{"title":"在治疗非创伤性股骨头坏死时,氧化铝双极半关节置换术与金属双极半关节置换术的比较问题。","authors":"Seneki Kobayashi, Nobuhiko Sugano, Wataru Ando, Wakaba Fukushima, Kyoko Kondo, Takashi Sakai","doi":"10.1007/s00264-024-06258-6","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>A nationwide multicenter follow-up cohort study of hip replacement arthroplasties performed for nontraumatic osteonecrosis of the femoral head (ONFH) aimed to answer the following questions: What factors were associated with need for reoperation? Although many modifications were made in bipolar hemiarthroplasties (BPs) to improve their durability, could we find any evidence of their efficacy?</p><p><strong>Methods: </strong>Excluding 58 infected hips and 43 ABS THAs with very poor survivorship, we analyzed 7393 arthroplasties; 6284 total hip arthroplasties (THAs), 886 BPs, 188 total resurfacing arthroplasties, and 35 hemi-resurfacing arthroplasties (hRSs). In the 886 BPs, 440 hips had a smooth small-diameter prosthetic neck (nBPs), 667 hips had a smooth neck (sBPs), 116 hips had highly cross-linked polyethylene in the outer head (hBPs), and 238 hips had an outer head whose outer surface was alumina ceramic (aBPs) (648 hips had an outer head whose outer surface was metal [mBPs]). Multivariate analyses using a Cox proportional-hazard model analyzed risk factors.</p><p><strong>Results: </strong>Follow-up ranged from 0.1 to 27 (average, 6.9) years, during which 265 hips (3.6%) needed reoperation. Combined systemic steroid use and excessive alcohol consumption and lateral approach were associated with higher risks, aBPs were less durable than THAs or mBPs, and hRSs were inferior to the others. Regarding BPs, the following divisions did not influence their survivorship; nBP or not, sBP or not, and hBP or not.</p><p><strong>Conclusions: </strong>Factors associated with reoperation risk were identified as described above. The modifications made in BPs did not improve their durability, but aBPs made it worse.</p><p><strong>Level of clinical evidence: </strong>Level III, therapeutic cohort study.</p>","PeriodicalId":14450,"journal":{"name":"International Orthopaedics","volume":" ","pages":"2535-2543"},"PeriodicalIF":2.0000,"publicationDate":"2024-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Concerns with alumina bipolar hemiarthroplasties compared to metal bipolar hemiarthroplasties when performed for nontraumatic osteonecrosis of the femoral head.\",\"authors\":\"Seneki Kobayashi, Nobuhiko Sugano, Wataru Ando, Wakaba Fukushima, Kyoko Kondo, Takashi Sakai\",\"doi\":\"10.1007/s00264-024-06258-6\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>A nationwide multicenter follow-up cohort study of hip replacement arthroplasties performed for nontraumatic osteonecrosis of the femoral head (ONFH) aimed to answer the following questions: What factors were associated with need for reoperation? Although many modifications were made in bipolar hemiarthroplasties (BPs) to improve their durability, could we find any evidence of their efficacy?</p><p><strong>Methods: </strong>Excluding 58 infected hips and 43 ABS THAs with very poor survivorship, we analyzed 7393 arthroplasties; 6284 total hip arthroplasties (THAs), 886 BPs, 188 total resurfacing arthroplasties, and 35 hemi-resurfacing arthroplasties (hRSs). In the 886 BPs, 440 hips had a smooth small-diameter prosthetic neck (nBPs), 667 hips had a smooth neck (sBPs), 116 hips had highly cross-linked polyethylene in the outer head (hBPs), and 238 hips had an outer head whose outer surface was alumina ceramic (aBPs) (648 hips had an outer head whose outer surface was metal [mBPs]). Multivariate analyses using a Cox proportional-hazard model analyzed risk factors.</p><p><strong>Results: </strong>Follow-up ranged from 0.1 to 27 (average, 6.9) years, during which 265 hips (3.6%) needed reoperation. Combined systemic steroid use and excessive alcohol consumption and lateral approach were associated with higher risks, aBPs were less durable than THAs or mBPs, and hRSs were inferior to the others. Regarding BPs, the following divisions did not influence their survivorship; nBP or not, sBP or not, and hBP or not.</p><p><strong>Conclusions: </strong>Factors associated with reoperation risk were identified as described above. The modifications made in BPs did not improve their durability, but aBPs made it worse.</p><p><strong>Level of clinical evidence: </strong>Level III, therapeutic cohort study.</p>\",\"PeriodicalId\":14450,\"journal\":{\"name\":\"International Orthopaedics\",\"volume\":\" \",\"pages\":\"2535-2543\"},\"PeriodicalIF\":2.0000,\"publicationDate\":\"2024-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Orthopaedics\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1007/s00264-024-06258-6\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/8/8 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q2\",\"JCRName\":\"ORTHOPEDICS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Orthopaedics","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s00264-024-06258-6","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/8/8 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
Concerns with alumina bipolar hemiarthroplasties compared to metal bipolar hemiarthroplasties when performed for nontraumatic osteonecrosis of the femoral head.
