基于任务的神经网络评估:基于人类观察者信号检测评估欠采样磁共振成像重建。

IF 16.4 1区 化学 Q1 CHEMISTRY, MULTIDISCIPLINARY
Accounts of Chemical Research Pub Date : 2024-07-01 Epub Date: 2024-08-13 DOI:10.1117/1.JMI.11.4.045503
Joshua D Herman, Rachel E Roca, Alexandra G O'Neill, Marcus L Wong, Sajan Goud Lingala, Angel R Pineda
{"title":"基于任务的神经网络评估:基于人类观察者信号检测评估欠采样磁共振成像重建。","authors":"Joshua D Herman, Rachel E Roca, Alexandra G O'Neill, Marcus L Wong, Sajan Goud Lingala, Angel R Pineda","doi":"10.1117/1.JMI.11.4.045503","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>Recent research explores using neural networks to reconstruct undersampled magnetic resonance imaging. Because of the complexity of the artifacts in the reconstructed images, there is a need to develop task-based approaches to image quality. We compared conventional global quantitative metrics to evaluate image quality in undersampled images generated by a neural network with human observer performance in a detection task. The purpose is to study which acceleration (2×, 3×, 4×, 5×) would be chosen with the conventional metrics and compare it to the acceleration chosen by human observer performance.</p><p><strong>Approach: </strong>We used common global metrics for evaluating image quality: the normalized root mean squared error (NRMSE) and structural similarity (SSIM). These metrics are compared with a measure of image quality that incorporates a subtle signal for a specific task to allow for image quality assessment that locally evaluates the effect of undersampling on a signal. We used a U-Net to reconstruct under-sampled images with 2×, 3×, 4×, and 5× one-dimensional undersampling rates. Cross-validation was performed for a 500- and a 4000-image training set with both SSIM and MSE losses. A two-alternative forced choice (2-AFC) observer study was carried out for detecting a subtle signal (small blurred disk) from images with the 4000-image training set.</p><p><strong>Results: </strong>We found that for both loss functions, the human observer performance on the 2-AFC studies led to a choice of a 2× undersampling, but the SSIM and NRMSE led to a choice of a 3× undersampling.</p><p><strong>Conclusions: </strong>For this detection task using a subtle small signal at the edge of detectability, SSIM and NRMSE led to an overestimate of the achievable undersampling using a U-Net before a steep loss of image quality between 2×, 3×, 4×, 5× undersampling rates when compared to the performance of human observers in the detection task.</p>","PeriodicalId":1,"journal":{"name":"Accounts of Chemical Research","volume":null,"pages":null},"PeriodicalIF":16.4000,"publicationDate":"2024-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11321363/pdf/","citationCount":"0","resultStr":"{\"title\":\"Task-based assessment for neural networks: evaluating undersampled MRI reconstructions based on human observer signal detection.\",\"authors\":\"Joshua D Herman, Rachel E Roca, Alexandra G O'Neill, Marcus L Wong, Sajan Goud Lingala, Angel R Pineda\",\"doi\":\"10.1117/1.JMI.11.4.045503\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>Recent research explores using neural networks to reconstruct undersampled magnetic resonance imaging. Because of the complexity of the artifacts in the reconstructed images, there is a need to develop task-based approaches to image quality. We compared conventional global quantitative metrics to evaluate image quality in undersampled images generated by a neural network with human observer performance in a detection task. The purpose is to study which acceleration (2×, 3×, 4×, 5×) would be chosen with the conventional metrics and compare it to the acceleration chosen by human observer performance.</p><p><strong>Approach: </strong>We used common global metrics for evaluating image quality: the normalized root mean squared error (NRMSE) and structural similarity (SSIM). These metrics are compared with a measure of image quality that incorporates a subtle signal for a specific task to allow for image quality assessment that locally evaluates the effect of undersampling on a signal. We used a U-Net to reconstruct under-sampled images with 2×, 3×, 4×, and 5× one-dimensional undersampling rates. Cross-validation was performed for a 500- and a 4000-image training set with both SSIM and MSE losses. A two-alternative forced choice (2-AFC) observer study was carried out for detecting a subtle signal (small blurred disk) from images with the 4000-image training set.</p><p><strong>Results: </strong>We found that for both loss functions, the human observer performance on the 2-AFC studies led to a choice of a 2× undersampling, but the SSIM and NRMSE led to a choice of a 3× undersampling.</p><p><strong>Conclusions: </strong>For this detection task using a subtle small signal at the edge of detectability, SSIM and NRMSE led to an overestimate of the achievable undersampling using a U-Net before a steep loss of image quality between 2×, 3×, 4×, 5× undersampling rates when compared to the performance of human observers in the detection task.</p>\",\"PeriodicalId\":1,\"journal\":{\"name\":\"Accounts of Chemical Research\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":16.4000,\"publicationDate\":\"2024-07-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11321363/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Accounts of Chemical Research\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1117/1.JMI.11.4.045503\",\"RegionNum\":1,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/8/13 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q1\",\"JCRName\":\"CHEMISTRY, MULTIDISCIPLINARY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Accounts of Chemical Research","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1117/1.JMI.11.4.045503","RegionNum":1,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/8/13 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"CHEMISTRY, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 0

