柔性手术机器人抓取力反馈机制的设计与研究

IF 2.3 3区 医学 Q2 SURGERY
Fuhao Wang, Ye Wang, Qiqi Pan, Jingjing Luo, Hongbo Wang, Xiaoyang Kang, Xueze Zhang
{"title":"柔性手术机器人抓取力反馈机制的设计与研究","authors":"Fuhao Wang,&nbsp;Ye Wang,&nbsp;Qiqi Pan,&nbsp;Jingjing Luo,&nbsp;Hongbo Wang,&nbsp;Xiaoyang Kang,&nbsp;Xueze Zhang","doi":"10.1002/rcs.2667","DOIUrl":null,"url":null,"abstract":"<div>\n \n \n <section>\n \n <h3> Background</h3>\n \n <p>Robot-assisted microsurgery (RAMS) is gradually becoming the preferred method for some delicate surgical procedures. However, the lack of haptic feedback reduces the safety of the surgery. Surgeons are unable to feel the grasping force between surgical instruments and the patient's tissues, which can easily lead to grasping failure or tissue damage.</p>\n </section>\n \n <section>\n \n <h3> Methods</h3>\n \n <p>This paper proposes a tendon-driven grasping force feedback mechanism, consisting of a follower hand and a leader hand, to address the lack of grasping force feedback in flexible surgical robots. Considering the friction in the tendon transmission process, a grasping force estimation model is established for the follower hand. The admittance control model is designed for force/position control of the leader hand.</p>\n </section>\n \n <section>\n \n <h3> Results</h3>\n \n <p>Through experimental validation, it has been confirmed that the grasping force sensing range of the follower hand is 0.5–5 N, with a sensing accuracy of 0.3 N. The leader hand is capable of providing feedback forces in the range of 0–5 N, with a static force accuracy of 0.1 N.</p>\n </section>\n \n <section>\n \n <h3> Conclusions</h3>\n \n <p>The designed mechanism and control strategy can provide the grasping force feedback function. Future work will focus on improving force feedback performance.</p>\n </section>\n \n <section>\n \n <h3> Trial Registration</h3>\n \n <p>This research has no clinical trials.</p>\n </section>\n </div>","PeriodicalId":50311,"journal":{"name":"International Journal of Medical Robotics and Computer Assisted Surgery","volume":null,"pages":null},"PeriodicalIF":2.3000,"publicationDate":"2024-08-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Design and Research of the Grasping Force Feedback Mechanism of Flexible Surgical Robots\",\"authors\":\"Fuhao Wang,&nbsp;Ye Wang,&nbsp;Qiqi Pan,&nbsp;Jingjing Luo,&nbsp;Hongbo Wang,&nbsp;Xiaoyang Kang,&nbsp;Xueze Zhang\",\"doi\":\"10.1002/rcs.2667\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div>\\n \\n \\n <section>\\n \\n <h3> Background</h3>\\n \\n <p>Robot-assisted microsurgery (RAMS) is gradually becoming the preferred method for some delicate surgical procedures. However, the lack of haptic feedback reduces the safety of the surgery. Surgeons are unable to feel the grasping force between surgical instruments and the patient's tissues, which can easily lead to grasping failure or tissue damage.</p>\\n </section>\\n \\n <section>\\n \\n <h3> Methods</h3>\\n \\n <p>This paper proposes a tendon-driven grasping force feedback mechanism, consisting of a follower hand and a leader hand, to address the lack of grasping force feedback in flexible surgical robots. Considering the friction in the tendon transmission process, a grasping force estimation model is established for the follower hand. The admittance control model is designed for force/position control of the leader hand.</p>\\n </section>\\n \\n <section>\\n \\n <h3> Results</h3>\\n \\n <p>Through experimental validation, it has been confirmed that the grasping force sensing range of the follower hand is 0.5–5 N, with a sensing accuracy of 0.3 N. The leader hand is capable of providing feedback forces in the range of 0–5 N, with a static force accuracy of 0.1 N.</p>\\n </section>\\n \\n <section>\\n \\n <h3> Conclusions</h3>\\n \\n <p>The designed mechanism and control strategy can provide the grasping force feedback function. Future work will focus on improving force feedback performance.</p>\\n </section>\\n \\n <section>\\n \\n <h3> Trial Registration</h3>\\n \\n <p>This research has no clinical trials.</p>\\n </section>\\n </div>\",\"PeriodicalId\":50311,\"journal\":{\"name\":\"International Journal of Medical Robotics and Computer Assisted Surgery\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":2.3000,\"publicationDate\":\"2024-08-09\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Journal of Medical Robotics and Computer Assisted Surgery\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://onlinelibrary.wiley.com/doi/10.1002/rcs.2667\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"SURGERY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Medical Robotics and Computer Assisted Surgery","FirstCategoryId":"3","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/rcs.2667","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"SURGERY","Score":null,"Total":0}
引用次数: 0