Purpose: A nationwide multicenter follow-up cohort study of hip replacement arthroplasties performed for nontraumatic osteonecrosis of the femoral head (ONFH) aimed to answer the following questions: What factors were associated with need for reoperation? Although many modifications were made in bipolar hemiarthroplasties (BPs) to improve their durability, could we find any evidence of their efficacy?
Methods: Excluding 58 infected hips and 43 ABS THAs with very poor survivorship, we analyzed 7393 arthroplasties; 6284 total hip arthroplasties (THAs), 886 BPs, 188 total resurfacing arthroplasties, and 35 hemi-resurfacing arthroplasties (hRSs). In the 886 BPs, 440 hips had a smooth small-diameter prosthetic neck (nBPs), 667 hips had a smooth neck (sBPs), 116 hips had highly cross-linked polyethylene in the outer head (hBPs), and 238 hips had an outer head whose outer surface was alumina ceramic (aBPs) (648 hips had an outer head whose outer surface was metal [mBPs]). Multivariate analyses using a Cox proportional-hazard model analyzed risk factors.
Results: Follow-up ranged from 0.1 to 27 (average, 6.9) years, during which 265 hips (3.6%) needed reoperation. Combined systemic steroid use and excessive alcohol consumption and lateral approach were associated with higher risks, aBPs were less durable than THAs or mBPs, and hRSs were inferior to the others. Regarding BPs, the following divisions did not influence their survivorship; nBP or not, sBP or not, and hBP or not.
Conclusions: Factors associated with reoperation risk were identified as described above. The modifications made in BPs did not improve their durability, but aBPs made it worse.
Level of clinical evidence: Level III, therapeutic cohort study.
期刊介绍:
International Orthopaedics, the Official Journal of the Société Internationale de Chirurgie Orthopédique et de Traumatologie (SICOT) , publishes original papers from all over the world. The articles deal with clinical orthopaedic surgery or basic research directly connected with orthopaedic surgery. International Orthopaedics will also link all the members of SICOT by means of an insert that will be concerned with SICOT matters.
Finally, it is expected that news and information regarding all aspects of orthopaedic surgery, including meetings, panels, instructional courses, etc. will be brought to the attention of the readers.
Manuscripts submitted for publication must contain a statement to the effect that all human studies have been approved by the appropriate ethics committee and have therefore been performed in accordance with the ethical standards laid down in the 1964 Declaration of Helsinki. It should also be stated clearly in the text that all persons gave their informed consent prior to their inclusion in the study. Details that might disclose the identity of the subjects under study should be omitted.
Reports of animal experiments must state that the "Principles of laboratory animal care" (NIH publication No. 85-23, revised 1985) were followed, as well as specific national laws (e.g. the current version of the German Law on the Protection of Animals) where applicable.
The editors reserve the right to reject manuscripts that do not comply with the above-mentioned requirements. The author will be held responsible for false statements or for failure to fulfil the above-mentioned requirements.