{"title":"加强弱电网中锁相环的稳定性控制","authors":"","doi":"10.1016/j.ijepes.2024.110145","DOIUrl":null,"url":null,"abstract":"<div><p>This paper analyzes the factors affecting the stability of phase-locked loops (PLLs) in weak power grids. By establishing a PLL model in weak power grids, it is found that line impedance, grid frequency disturbances, and output power all have an impact on PLL stability. The influence of line impedance, grid frequency disturbances, and output power on PLL is analyzed using the phase plane method. Additionally, it is observed that increasing the PLL damping ratio can enhance PLL stability, but when the damping ratio exceeds the critical damping ratio, PLL instability may occur. Therefore, this paper divides the controllable range of PLL into two cases: damping ratio greater than the critical damping ratio and damping ratio less than the critical damping ratio. For the case where the damping ratio is less than the critical damping ratio, a transient virtual inductance control method is proposed to enhance the PLL damping ratio and improve PLL stability without introducing power coupling. For the case where the damping ratio is greater than the critical damping ratio, PLL adaptive parameter adjustment control is proposed to ensure that the PLL trajectory does not diverge by increasing the PLL adjustment time without increasing the damping ratio, thus improving VSC stability. Finally, a comparison with conventional methods is conducted, and the feasibility and correctness are analyzed through time-domain simulations, followed by presenting the result analysis.</p></div>","PeriodicalId":50326,"journal":{"name":"International Journal of Electrical Power & Energy Systems","volume":null,"pages":null},"PeriodicalIF":5.0000,"publicationDate":"2024-08-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.sciencedirect.com/science/article/pii/S0142061524003661/pdfft?md5=b28533d33093b5f92f1e964010b8865a&pid=1-s2.0-S0142061524003661-main.pdf","citationCount":"0","resultStr":"{\"title\":\"Enhancing stability control of Phase-Locked loop in weak power grids\",\"authors\":\"\",\"doi\":\"10.1016/j.ijepes.2024.110145\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>This paper analyzes the factors affecting the stability of phase-locked loops (PLLs) in weak power grids. By establishing a PLL model in weak power grids, it is found that line impedance, grid frequency disturbances, and output power all have an impact on PLL stability. The influence of line impedance, grid frequency disturbances, and output power on PLL is analyzed using the phase plane method. Additionally, it is observed that increasing the PLL damping ratio can enhance PLL stability, but when the damping ratio exceeds the critical damping ratio, PLL instability may occur. Therefore, this paper divides the controllable range of PLL into two cases: damping ratio greater than the critical damping ratio and damping ratio less than the critical damping ratio. For the case where the damping ratio is less than the critical damping ratio, a transient virtual inductance control method is proposed to enhance the PLL damping ratio and improve PLL stability without introducing power coupling. For the case where the damping ratio is greater than the critical damping ratio, PLL adaptive parameter adjustment control is proposed to ensure that the PLL trajectory does not diverge by increasing the PLL adjustment time without increasing the damping ratio, thus improving VSC stability. Finally, a comparison with conventional methods is conducted, and the feasibility and correctness are analyzed through time-domain simulations, followed by presenting the result analysis.</p></div>\",\"PeriodicalId\":50326,\"journal\":{\"name\":\"International Journal of Electrical Power & Energy Systems\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":5.0000,\"publicationDate\":\"2024-08-03\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.sciencedirect.com/science/article/pii/S0142061524003661/pdfft?md5=b28533d33093b5f92f1e964010b8865a&pid=1-s2.0-S0142061524003661-main.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Journal of Electrical Power & Energy Systems\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S0142061524003661\",\"RegionNum\":2,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"ENGINEERING, ELECTRICAL & ELECTRONIC\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Electrical Power & Energy Systems","FirstCategoryId":"5","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0142061524003661","RegionNum":2,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
Enhancing stability control of Phase-Locked loop in weak power grids
This paper analyzes the factors affecting the stability of phase-locked loops (PLLs) in weak power grids. By establishing a PLL model in weak power grids, it is found that line impedance, grid frequency disturbances, and output power all have an impact on PLL stability. The influence of line impedance, grid frequency disturbances, and output power on PLL is analyzed using the phase plane method. Additionally, it is observed that increasing the PLL damping ratio can enhance PLL stability, but when the damping ratio exceeds the critical damping ratio, PLL instability may occur. Therefore, this paper divides the controllable range of PLL into two cases: damping ratio greater than the critical damping ratio and damping ratio less than the critical damping ratio. For the case where the damping ratio is less than the critical damping ratio, a transient virtual inductance control method is proposed to enhance the PLL damping ratio and improve PLL stability without introducing power coupling. For the case where the damping ratio is greater than the critical damping ratio, PLL adaptive parameter adjustment control is proposed to ensure that the PLL trajectory does not diverge by increasing the PLL adjustment time without increasing the damping ratio, thus improving VSC stability. Finally, a comparison with conventional methods is conducted, and the feasibility and correctness are analyzed through time-domain simulations, followed by presenting the result analysis.
期刊介绍:
The journal covers theoretical developments in electrical power and energy systems and their applications. The coverage embraces: generation and network planning; reliability; long and short term operation; expert systems; neural networks; object oriented systems; system control centres; database and information systems; stock and parameter estimation; system security and adequacy; network theory, modelling and computation; small and large system dynamics; dynamic model identification; on-line control including load and switching control; protection; distribution systems; energy economics; impact of non-conventional systems; and man-machine interfaces.
As well as original research papers, the journal publishes short contributions, book reviews and conference reports. All papers are peer-reviewed by at least two referees.