{"title":"评估剂量限制规定变更前后介入心脏病学医生的晶状体辐射剂量。","authors":"Kodai Sagehashi, Yoshihiro Haga, Saki Takahira, Mako Tanabe, Mio Nakamura, Masahiro Sota, Yuji Kaga, Mitsuya Abe, Norio Tada, Koichi Chida","doi":"10.1088/1361-6498/ad6f19","DOIUrl":null,"url":null,"abstract":"<p><p>In response to the International Commission on Radiological Protection, which lowered the lens equivalent dose limit, Japan lowered the lens dose limit from 150 mSv y<sup>-1</sup>to 100 mSv/5 years and 50 mSv y<sup>-1</sup>, with this new rule taking effect on 1 April 2021. DOSIRIS<sup>®</sup>is a dosimeter that can accurately measure lens dose. Herein, we investigated lens dose in interventional cardiology physicians 1 year before and after the reduction of the lens dose limit using a neck dosimeter and lens dosimeter measurements. With an increase in the number of cases, both personal dose equivalent at 0.07 mm depth [Hp(0.07), neck dosimeter] and personal dose equivalent at 3 mm depth [Hp(3), lens dosimeter] increased for most of the physicians. The Hp(3) of the lens considering the shielding effect of the Pb glasses using lens dosimeter exceeded 20 mSv y<sup>-1</sup>for two of the 14 physicians. Protection from radiation dose will become even more important in the future, as these two physicians may experience radiation dose exceeding 100 mSv/5 years. The average dose per procedure increased, but not significantly. There was a strong correlation between the neck dosimeter and lens dosimeter scores, although there was no significant change before and after the lens dose limit was lowered. This correlation was particularly strong for physicians who primarily treated patients. As such, it is possible to infer accurate lens doses from neck doses in physicians who primarily perform diagnostics. However, it is desirable to use a dosimeter that can directly measure Hp(3) because of the high lens dose.</p>","PeriodicalId":50068,"journal":{"name":"Journal of Radiological Protection","volume":" ","pages":""},"PeriodicalIF":1.4000,"publicationDate":"2024-09-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Evaluation of radiation dose to the lens in interventional cardiology physicians before and after dose limit regulation changes.\",\"authors\":\"Kodai Sagehashi, Yoshihiro Haga, Saki Takahira, Mako Tanabe, Mio Nakamura, Masahiro Sota, Yuji Kaga, Mitsuya Abe, Norio Tada, Koichi Chida\",\"doi\":\"10.1088/1361-6498/ad6f19\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>In response to the International Commission on Radiological Protection, which lowered the lens equivalent dose limit, Japan lowered the lens dose limit from 150 mSv y<sup>-1</sup>to 100 mSv/5 years and 50 mSv y<sup>-1</sup>, with this new rule taking effect on 1 April 2021. DOSIRIS<sup>®</sup>is a dosimeter that can accurately measure lens dose. Herein, we investigated lens dose in interventional cardiology physicians 1 year before and after the reduction of the lens dose limit using a neck dosimeter and lens dosimeter measurements. With an increase in the number of cases, both personal dose equivalent at 0.07 mm depth [Hp(0.07), neck dosimeter] and personal dose equivalent at 3 mm depth [Hp(3), lens dosimeter] increased for most of the physicians. The Hp(3) of the lens considering the shielding effect of the Pb glasses using lens dosimeter exceeded 20 mSv y<sup>-1</sup>for two of the 14 physicians. Protection from radiation dose will become even more important in the future, as these two physicians may experience radiation dose exceeding 100 mSv/5 years. The average dose per procedure increased, but not significantly. There was a strong correlation between the neck dosimeter and lens dosimeter scores, although there was no significant change before and after the lens dose limit was lowered. This correlation was particularly strong for physicians who primarily treated patients. As such, it is possible to infer accurate lens doses from neck doses in physicians who primarily perform diagnostics. However, it is desirable to use a dosimeter that can directly measure Hp(3) because of the high lens dose.</p>\",\"PeriodicalId\":50068,\"journal\":{\"name\":\"Journal of Radiological Protection\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":1.4000,\"publicationDate\":\"2024-09-02\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Radiological Protection\",\"FirstCategoryId\":\"93\",\"ListUrlMain\":\"https://doi.org/10.1088/1361-6498/ad6f19\",\"RegionNum\":4,\"RegionCategory\":\"环境科学与生态学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"ENVIRONMENTAL SCIENCES\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Radiological Protection","FirstCategoryId":"93","ListUrlMain":"https://doi.org/10.1088/1361-6498/ad6f19","RegionNum":4,"RegionCategory":"环境科学与生态学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ENVIRONMENTAL SCIENCES","Score":null,"Total":0}
Evaluation of radiation dose to the lens in interventional cardiology physicians before and after dose limit regulation changes.
In response to the International Commission on Radiological Protection, which lowered the lens equivalent dose limit, Japan lowered the lens dose limit from 150 mSv y-1to 100 mSv/5 years and 50 mSv y-1, with this new rule taking effect on 1 April 2021. DOSIRIS®is a dosimeter that can accurately measure lens dose. Herein, we investigated lens dose in interventional cardiology physicians 1 year before and after the reduction of the lens dose limit using a neck dosimeter and lens dosimeter measurements. With an increase in the number of cases, both personal dose equivalent at 0.07 mm depth [Hp(0.07), neck dosimeter] and personal dose equivalent at 3 mm depth [Hp(3), lens dosimeter] increased for most of the physicians. The Hp(3) of the lens considering the shielding effect of the Pb glasses using lens dosimeter exceeded 20 mSv y-1for two of the 14 physicians. Protection from radiation dose will become even more important in the future, as these two physicians may experience radiation dose exceeding 100 mSv/5 years. The average dose per procedure increased, but not significantly. There was a strong correlation between the neck dosimeter and lens dosimeter scores, although there was no significant change before and after the lens dose limit was lowered. This correlation was particularly strong for physicians who primarily treated patients. As such, it is possible to infer accurate lens doses from neck doses in physicians who primarily perform diagnostics. However, it is desirable to use a dosimeter that can directly measure Hp(3) because of the high lens dose.
期刊介绍:
Journal of Radiological Protection publishes articles on all aspects of radiological protection, including non-ionising as well as ionising radiations. Fields of interest range from research, development and theory to operational matters, education and training. The very wide spectrum of its topics includes: dosimetry, instrument development, specialized measuring techniques, epidemiology, biological effects (in vivo and in vitro) and risk and environmental impact assessments.
The journal encourages publication of data and code as well as results.