{"title":"从骨盆腔内突出的髋关节中取出断裂的导丝:罕见病例报告。","authors":"Vinay Prabhat, Kamlesh Kumar, Kumar Gaurav, Rohit Topno","doi":"10.4103/aam.aam_51_24","DOIUrl":null,"url":null,"abstract":"<p><p>Hardware breakage in the form of guide wire or drill bit is a devastating complication particularly if occurs around hip joint during cephalo-medullary nailing. It should be removed on urgent basis as it can migrate to the pelvic cavity and damages adjacent neuro-vascular bundle and visceral organ immediately as well joint arthritis later on. There are very few cases report available in the literature with retrieval techniques by using disc forceps, pituitary forceps, oversized reamers, arthrotomy with joint dislocation and through ilioinguinal approaches occasionally. We are presenting an interesting and rare case of broken guide wire inside hip joint protruding into the pelvic cavity which got retrieved through lower midline open laparotomy approach.</p>","PeriodicalId":7938,"journal":{"name":"Annals of African Medicine","volume":" ","pages":"737-739"},"PeriodicalIF":0.6000,"publicationDate":"2024-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11556483/pdf/","citationCount":"0","resultStr":"{\"title\":\"Retrieval of Broken Guidewire from the Hip Joint Protruding inside the Pelvic Cavity: A Rare Case Report.\",\"authors\":\"Vinay Prabhat, Kamlesh Kumar, Kumar Gaurav, Rohit Topno\",\"doi\":\"10.4103/aam.aam_51_24\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Hardware breakage in the form of guide wire or drill bit is a devastating complication particularly if occurs around hip joint during cephalo-medullary nailing. It should be removed on urgent basis as it can migrate to the pelvic cavity and damages adjacent neuro-vascular bundle and visceral organ immediately as well joint arthritis later on. There are very few cases report available in the literature with retrieval techniques by using disc forceps, pituitary forceps, oversized reamers, arthrotomy with joint dislocation and through ilioinguinal approaches occasionally. We are presenting an interesting and rare case of broken guide wire inside hip joint protruding into the pelvic cavity which got retrieved through lower midline open laparotomy approach.</p>\",\"PeriodicalId\":7938,\"journal\":{\"name\":\"Annals of African Medicine\",\"volume\":\" \",\"pages\":\"737-739\"},\"PeriodicalIF\":0.6000,\"publicationDate\":\"2024-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11556483/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Annals of African Medicine\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.4103/aam.aam_51_24\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/8/13 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q3\",\"JCRName\":\"MEDICINE, GENERAL & INTERNAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Annals of African Medicine","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4103/aam.aam_51_24","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/8/13 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"MEDICINE, GENERAL & INTERNAL","Score":null,"Total":0}
Retrieval of Broken Guidewire from the Hip Joint Protruding inside the Pelvic Cavity: A Rare Case Report.
Hardware breakage in the form of guide wire or drill bit is a devastating complication particularly if occurs around hip joint during cephalo-medullary nailing. It should be removed on urgent basis as it can migrate to the pelvic cavity and damages adjacent neuro-vascular bundle and visceral organ immediately as well joint arthritis later on. There are very few cases report available in the literature with retrieval techniques by using disc forceps, pituitary forceps, oversized reamers, arthrotomy with joint dislocation and through ilioinguinal approaches occasionally. We are presenting an interesting and rare case of broken guide wire inside hip joint protruding into the pelvic cavity which got retrieved through lower midline open laparotomy approach.
期刊介绍:
The Annals of African Medicine is published by the Usmanu Danfodiyo University Teaching Hospital, Sokoto, Nigeria and the Annals of African Medicine Society. The Journal is intended to serve as a medium for the publication of research findings in the broad field of Medicine in Africa and other developing countries, and elsewhere which have relevance to Africa. It will serve as a source of information on the state of the art of Medicine in Africa, for continuing education for doctors in Africa and other developing countries, and also for the publication of meetings and conferences. The journal will publish articles I any field of Medicine and other fields which have relevance or implications for Medicine.