巩膜固定 Carlevale 眼内透镜后的屈光效果。

IF 2.9 3区 医学 Q1 OPHTHALMOLOGY
Nathan Courat, Frédéric Gobert, Thibault Naudin, Alexandre Ducloux, Camille Alleyrat, Nicolas Leveziel
{"title":"巩膜固定 Carlevale 眼内透镜后的屈光效果。","authors":"Nathan Courat, Frédéric Gobert, Thibault Naudin, Alexandre Ducloux, Camille Alleyrat, Nicolas Leveziel","doi":"10.3928/1081597X-20240611-04","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To assess the refractive predictability of the Carlevale sutureless scleral fixation intraocular lens (IOL) (Sole-ko IOL Division) power calculation.</p><p><strong>Methods: </strong>This retrospective, non-comparative, interventional case series included patients without a capsular support having undergone sutureless scleral fixation IOL implantation in two French hospitals between October 2019 and April 2022. IOL calculation was performed with the Barrett Universal II, Hoffer Q, Holladay 1, and SRK/T formulas with constant optimization to achieve a mean arithmetic prediction error equal to zero. The main outcomes were prediction error (PE) and its standard deviation (SD-PE), the median absolute error (MedAE), the mean absolute error (MAE), and the percentage of eyes with PE within ±0.50, ±1.00 and ±2.00 diopters (D) 6 months after surgery.</p><p><strong>Results: </strong>Thirty eyes of 30 patients were included in the study. The mean age was 66.6 years, the mean axial length was 24.31 mm, and the mean keratometry was 43.07 D. SDPE ranged from 0.73 to 0.87 D depending on the formula. MedAE ranged from 0.38 to 0.61 D, and MAE from 0.52 to 0.68 D. Between 46.7% and 56.7% of eyes were within ±0.50 D, 76.7% and 90.0% were within ±1.00 D, and 96.7% were within ±2.00 D of target equivalent. No statistically significant difference was observed between the four formulas for any outcomes.</p><p><strong>Conclusions: </strong>This study confirmed that the design of the Carlevale sutureless scleral fixation IOL provides satisfactory refractive results. <b>[<i>J Refract Surg</i>. 2024;40(8):e527-e532.]</b>.</p>","PeriodicalId":16951,"journal":{"name":"Journal of refractive surgery","volume":"40 8","pages":"e527-e532"},"PeriodicalIF":2.9000,"publicationDate":"2024-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Refractive Outcomes After Scleral Fixation of the Carlevale Intraocular Lens.\",\"authors\":\"Nathan Courat, Frédéric Gobert, Thibault Naudin, Alexandre Ducloux, Camille Alleyrat, Nicolas Leveziel\",\"doi\":\"10.3928/1081597X-20240611-04\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>To assess the refractive predictability of the Carlevale sutureless scleral fixation intraocular lens (IOL) (Sole-ko IOL Division) power calculation.</p><p><strong>Methods: </strong>This retrospective, non-comparative, interventional case series included patients without a capsular support having undergone sutureless scleral fixation IOL implantation in two French hospitals between October 2019 and April 2022. IOL calculation was performed with the Barrett Universal II, Hoffer Q, Holladay 1, and SRK/T formulas with constant optimization to achieve a mean arithmetic prediction error equal to zero. The main outcomes were prediction error (PE) and its standard deviation (SD-PE), the median absolute error (MedAE), the mean absolute error (MAE), and the percentage of eyes with PE within ±0.50, ±1.00 and ±2.00 diopters (D) 6 months after surgery.</p><p><strong>Results: </strong>Thirty eyes of 30 patients were included in the study. The mean age was 66.6 years, the mean axial length was 24.31 mm, and the mean keratometry was 43.07 D. SDPE ranged from 0.73 to 0.87 D depending on the formula. MedAE ranged from 0.38 to 0.61 D, and MAE from 0.52 to 0.68 D. Between 46.7% and 56.7% of eyes were within ±0.50 D, 76.7% and 90.0% were within ±1.00 D, and 96.7% were within ±2.00 D of target equivalent. No statistically significant difference was observed between the four formulas for any outcomes.</p><p><strong>Conclusions: </strong>This study confirmed that the design of the Carlevale sutureless scleral fixation IOL provides satisfactory refractive results. <b>[<i>J Refract Surg</i>. 2024;40(8):e527-e532.]</b>.</p>\",\"PeriodicalId\":16951,\"journal\":{\"name\":\"Journal of refractive surgery\",\"volume\":\"40 8\",\"pages\":\"e527-e532\"},\"PeriodicalIF\":2.9000,\"publicationDate\":\"2024-08-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of refractive surgery\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.3928/1081597X-20240611-04\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"OPHTHALMOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of refractive surgery","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.3928/1081597X-20240611-04","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