摘要

研究目的最近的研究探索利用神经网络重建欠采样磁共振成像。由于重建图像中伪影的复杂性,需要开发基于任务的图像质量方法。我们将神经网络生成的欠采样图像中用于评估图像质量的传统全局定量指标与人类观察者在检测任务中的表现进行了比较。目的是研究传统指标会选择哪种加速度(2 倍、3 倍、4 倍、5 倍),并将其与人类观察者表现所选择的加速度进行比较:我们使用常见的全局指标来评估图像质量:归一化均方根误差 (NRMSE) 和结构相似性 (SSIM)。我们将这些指标与一种图像质量度量方法进行了比较,该方法结合了特定任务的微妙信号,可在局部评估欠采样对信号的影响,从而进行图像质量评估。我们使用 U-Net 重构欠采样图像,欠采样率分别为 2 倍、3 倍、4 倍和 5 倍。我们使用 SSIM 和 MSE 损失对 500 和 4000 图像训练集进行了交叉验证。在使用 4000 张图像训练集检测图像中的微弱信号(模糊的小圆盘)时,进行了双备选强制选择(2-AFC)观察者研究:结果:我们发现,对于两种损失函数,人类观察者在 2-AFC 研究中的表现都导致选择 2 倍的欠采样,但 SSIM 和 NRMSE 则导致选择 3 倍的欠采样:结论:与人类观察者在检测任务中的表现相比,在使用处于可检测边缘的微妙小信号的检测任务中,SSIM 和 NRMSE 会导致在 2 倍、3 倍、4 倍和 5 倍下采样率之间图像质量急剧下降之前,使用 U-Net 高估可实现的下采样率。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Task-based assessment for neural networks: evaluating undersampled MRI reconstructions based on human observer signal detection.

Purpose: Recent research explores using neural networks to reconstruct undersampled magnetic resonance imaging. Because of the complexity of the artifacts in the reconstructed images, there is a need to develop task-based approaches to image quality. We compared conventional global quantitative metrics to evaluate image quality in undersampled images generated by a neural network with human observer performance in a detection task. The purpose is to study which acceleration (2×, 3×, 4×, 5×) would be chosen with the conventional metrics and compare it to the acceleration chosen by human observer performance.

Approach: We used common global metrics for evaluating image quality: the normalized root mean squared error (NRMSE) and structural similarity (SSIM). These metrics are compared with a measure of image quality that incorporates a subtle signal for a specific task to allow for image quality assessment that locally evaluates the effect of undersampling on a signal. We used a U-Net to reconstruct under-sampled images with 2×, 3×, 4×, and 5× one-dimensional undersampling rates. Cross-validation was performed for a 500- and a 4000-image training set with both SSIM and MSE losses. A two-alternative forced choice (2-AFC) observer study was carried out for detecting a subtle signal (small blurred disk) from images with the 4000-image training set.

Results: We found that for both loss functions, the human observer performance on the 2-AFC studies led to a choice of a 2× undersampling, but the SSIM and NRMSE led to a choice of a 3× undersampling.

Conclusions: For this detection task using a subtle small signal at the edge of detectability, SSIM and NRMSE led to an overestimate of the achievable undersampling using a U-Net before a steep loss of image quality between 2×, 3×, 4×, 5× undersampling rates when compared to the performance of human observers in the detection task.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Accounts of Chemical Research
Accounts of Chemical Research 化学-化学综合
CiteScore
31.40
自引率
1.10%
发文量
312
审稿时长
2 months
期刊介绍: Accounts of Chemical Research presents short, concise and critical articles offering easy-to-read overviews of basic research and applications in all areas of chemistry and biochemistry. These short reviews focus on research from the author’s own laboratory and are designed to teach the reader about a research project. In addition, Accounts of Chemical Research publishes commentaries that give an informed opinion on a current research problem. Special Issues online are devoted to a single topic of unusual activity and significance. Accounts of Chemical Research replaces the traditional article abstract with an article "Conspectus." These entries synopsize the research affording the reader a closer look at the content and significance of an article. Through this provision of a more detailed description of the article contents, the Conspectus enhances the article's discoverability by search engines and the exposure for the research.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信