Luigi Asmundo, Moreno Zanardo, Massimo Cressoni, Federico Ambrogi, Luciano Bet, Fabio Giatsidis, Giovanni Di Leo, Francesco Sardanelli, Paolo Vitali
{"title":"急性中风时计算机断层扫描灌注(CTP)的缺血核心检测阈值。","authors":"Luigi Asmundo, Moreno Zanardo, Massimo Cressoni, Federico Ambrogi, Luciano Bet, Fabio Giatsidis, Giovanni Di Leo, Francesco Sardanelli, Paolo Vitali","doi":"10.1007/s11547-024-01868-x","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>This study aimed to determine the accuracy of detecting ischemic core volume using computed tomography perfusion (CTP) in patients with suspected acute ischemic stroke compared to diffusion-weighted magnetic resonance imaging (DW-MRI) as the reference standard.</p><p><strong>Methods: </strong>This retrospective monocentric study included patients who underwent CTP and DW-MRI for suspected acute ischemic stroke. The ischemic core size was measured at DW-MRI. The detectability threshold volume was defined as the lowest volume detected by each method. Clinical data on revascularization therapy, along with the clinical decision that influenced the choice, were collected. Volumes of the ischemic cores were compared using the Mann-Whitney U test.</p><p><strong>Results: </strong>Of 83 patients who underwent CTP, 52 patients (median age 73 years, IQR 63-80, 36 men) also had DW-MRI and were included, with a total of 70 ischemic cores. Regarding ischemic cores, only 18/70 (26%) were detected by both CTP and DW-MRI, while 52/70 (74%) were detected only by DW-MRI. The median volume of the 52 ischemic cores undetected on CTP (0.6 mL, IQR 0.2-1.3 mL) was significantly lower (p < 0.001) than that of the 18 ischemic cores detected on CTP (14.2 mL, IQR 7.0-18.4 mL). The smallest ischemic core detected on CTP had a volume of 5.0 mL. Among the 20 patients with undetected ischemic core on CTP, only 10% (2/20) received thrombolysis treatment.</p><p><strong>Conclusions: </strong>CTP maps failed in detecting ischemic cores smaller than 5 mL. DW-MRI remains essential for suspected small ischemic brain lesions to guide a correct treatment decision-making.</p>","PeriodicalId":20817,"journal":{"name":"Radiologia Medica","volume":" ","pages":"1522-1529"},"PeriodicalIF":9.7000,"publicationDate":"2024-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Ischemic core detection threshold of computed tomography perfusion (CTP) in acute stroke.\",\"authors\":\"Luigi Asmundo, Moreno Zanardo, Massimo Cressoni, Federico Ambrogi, Luciano Bet, Fabio Giatsidis, Giovanni Di Leo, Francesco Sardanelli, Paolo Vitali\",\"doi\":\"10.1007/s11547-024-01868-x\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>This study aimed to determine the accuracy of detecting ischemic core volume using computed tomography perfusion (CTP) in patients with suspected acute ischemic stroke compared to diffusion-weighted magnetic resonance imaging (DW-MRI) as the reference standard.</p><p><strong>Methods: </strong>This retrospective monocentric study included patients who underwent CTP and DW-MRI for suspected acute ischemic stroke. The ischemic core size was measured at DW-MRI. The detectability threshold volume was defined as the lowest volume detected by each method. Clinical data on revascularization therapy, along with the clinical decision that influenced the choice, were collected. Volumes of the ischemic cores were compared using the Mann-Whitney U test.</p><p><strong>Results: </strong>Of 83 patients who underwent CTP, 52 patients (median age 73 years, IQR 63-80, 36 men) also had DW-MRI and were included, with a total of 70 ischemic cores. Regarding ischemic cores, only 18/70 (26%) were detected by both CTP and DW-MRI, while 52/70 (74%) were detected only by DW-MRI. The median volume of the 52 ischemic cores undetected on CTP (0.6 mL, IQR 0.2-1.3 mL) was significantly lower (p < 0.001) than that of the 18 ischemic cores detected on CTP (14.2 mL, IQR 7.0-18.4 mL). The smallest ischemic core detected on CTP had a volume of 5.0 mL. Among the 20 patients with undetected ischemic core on CTP, only 10% (2/20) received thrombolysis treatment.</p><p><strong>Conclusions: </strong>CTP maps failed in detecting ischemic cores smaller than 5 mL. DW-MRI remains essential for suspected small ischemic brain lesions to guide a correct treatment decision-making.</p>\",\"PeriodicalId\":20817,\"journal\":{\"name\":\"Radiologia Medica\",\"volume\":\" \",\"pages\":\"1522-1529\"},\"PeriodicalIF\":9.7000,\"publicationDate\":\"2024-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Radiologia Medica\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1007/s11547-024-01868-x\",\"RegionNum\":1,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/8/20 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q1\",\"JCRName\":\"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Radiologia Medica","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s11547-024-01868-x","RegionNum":1,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/8/20 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
Ischemic core detection threshold of computed tomography perfusion (CTP) in acute stroke.
Purpose: This study aimed to determine the accuracy of detecting ischemic core volume using computed tomography perfusion (CTP) in patients with suspected acute ischemic stroke compared to diffusion-weighted magnetic resonance imaging (DW-MRI) as the reference standard.
Methods: This retrospective monocentric study included patients who underwent CTP and DW-MRI for suspected acute ischemic stroke. The ischemic core size was measured at DW-MRI. The detectability threshold volume was defined as the lowest volume detected by each method. Clinical data on revascularization therapy, along with the clinical decision that influenced the choice, were collected. Volumes of the ischemic cores were compared using the Mann-Whitney U test.
Results: Of 83 patients who underwent CTP, 52 patients (median age 73 years, IQR 63-80, 36 men) also had DW-MRI and were included, with a total of 70 ischemic cores. Regarding ischemic cores, only 18/70 (26%) were detected by both CTP and DW-MRI, while 52/70 (74%) were detected only by DW-MRI. The median volume of the 52 ischemic cores undetected on CTP (0.6 mL, IQR 0.2-1.3 mL) was significantly lower (p < 0.001) than that of the 18 ischemic cores detected on CTP (14.2 mL, IQR 7.0-18.4 mL). The smallest ischemic core detected on CTP had a volume of 5.0 mL. Among the 20 patients with undetected ischemic core on CTP, only 10% (2/20) received thrombolysis treatment.
Conclusions: CTP maps failed in detecting ischemic cores smaller than 5 mL. DW-MRI remains essential for suspected small ischemic brain lesions to guide a correct treatment decision-making.
期刊介绍:
Felice Perussia founded La radiologia medica in 1914. It is a peer-reviewed journal and serves as the official journal of the Italian Society of Medical and Interventional Radiology (SIRM). The primary purpose of the journal is to disseminate information related to Radiology, especially advancements in diagnostic imaging and related disciplines. La radiologia medica welcomes original research on both fundamental and clinical aspects of modern radiology, with a particular focus on diagnostic and interventional imaging techniques. It also covers topics such as radiotherapy, nuclear medicine, radiobiology, health physics, and artificial intelligence in the context of clinical implications. The journal includes various types of contributions such as original articles, review articles, editorials, short reports, and letters to the editor. With an esteemed Editorial Board and a selection of insightful reports, the journal is an indispensable resource for radiologists and professionals in related fields. Ultimately, La radiologia medica aims to serve as a platform for international collaboration and knowledge sharing within the radiological community.