目的:评估Carlevale无缝线巩膜固定人工晶体(IOL)(Sole-ko IOL Division)功率计算的屈光预测性:该回顾性、非比较性、介入性病例系列包括2019年10月至2022年4月期间在两家法国医院接受无缝线巩膜固定人工晶体植入术的无囊支持患者。人工晶体计算采用 Barrett Universal II、Hoffer Q、Holladay 1 和 SRK/T 公式,并不断进行优化,以实现平均算术预测误差等于零。主要结果是预测误差(PE)及其标准差(SD-PE)、绝对误差中位数(MedAE)、平均绝对误差(MAE)以及术后 6 个月后 PE 在±0.50、±1.00 和 ±2.00 屈光度(D)以内的眼睛的百分比:研究共纳入了 30 名患者的 30 只眼睛。平均年龄为 66.6 岁,平均轴长为 24.31 mm,平均角膜度数为 43.07 D。46.7%到56.7%的眼睛在±0.50 D以内,76.7%到90.0%的眼睛在±1.00 D以内,96.7%的眼睛在±2.00 D以内。在任何结果上,四种公式之间都没有统计学意义上的差异:本研究证实,Carlevale 无缝线巩膜固定人工晶体的设计可提供令人满意的屈光效果。[J Refract Surg. 2024;40(8):e527-e532.]。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Refractive Outcomes After Scleral Fixation of the Carlevale Intraocular Lens.

Purpose: To assess the refractive predictability of the Carlevale sutureless scleral fixation intraocular lens (IOL) (Sole-ko IOL Division) power calculation.

Methods: This retrospective, non-comparative, interventional case series included patients without a capsular support having undergone sutureless scleral fixation IOL implantation in two French hospitals between October 2019 and April 2022. IOL calculation was performed with the Barrett Universal II, Hoffer Q, Holladay 1, and SRK/T formulas with constant optimization to achieve a mean arithmetic prediction error equal to zero. The main outcomes were prediction error (PE) and its standard deviation (SD-PE), the median absolute error (MedAE), the mean absolute error (MAE), and the percentage of eyes with PE within ±0.50, ±1.00 and ±2.00 diopters (D) 6 months after surgery.

Results: Thirty eyes of 30 patients were included in the study. The mean age was 66.6 years, the mean axial length was 24.31 mm, and the mean keratometry was 43.07 D. SDPE ranged from 0.73 to 0.87 D depending on the formula. MedAE ranged from 0.38 to 0.61 D, and MAE from 0.52 to 0.68 D. Between 46.7% and 56.7% of eyes were within ±0.50 D, 76.7% and 90.0% were within ±1.00 D, and 96.7% were within ±2.00 D of target equivalent. No statistically significant difference was observed between the four formulas for any outcomes.

Conclusions: This study confirmed that the design of the Carlevale sutureless scleral fixation IOL provides satisfactory refractive results. [J Refract Surg. 2024;40(8):e527-e532.].

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
5.10
自引率
12.50%
发文量
160
审稿时长
4-8 weeks
期刊介绍: The Journal of Refractive Surgery, the official journal of the International Society of Refractive Surgery, a partner of the American Academy of Ophthalmology, has been a monthly peer-reviewed forum for original research, review, and evaluation of refractive and lens-based surgical procedures for more than 30 years. Practical, clinically valuable articles provide readers with the most up-to-date information regarding advances in the field of refractive surgery. Begin to explore the Journal and all of its great benefits such as: • Columns including “Translational Science,” “Surgical Techniques,” and “Biomechanics” • Supplemental videos and materials available for many articles • Access to current articles, as well as several years of archived content • Articles posted online just 2 months after acceptance.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信