</p><p><strong>Results: </strong>The myocardial T2* value in the experimental group was significantly lower than that of the control group. An excellent correlation was observed between R2* values and CIC (r = 0.854). CIC moderately correlated with LIC (r = 0.712) and the total amount of iron injected (r = 0.698). A strong correlation was observed between the total amount of iron injected and LIC (r = 0.866). SI levels poorly correlated with the total amount of iron injected (r = 0.205, P = 0.277) and LIC (r = 0.170, P = 0.370) but fairly correlated with CIC (r = 0.415, P = 0.022).</p><p><strong>Data conclusion: </strong>A 3 T MRI with an ME-GRE sequence may serve as a noninvasive method for evaluating cardiac iron content.</p><p><strong>Evidence level: </strong>N/A TECHNICAL EFFICACY: Stage 1.</p>\",\"PeriodicalId\":16140,\"journal\":{\"name\":\"Journal of Magnetic Resonance Imaging\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":3.3000,\"publicationDate\":\"2024-08-21\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Magnetic Resonance Imaging\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1002/jmri.29534\",\"RegionNum\":2,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Magnetic Resonance Imaging","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1002/jmri.29534","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
Quantification of Cardiac Iron Overload at 3 T MRI in a Rabbit Model Utilizing ME-GRE T2* Sequence.
Background: Myocardial iron overload can lead to myocardial dysfunction, muscle cell injury, and end-stage heart failure. The enhanced signal-to-noise ratio and technical advancements have made 3 T magnetic resonance imaging (MRI) more accessible in clinical settings. However, 3 T assessments for early diagnosis of myocardial iron overload are scarce.
Purpose: To evaluate the feasibility of myocardial iron quantification using 3 T MRI in a rabbit model of iron overload.
Study type: Animal model.
Animal model: Overall, 40 male New Zealand white rabbits were categorized into control (N = 8; no treatment) and experimental (N = 32; weekly 200 mg/kg iron dextran injections) groups.
Sequence: 3 T MRI with multi-echo gradient echo (ME-GRE) T2* sequence.
Assessment: Each week, two experimental rabbits were randomly selected for blood collection to determine serum iron (SI) levels; their tissue was harvested to assess myocardial and hepatic iron deposition.
Statistical tests: Spearman's rank correlation tests were used to evaluate the correlations among R2*, cardiac iron concentration (CIC), liver iron concentration (LIC), total amount of iron injected, and SI levels. P ≤ 0.05 was considered statistically significant.
Results: The myocardial T2* value in the experimental group was significantly lower than that of the control group. An excellent correlation was observed between R2* values and CIC (r = 0.854). CIC moderately correlated with LIC (r = 0.712) and the total amount of iron injected (r = 0.698). A strong correlation was observed between the total amount of iron injected and LIC (r = 0.866). SI levels poorly correlated with the total amount of iron injected (r = 0.205, P = 0.277) and LIC (r = 0.170, P = 0.370) but fairly correlated with CIC (r = 0.415, P = 0.022).
Data conclusion: A 3 T MRI with an ME-GRE sequence may serve as a noninvasive method for evaluating cardiac iron content.
期刊介绍:
The Journal of Magnetic Resonance Imaging (JMRI) is an international journal devoted to the timely publication of basic and clinical research, educational and review articles, and other information related to the diagnostic applications of magnetic resonance.