Ernesto Mejia, Ryan A Leahy, Jenny E Zablah, Gareth J Morgan
{"title":"使用定制的伸缩式支架复合体经皮治疗残余上窦静脉缺损。","authors":"Ernesto Mejia, Ryan A Leahy, Jenny E Zablah, Gareth J Morgan","doi":"10.1002/ccd.31188","DOIUrl":null,"url":null,"abstract":"<p><p>The management of superior sinus venosus defects (SVD) via transcatheter covered stent (CS) placement is becoming an acceptable alternative to open heart surgery. Though the medium-term success of this procedure has been described, residual shunting from damage to the covering of the implanted stents, use of stents which are too short and unanticipated shortening of stents may result in immediate or short-term procedural failure. In such cases, placement of a second CS may be required to address a residual defect. Preprocedural prediction of the length of stent required for residual leak treatment may not be as accurate as predicting the required stent length in a native defect, meaning that compassionate use applications to facilitate acquiring non-standard stent and balloon combinations may not be practical. We present a successful case of residual SVD closure using a novel sutured telescoping stent technique. Further collaboration with industry should encourage regulatory approval of longer CS, to mitigate the need for potentially unpredictable modifications such as this.</p>","PeriodicalId":9650,"journal":{"name":"Catheterization and Cardiovascular Interventions","volume":null,"pages":null},"PeriodicalIF":2.1000,"publicationDate":"2024-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Using a customized telescoped stent complex in the percutaneous treatment of a residual superior sinus venosus defect.\",\"authors\":\"Ernesto Mejia, Ryan A Leahy, Jenny E Zablah, Gareth J Morgan\",\"doi\":\"10.1002/ccd.31188\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The management of superior sinus venosus defects (SVD) via transcatheter covered stent (CS) placement is becoming an acceptable alternative to open heart surgery. Though the medium-term success of this procedure has been described, residual shunting from damage to the covering of the implanted stents, use of stents which are too short and unanticipated shortening of stents may result in immediate or short-term procedural failure. In such cases, placement of a second CS may be required to address a residual defect. Preprocedural prediction of the length of stent required for residual leak treatment may not be as accurate as predicting the required stent length in a native defect, meaning that compassionate use applications to facilitate acquiring non-standard stent and balloon combinations may not be practical. We present a successful case of residual SVD closure using a novel sutured telescoping stent technique. Further collaboration with industry should encourage regulatory approval of longer CS, to mitigate the need for potentially unpredictable modifications such as this.</p>\",\"PeriodicalId\":9650,\"journal\":{\"name\":\"Catheterization and Cardiovascular Interventions\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":2.1000,\"publicationDate\":\"2024-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Catheterization and Cardiovascular Interventions\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1002/ccd.31188\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/8/15 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q3\",\"JCRName\":\"CARDIAC & CARDIOVASCULAR SYSTEMS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Catheterization and Cardiovascular Interventions","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1002/ccd.31188","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/8/15 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
Using a customized telescoped stent complex in the percutaneous treatment of a residual superior sinus venosus defect.
The management of superior sinus venosus defects (SVD) via transcatheter covered stent (CS) placement is becoming an acceptable alternative to open heart surgery. Though the medium-term success of this procedure has been described, residual shunting from damage to the covering of the implanted stents, use of stents which are too short and unanticipated shortening of stents may result in immediate or short-term procedural failure. In such cases, placement of a second CS may be required to address a residual defect. Preprocedural prediction of the length of stent required for residual leak treatment may not be as accurate as predicting the required stent length in a native defect, meaning that compassionate use applications to facilitate acquiring non-standard stent and balloon combinations may not be practical. We present a successful case of residual SVD closure using a novel sutured telescoping stent technique. Further collaboration with industry should encourage regulatory approval of longer CS, to mitigate the need for potentially unpredictable modifications such as this.
期刊介绍:
Catheterization and Cardiovascular Interventions is an international journal covering the broad field of cardiovascular diseases. Subject material includes basic and clinical information that is derived from or related to invasive and interventional coronary or peripheral vascular techniques. The journal focuses on material that will be of immediate practical value to physicians providing patient care in the clinical laboratory setting. To accomplish this, the journal publishes Preliminary Reports and Work In Progress articles that complement the traditional Original Studies, Case Reports, and Comprehensive Reviews. Perspective and insight concerning controversial subjects and evolving technologies are provided regularly through Editorial Commentaries furnished by members of the Editorial Board and other experts. Articles are subject to double-blind peer review and complete editorial evaluation prior to any decision regarding acceptability.