{"title":"对采用不同建筑方向快速制造的商用纯钛扣疲劳寿命进行有限元分析。","authors":"Kento Odaka, Mikiya Sugano, Taichi Kawamoto, Naoki Takano, Satoru Matsunaga","doi":"10.4012/dmj.2024-023","DOIUrl":null,"url":null,"abstract":"<p><p>The geometrical accuracy of additively manufactured pure titanium clasps depends on the building orientation. The aim of this study is to compare the geometrical accuracy and the fatigue lives predicted by finite element analysis (FEA) among three clasps manufactured with different building orientations. Besides, this paper proposed a calculation method of the moment of inertia of area and cross-sectional area along with the arm as the geometrical parameters. One of the clasps manufactured with a cylindrical chucking part for the fatigue test had almost the same geometrical parameters with the CAD design. Also, the authors' fatigue life prediction method using the CAD based FEA was verified through comparison with micro-CT image-based FEA. The other two clasps had larger geometrical parameters than the CAD design, resulting in longer fatigue lives. The results implied the importance of calculating the moment of inertia of the area in the design of the clasp arm.</p>","PeriodicalId":1,"journal":{"name":"Accounts of Chemical Research","volume":null,"pages":null},"PeriodicalIF":16.4000,"publicationDate":"2024-09-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Finite element analysis of fatigue life of commercially pure titanium clasps additively manufactured with different building orientations.\",\"authors\":\"Kento Odaka, Mikiya Sugano, Taichi Kawamoto, Naoki Takano, Satoru Matsunaga\",\"doi\":\"10.4012/dmj.2024-023\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The geometrical accuracy of additively manufactured pure titanium clasps depends on the building orientation. The aim of this study is to compare the geometrical accuracy and the fatigue lives predicted by finite element analysis (FEA) among three clasps manufactured with different building orientations. Besides, this paper proposed a calculation method of the moment of inertia of area and cross-sectional area along with the arm as the geometrical parameters. One of the clasps manufactured with a cylindrical chucking part for the fatigue test had almost the same geometrical parameters with the CAD design. Also, the authors' fatigue life prediction method using the CAD based FEA was verified through comparison with micro-CT image-based FEA. The other two clasps had larger geometrical parameters than the CAD design, resulting in longer fatigue lives. The results implied the importance of calculating the moment of inertia of the area in the design of the clasp arm.</p>\",\"PeriodicalId\":1,\"journal\":{\"name\":\"Accounts of Chemical Research\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":16.4000,\"publicationDate\":\"2024-09-28\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Accounts of Chemical Research\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.4012/dmj.2024-023\",\"RegionNum\":1,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/8/9 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q1\",\"JCRName\":\"CHEMISTRY, MULTIDISCIPLINARY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Accounts of Chemical Research","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.4012/dmj.2024-023","RegionNum":1,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/8/9 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"CHEMISTRY, MULTIDISCIPLINARY","Score":null,"Total":0}
Finite element analysis of fatigue life of commercially pure titanium clasps additively manufactured with different building orientations.
The geometrical accuracy of additively manufactured pure titanium clasps depends on the building orientation. The aim of this study is to compare the geometrical accuracy and the fatigue lives predicted by finite element analysis (FEA) among three clasps manufactured with different building orientations. Besides, this paper proposed a calculation method of the moment of inertia of area and cross-sectional area along with the arm as the geometrical parameters. One of the clasps manufactured with a cylindrical chucking part for the fatigue test had almost the same geometrical parameters with the CAD design. Also, the authors' fatigue life prediction method using the CAD based FEA was verified through comparison with micro-CT image-based FEA. The other two clasps had larger geometrical parameters than the CAD design, resulting in longer fatigue lives. The results implied the importance of calculating the moment of inertia of the area in the design of the clasp arm.
期刊介绍:
Accounts of Chemical Research presents short, concise and critical articles offering easy-to-read overviews of basic research and applications in all areas of chemistry and biochemistry. These short reviews focus on research from the author’s own laboratory and are designed to teach the reader about a research project. In addition, Accounts of Chemical Research publishes commentaries that give an informed opinion on a current research problem. Special Issues online are devoted to a single topic of unusual activity and significance.
Accounts of Chemical Research replaces the traditional article abstract with an article "Conspectus." These entries synopsize the research affording the reader a closer look at the content and significance of an article. Through this provision of a more detailed description of the article contents, the Conspectus enhances the article's discoverability by search engines and the exposure for the research.