制备和认证用于量热分析的苯甲酸标准物质

{"title":"制备和认证用于量热分析的苯甲酸标准物质","authors":"","doi":"10.1016/j.meaene.2024.100016","DOIUrl":null,"url":null,"abstract":"<div><p>Benzoic acid reference material is indispensable for bomb calorimeter instrument calibration and validation of gross calorific value (GCV) analysis of any substance. In this work, we demonstrated the preparation of benzoic acid reference material through a homogeneity study, round-robin analysis, and stability study. Two-factor analysis of variance (ANOVA) test for gross calorific value in the randomly selected sub-samples of benzoic acid exhibits a lower <em>F</em><sub><em>TS</em></sub> value than the <em>F</em><sub><em>crit</em></sub> value, indicating that the samples are sufficiently homogeneous. The calculated uncertainty of between-bottle (<em>u</em><sub><em>bb</em></sub>) and uncertainty of homogeneity (<em>u</em><sub><em>hom</em></sub>) for GCV of benzoic acid in the sub-samples were found as 1.82 and 4.42 ​cal/g respectively. We found that the observed homogeneity (<em>u</em><sub><em>hom (Finding)</em></sub>) value is lower than the assumed homogeneity (<em>u</em><sub><em>hom (Assume)</em></sub>) value for the prepared benzoic acid reference material. Overall observations confirm that the sub-samples are sufficiently homogeneous. Moreover, the round-robin analysis/or inter-laboratory comparison analysis was conducted to assign the gross calorific value and determine the characterization uncertainty. The seventh order of Grubbs' analysis was done using robust estimator Alogoritm A to assign the GCV of benzoic acid. Finally, the measurement uncertainty of the assigned GCV of benzoic acid was calculated with the combined uncertainties from various sources.</p></div>","PeriodicalId":100897,"journal":{"name":"Measurement: Energy","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2024-07-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.sciencedirect.com/science/article/pii/S2950345024000162/pdfft?md5=043b511c377475bdbd886ff5c0dda2c6&pid=1-s2.0-S2950345024000162-main.pdf","citationCount":"0","resultStr":"{\"title\":\"Preparation and certification of benzoic acid reference material for calorimetry analysis\",\"authors\":\"\",\"doi\":\"10.1016/j.meaene.2024.100016\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>Benzoic acid reference material is indispensable for bomb calorimeter instrument calibration and validation of gross calorific value (GCV) analysis of any substance. In this work, we demonstrated the preparation of benzoic acid reference material through a homogeneity study, round-robin analysis, and stability study. Two-factor analysis of variance (ANOVA) test for gross calorific value in the randomly selected sub-samples of benzoic acid exhibits a lower <em>F</em><sub><em>TS</em></sub> value than the <em>F</em><sub><em>crit</em></sub> value, indicating that the samples are sufficiently homogeneous. The calculated uncertainty of between-bottle (<em>u</em><sub><em>bb</em></sub>) and uncertainty of homogeneity (<em>u</em><sub><em>hom</em></sub>) for GCV of benzoic acid in the sub-samples were found as 1.82 and 4.42 ​cal/g respectively. We found that the observed homogeneity (<em>u</em><sub><em>hom (Finding)</em></sub>) value is lower than the assumed homogeneity (<em>u</em><sub><em>hom (Assume)</em></sub>) value for the prepared benzoic acid reference material. Overall observations confirm that the sub-samples are sufficiently homogeneous. Moreover, the round-robin analysis/or inter-laboratory comparison analysis was conducted to assign the gross calorific value and determine the characterization uncertainty. The seventh order of Grubbs' analysis was done using robust estimator Alogoritm A to assign the GCV of benzoic acid. Finally, the measurement uncertainty of the assigned GCV of benzoic acid was calculated with the combined uncertainties from various sources.</p></div>\",\"PeriodicalId\":100897,\"journal\":{\"name\":\"Measurement: Energy\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-07-31\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.sciencedirect.com/science/article/pii/S2950345024000162/pdfft?md5=043b511c377475bdbd886ff5c0dda2c6&pid=1-s2.0-S2950345024000162-main.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Measurement: Energy\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S2950345024000162\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Measurement: Energy","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2950345024000162","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

苯甲酸标准物质是炸弹量热仪校准和验证任何物质总热值(GCV)分析所不可或缺的。在这项工作中,我们通过均一性研究、循环分析和稳定性研究证明了苯甲酸标准物质的制备方法。在随机抽取的苯甲酸子样品中,总热值的双因素方差分析(ANOVA)检验显示 FTS 值低于 Fcrit 值,表明样品具有足够的均匀性。计算得出的苯甲酸子样品总热值的瓶间不确定度(ubb)和均质性不确定度(uhom)分别为 1.82 和 4.42 卡/克。我们发现观察到的均一性(uhom (Finding))值低于制备的苯甲酸标准物质的假定均一性(uhom (Assume))值。总体观察结果证实,子样品具有足够的均匀性。此外,还进行了循环分析/或实验室间比对分析,以确定总热值和表征不确定性。使用稳健估计器 Alogoritm A 进行格拉布斯七阶分析,以确定苯甲酸的总热值。最后,利用各种来源的综合不确定性,计算出分配的苯甲酸 GCV 的测量不确定性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Preparation and certification of benzoic acid reference material for calorimetry analysis

Benzoic acid reference material is indispensable for bomb calorimeter instrument calibration and validation of gross calorific value (GCV) analysis of any substance. In this work, we demonstrated the preparation of benzoic acid reference material through a homogeneity study, round-robin analysis, and stability study. Two-factor analysis of variance (ANOVA) test for gross calorific value in the randomly selected sub-samples of benzoic acid exhibits a lower FTS value than the Fcrit value, indicating that the samples are sufficiently homogeneous. The calculated uncertainty of between-bottle (ubb) and uncertainty of homogeneity (uhom) for GCV of benzoic acid in the sub-samples were found as 1.82 and 4.42 ​cal/g respectively. We found that the observed homogeneity (uhom (Finding)) value is lower than the assumed homogeneity (uhom (Assume)) value for the prepared benzoic acid reference material. Overall observations confirm that the sub-samples are sufficiently homogeneous. Moreover, the round-robin analysis/or inter-laboratory comparison analysis was conducted to assign the gross calorific value and determine the characterization uncertainty. The seventh order of Grubbs' analysis was done using robust estimator Alogoritm A to assign the GCV of benzoic acid. Finally, the measurement uncertainty of the assigned GCV of benzoic acid was calculated with the combined uncertainties from various sources.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信