摘要

背景:机器人辅助显微外科手术(RAMS)逐渐成为一些精细外科手术的首选方法。然而,触觉反馈的缺乏降低了手术的安全性。外科医生无法感受到手术器械与患者组织之间的抓取力,这很容易导致抓取失败或组织损伤:本文针对柔性手术机器人缺乏抓取力反馈的问题,提出了一种由跟随手和领导手组成的肌腱驱动抓取力反馈机制。考虑到肌腱传输过程中的摩擦,建立了从动手抓取力估计模型。结果:通过实验验证,确认从动手的抓取力感应范围为 0.5-5 N,感应精度为 0.3 N:结论:所设计的机构和控制策略能够提供抓取力反馈功能。今后的工作重点是提高力反馈性能:本研究没有临床试验。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Design and Research of the Grasping Force Feedback Mechanism of Flexible Surgical Robots

Background

Robot-assisted microsurgery (RAMS) is gradually becoming the preferred method for some delicate surgical procedures. However, the lack of haptic feedback reduces the safety of the surgery. Surgeons are unable to feel the grasping force between surgical instruments and the patient's tissues, which can easily lead to grasping failure or tissue damage.

Methods

This paper proposes a tendon-driven grasping force feedback mechanism, consisting of a follower hand and a leader hand, to address the lack of grasping force feedback in flexible surgical robots. Considering the friction in the tendon transmission process, a grasping force estimation model is established for the follower hand. The admittance control model is designed for force/position control of the leader hand.

Results

Through experimental validation, it has been confirmed that the grasping force sensing range of the follower hand is 0.5–5 N, with a sensing accuracy of 0.3 N. The leader hand is capable of providing feedback forces in the range of 0–5 N, with a static force accuracy of 0.1 N.

Conclusions

The designed mechanism and control strategy can provide the grasping force feedback function. Future work will focus on improving force feedback performance.

Trial Registration

This research has no clinical trials.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
4.50
自引率
12.00%
发文量
131
审稿时长
6-12 weeks
期刊介绍: The International Journal of Medical Robotics and Computer Assisted Surgery provides a cross-disciplinary platform for presenting the latest developments in robotics and computer assisted technologies for medical applications. The journal publishes cutting-edge papers and expert reviews, complemented by commentaries, correspondence and conference highlights that stimulate discussion and exchange of ideas. Areas of interest include robotic surgery aids and systems, operative planning tools, medical imaging and visualisation, simulation and navigation, virtual reality, intuitive command and control systems, haptics and sensor technologies. In addition to research and surgical planning studies, the journal welcomes papers detailing clinical trials and applications of computer-assisted workflows and robotic systems in neurosurgery, urology, paediatric, orthopaedic, craniofacial, cardiovascular, thoraco-abdominal, musculoskeletal and visceral surgery. Articles providing critical analysis of clinical trials, assessment of the benefits and risks of the application of these technologies, commenting on ease of use, or addressing surgical education and training issues are also encouraged. The journal aims to foster a community that encompasses medical practitioners, researchers, and engineers and computer scientists developing robotic systems and computational tools in academic and commercial environments, with the intention of promoting and developing these exciting areas of medical technology.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信