使用多台测试仪对阵列天线进行非接触式无源互调测量时的系统残余噪声降低技术

IF 0.3 Q4 ENGINEERING, ELECTRICAL & ELECTRONIC
Iori Serizawa;Nobuhiro Kuga
{"title":"使用多台测试仪对阵列天线进行非接触式无源互调测量时的系统残余噪声降低技术","authors":"Iori Serizawa;Nobuhiro Kuga","doi":"10.23919/comex.2024XBL0057","DOIUrl":null,"url":null,"abstract":"This letter proposes a concept of residual noise reduction when using multiple testers for non-contact passive intermodulation (PIM) measurements with near field sensing for array antennas. As described herein, the harmonic balance method and the finite difference time domain method are used for simulation. Examination is conducted for third-order PIMs in two-tone testing in the 2 GHz band. Simulation results indicate that the PIM noise which is weaker than the residual PIM of each tester becomes detectable when using the proposed method. The concept is validated further through experimentation using an equivalent array circuit in the 2 GHz band.","PeriodicalId":54101,"journal":{"name":"IEICE Communications Express","volume":"13 8","pages":"335-338"},"PeriodicalIF":0.3000,"publicationDate":"2024-06-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=10554807","citationCount":"0","resultStr":"{\"title\":\"System Residual Noise Reduction for Non-Contact Passive Intermodulation Measurements of Array Antennas Using Multiple Testers\",\"authors\":\"Iori Serizawa;Nobuhiro Kuga\",\"doi\":\"10.23919/comex.2024XBL0057\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This letter proposes a concept of residual noise reduction when using multiple testers for non-contact passive intermodulation (PIM) measurements with near field sensing for array antennas. As described herein, the harmonic balance method and the finite difference time domain method are used for simulation. Examination is conducted for third-order PIMs in two-tone testing in the 2 GHz band. Simulation results indicate that the PIM noise which is weaker than the residual PIM of each tester becomes detectable when using the proposed method. The concept is validated further through experimentation using an equivalent array circuit in the 2 GHz band.\",\"PeriodicalId\":54101,\"journal\":{\"name\":\"IEICE Communications Express\",\"volume\":\"13 8\",\"pages\":\"335-338\"},\"PeriodicalIF\":0.3000,\"publicationDate\":\"2024-06-11\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=10554807\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"IEICE Communications Express\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://ieeexplore.ieee.org/document/10554807/\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"ENGINEERING, ELECTRICAL & ELECTRONIC\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEICE Communications Express","FirstCategoryId":"1085","ListUrlMain":"https://ieeexplore.ieee.org/document/10554807/","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
引用次数: 0

摘要

本文提出了在使用多台测试仪对阵列天线进行非接触式被动互调(PIM)测量时,利用近场传感降低残余噪声的概念。如本文所述,模拟中使用了谐波平衡法和有限差分时域法。在 2 GHz 频段的双音频测试中对三阶 PIM 进行了检验。仿真结果表明,在使用建议的方法时,比每个测试仪的残余 PIM 更弱的 PIM 噪声也能被检测到。通过在 2 GHz 频段使用等效阵列电路进行实验,进一步验证了这一概念。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
System Residual Noise Reduction for Non-Contact Passive Intermodulation Measurements of Array Antennas Using Multiple Testers
This letter proposes a concept of residual noise reduction when using multiple testers for non-contact passive intermodulation (PIM) measurements with near field sensing for array antennas. As described herein, the harmonic balance method and the finite difference time domain method are used for simulation. Examination is conducted for third-order PIMs in two-tone testing in the 2 GHz band. Simulation results indicate that the PIM noise which is weaker than the residual PIM of each tester becomes detectable when using the proposed method. The concept is validated further through experimentation using an equivalent array circuit in the 2 GHz band.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
IEICE Communications Express
IEICE Communications Express ENGINEERING, ELECTRICAL & ELECTRONIC-
自引率
33.30%
发文量
114
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信