{"title":"横风影响下撬装压缩天然气空气冷却器喷雾冷却的数值研究","authors":"","doi":"10.1016/j.ijrefrig.2024.07.025","DOIUrl":null,"url":null,"abstract":"<div><p>Air cooler is a critical heat dissipation equipment applied in the field of oil and gas storage, which is mainly used to control the temperature during oil and gas storage and ensure the safety of oil and gas storage. After the installation of the spray cooling system on the skid-mounted compressed natural gas (CNG) air cooler Suqiao gas storage, the inlet air temperature of the air cooler decreases, resulting in reduced compressor power consumption. This effectively addresses the issue of unit shutdown due to high temperatures during the summer. However, the actual spray effect on-site reveals the impact of crosswinds, which poses a challenge. In this study, the flow field and causes of the skid-mounted CNG air cooler equipped with a spray cooling system under the influence of crosswinds are analyzed. Additionally, a solution involving the installation of a baffle is proposed. The results highlight that crosswinds have an adverse effect on outdoor spray cooling. With the installation of the baffle, the low-temperature area expands, resulting in lower temperatures. The cooling range is approximately 2 K, effectively counteracting the negative effects of crosswinds.</p></div>","PeriodicalId":14274,"journal":{"name":"International Journal of Refrigeration-revue Internationale Du Froid","volume":null,"pages":null},"PeriodicalIF":3.5000,"publicationDate":"2024-07-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Numerical investigation on spray cooling of skid-mounted CNG air cooler under the influence of crosswind\",\"authors\":\"\",\"doi\":\"10.1016/j.ijrefrig.2024.07.025\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>Air cooler is a critical heat dissipation equipment applied in the field of oil and gas storage, which is mainly used to control the temperature during oil and gas storage and ensure the safety of oil and gas storage. After the installation of the spray cooling system on the skid-mounted compressed natural gas (CNG) air cooler Suqiao gas storage, the inlet air temperature of the air cooler decreases, resulting in reduced compressor power consumption. This effectively addresses the issue of unit shutdown due to high temperatures during the summer. However, the actual spray effect on-site reveals the impact of crosswinds, which poses a challenge. In this study, the flow field and causes of the skid-mounted CNG air cooler equipped with a spray cooling system under the influence of crosswinds are analyzed. Additionally, a solution involving the installation of a baffle is proposed. The results highlight that crosswinds have an adverse effect on outdoor spray cooling. With the installation of the baffle, the low-temperature area expands, resulting in lower temperatures. The cooling range is approximately 2 K, effectively counteracting the negative effects of crosswinds.</p></div>\",\"PeriodicalId\":14274,\"journal\":{\"name\":\"International Journal of Refrigeration-revue Internationale Du Froid\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":3.5000,\"publicationDate\":\"2024-07-29\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Journal of Refrigeration-revue Internationale Du Froid\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S0140700724002652\",\"RegionNum\":2,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"ENGINEERING, MECHANICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Refrigeration-revue Internationale Du Froid","FirstCategoryId":"5","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0140700724002652","RegionNum":2,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ENGINEERING, MECHANICAL","Score":null,"Total":0}
引用次数: 0

摘要

空气冷却器是应用于油气储藏领域的关键散热设备,主要用于控制油气储藏过程中的温度,确保油气储藏安全。苏桥储气库撬装式压缩天然气(CNG)空冷器安装喷雾冷却系统后,空冷器进气温度降低,压缩机耗电量减少。这有效解决了夏季高温导致机组停机的问题。然而,现场实际喷淋效果却显示出了横风的影响,这给研究带来了挑战。本研究分析了配备喷雾冷却系统的撬装压缩天然气空气冷却器在横风影响下的流场和原因。此外,还提出了安装挡板的解决方案。结果表明,横风对室外喷雾冷却有不利影响。安装挡板后,低温区域扩大,温度降低。冷却范围约为 2 K,有效抵消了横风的负面影响。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Numerical investigation on spray cooling of skid-mounted CNG air cooler under the influence of crosswind

Air cooler is a critical heat dissipation equipment applied in the field of oil and gas storage, which is mainly used to control the temperature during oil and gas storage and ensure the safety of oil and gas storage. After the installation of the spray cooling system on the skid-mounted compressed natural gas (CNG) air cooler Suqiao gas storage, the inlet air temperature of the air cooler decreases, resulting in reduced compressor power consumption. This effectively addresses the issue of unit shutdown due to high temperatures during the summer. However, the actual spray effect on-site reveals the impact of crosswinds, which poses a challenge. In this study, the flow field and causes of the skid-mounted CNG air cooler equipped with a spray cooling system under the influence of crosswinds are analyzed. Additionally, a solution involving the installation of a baffle is proposed. The results highlight that crosswinds have an adverse effect on outdoor spray cooling. With the installation of the baffle, the low-temperature area expands, resulting in lower temperatures. The cooling range is approximately 2 K, effectively counteracting the negative effects of crosswinds.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
7.30
自引率
12.80%
发文量
363
审稿时长
3.7 months
期刊介绍: The International Journal of Refrigeration is published for the International Institute of Refrigeration (IIR) by Elsevier. It is essential reading for all those wishing to keep abreast of research and industrial news in refrigeration, air conditioning and associated fields. This is particularly important in these times of rapid introduction of alternative refrigerants and the emergence of new technology. The journal has published special issues on alternative refrigerants and novel topics in the field of boiling, condensation, heat pumps, food refrigeration, carbon dioxide, ammonia, hydrocarbons, magnetic refrigeration at room temperature, sorptive cooling, phase change materials and slurries, ejector technology, compressors, and solar cooling. As well as original research papers the International Journal of Refrigeration also includes review articles, papers presented at IIR conferences, short reports and letters describing preliminary results and experimental details, and letters to the Editor on recent areas of discussion and controversy. Other features include forthcoming events, conference reports and book reviews. Papers are published in either English or French with the IIR news section in both languages.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信