{"title":"iCover球囊扩张型覆盖支架治疗髂动脉病变的短期疗效。","authors":"Murat Canyiğit, Muhammed Said Beşler","doi":"10.4274/dir.2024.242868","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To describe the short-term follow-up results of the recently introduced iCover balloon-expandable covered stents for iliac artery lesions.</p><p><strong>Methods: </strong>All consecutive patients treated with iCover balloon-expandable covered stents between March 2022 and August 2023 were retrospectively reviewed. The primary endpoint was target lesion revascularization (TLR) at 6 months. Secondary endpoints included major adverse events, freedom from TLR throughout the follow-up period, primary and secondary patency, and clinical and technical success.</p><p><strong>Results: </strong>In the study population of 40 adult patients (87.5% men, mean age: 63.5 ± 11 years), the mean follow-up period was 6.2 ± 2.8 months. A total of 98 stents of various sizes were implanted. The technical success rate was 100%. Freedom from TLR was 95.8% [95%, confidence interval (CI): 95%- 96.6%], the primary patency rate was 91.7% (95%, CI: 89.8%-93.6%), and the secondary patency rate was 95.8% (95%, CI: 95%-96.6%) at 6 months. The all-cause mortality rate was 5%.</p><p><strong>Conclusion: </strong>These real-world data demonstrate a high technical and clinical success rate, a high 6-month primary patency rate, and a low requirement for TLR. These are promising indicators for the safety and efficacy of iCover stents.</p><p><strong>Clinical significance: </strong>Balloon-expandable covered stents are frequently used in iliac artery atherosclerotic disease. This study shows that the short-term follow-up results of the new iCover stent are satisfactory, indicating its safety and efficacy.</p>","PeriodicalId":11341,"journal":{"name":"Diagnostic and interventional radiology","volume":null,"pages":null},"PeriodicalIF":1.4000,"publicationDate":"2024-08-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Short-term outcomes of the iCover balloon-expandable covered stent for iliac artery lesions.\",\"authors\":\"Murat Canyiğit, Muhammed Said Beşler\",\"doi\":\"10.4274/dir.2024.242868\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>To describe the short-term follow-up results of the recently introduced iCover balloon-expandable covered stents for iliac artery lesions.</p><p><strong>Methods: </strong>All consecutive patients treated with iCover balloon-expandable covered stents between March 2022 and August 2023 were retrospectively reviewed. The primary endpoint was target lesion revascularization (TLR) at 6 months. Secondary endpoints included major adverse events, freedom from TLR throughout the follow-up period, primary and secondary patency, and clinical and technical success.</p><p><strong>Results: </strong>In the study population of 40 adult patients (87.5% men, mean age: 63.5 ± 11 years), the mean follow-up period was 6.2 ± 2.8 months. A total of 98 stents of various sizes were implanted. The technical success rate was 100%. Freedom from TLR was 95.8% [95%, confidence interval (CI): 95%- 96.6%], the primary patency rate was 91.7% (95%, CI: 89.8%-93.6%), and the secondary patency rate was 95.8% (95%, CI: 95%-96.6%) at 6 months. The all-cause mortality rate was 5%.</p><p><strong>Conclusion: </strong>These real-world data demonstrate a high technical and clinical success rate, a high 6-month primary patency rate, and a low requirement for TLR. These are promising indicators for the safety and efficacy of iCover stents.</p><p><strong>Clinical significance: </strong>Balloon-expandable covered stents are frequently used in iliac artery atherosclerotic disease. This study shows that the short-term follow-up results of the new iCover stent are satisfactory, indicating its safety and efficacy.</p>\",\"PeriodicalId\":11341,\"journal\":{\"name\":\"Diagnostic and interventional radiology\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.4000,\"publicationDate\":\"2024-08-19\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Diagnostic and interventional radiology\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.4274/dir.2024.242868\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Diagnostic and interventional radiology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.4274/dir.2024.242868","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
Short-term outcomes of the iCover balloon-expandable covered stent for iliac artery lesions.
Purpose: To describe the short-term follow-up results of the recently introduced iCover balloon-expandable covered stents for iliac artery lesions.
Methods: All consecutive patients treated with iCover balloon-expandable covered stents between March 2022 and August 2023 were retrospectively reviewed. The primary endpoint was target lesion revascularization (TLR) at 6 months. Secondary endpoints included major adverse events, freedom from TLR throughout the follow-up period, primary and secondary patency, and clinical and technical success.
Results: In the study population of 40 adult patients (87.5% men, mean age: 63.5 ± 11 years), the mean follow-up period was 6.2 ± 2.8 months. A total of 98 stents of various sizes were implanted. The technical success rate was 100%. Freedom from TLR was 95.8% [95%, confidence interval (CI): 95%- 96.6%], the primary patency rate was 91.7% (95%, CI: 89.8%-93.6%), and the secondary patency rate was 95.8% (95%, CI: 95%-96.6%) at 6 months. The all-cause mortality rate was 5%.
Conclusion: These real-world data demonstrate a high technical and clinical success rate, a high 6-month primary patency rate, and a low requirement for TLR. These are promising indicators for the safety and efficacy of iCover stents.
Clinical significance: Balloon-expandable covered stents are frequently used in iliac artery atherosclerotic disease. This study shows that the short-term follow-up results of the new iCover stent are satisfactory, indicating its safety and efficacy.