在治疗非创伤性股骨头坏死时,氧化铝双极半关节置换术与金属双极半关节置换术的比较问题。

IF 4.6 Q2 MATERIALS SCIENCE, BIOMATERIALS
ACS Applied Bio Materials Pub Date : 2024-10-01 Epub Date: 2024-08-08 DOI:10.1007/s00264-024-06258-6
Seneki Kobayashi, Nobuhiko Sugano, Wataru Ando, Wakaba Fukushima, Kyoko Kondo, Takashi Sakai
{"title":"在治疗非创伤性股骨头坏死时,氧化铝双极半关节置换术与金属双极半关节置换术的比较问题。","authors":"Seneki Kobayashi, Nobuhiko Sugano, Wataru Ando, Wakaba Fukushima, Kyoko Kondo, Takashi Sakai","doi":"10.1007/s00264-024-06258-6","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>A nationwide multicenter follow-up cohort study of hip replacement arthroplasties performed for nontraumatic osteonecrosis of the femoral head (ONFH) aimed to answer the following questions: What factors were associated with need for reoperation? Although many modifications were made in bipolar hemiarthroplasties (BPs) to improve their durability, could we find any evidence of their efficacy?</p><p><strong>Methods: </strong>Excluding 58 infected hips and 43 ABS THAs with very poor survivorship, we analyzed 7393 arthroplasties; 6284 total hip arthroplasties (THAs), 886 BPs, 188 total resurfacing arthroplasties, and 35 hemi-resurfacing arthroplasties (hRSs). In the 886 BPs, 440 hips had a smooth small-diameter prosthetic neck (nBPs), 667 hips had a smooth neck (sBPs), 116 hips had highly cross-linked polyethylene in the outer head (hBPs), and 238 hips had an outer head whose outer surface was alumina ceramic (aBPs) (648 hips had an outer head whose outer surface was metal [mBPs]). Multivariate analyses using a Cox proportional-hazard model analyzed risk factors.</p><p><strong>Results: </strong>Follow-up ranged from 0.1 to 27 (average, 6.9) years, during which 265 hips (3.6%) needed reoperation. Combined systemic steroid use and excessive alcohol consumption and lateral approach were associated with higher risks, aBPs were less durable than THAs or mBPs, and hRSs were inferior to the others. Regarding BPs, the following divisions did not influence their survivorship; nBP or not, sBP or not, and hBP or not.</p><p><strong>Conclusions: </strong>Factors associated with reoperation risk were identified as described above. The modifications made in BPs did not improve their durability, but aBPs made it worse.</p><p><strong>Level of clinical evidence: </strong>Level III, therapeutic cohort study.</p>","PeriodicalId":2,"journal":{"name":"ACS Applied Bio Materials","volume":null,"pages":null},"PeriodicalIF":4.6000,"publicationDate":"2024-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Concerns with alumina bipolar hemiarthroplasties compared to metal bipolar hemiarthroplasties when performed for nontraumatic osteonecrosis of the femoral head.\",\"authors\":\"Seneki Kobayashi, Nobuhiko Sugano, Wataru Ando, Wakaba Fukushima, Kyoko Kondo, Takashi Sakai\",\"doi\":\"10.1007/s00264-024-06258-6\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>A nationwide multicenter follow-up cohort study of hip replacement arthroplasties performed for nontraumatic osteonecrosis of the femoral head (ONFH) aimed to answer the following questions: What factors were associated with need for reoperation? Although many modifications were made in bipolar hemiarthroplasties (BPs) to improve their durability, could we find any evidence of their efficacy?</p><p><strong>Methods: </strong>Excluding 58 infected hips and 43 ABS THAs with very poor survivorship, we analyzed 7393 arthroplasties; 6284 total hip arthroplasties (THAs), 886 BPs, 188 total resurfacing arthroplasties, and 35 hemi-resurfacing arthroplasties (hRSs). In the 886 BPs, 440 hips had a smooth small-diameter prosthetic neck (nBPs), 667 hips had a smooth neck (sBPs), 116 hips had highly cross-linked polyethylene in the outer head (hBPs), and 238 hips had an outer head whose outer surface was alumina ceramic (aBPs) (648 hips had an outer head whose outer surface was metal [mBPs]). Multivariate analyses using a Cox proportional-hazard model analyzed risk factors.</p><p><strong>Results: </strong>Follow-up ranged from 0.1 to 27 (average, 6.9) years, during which 265 hips (3.6%) needed reoperation. Combined systemic steroid use and excessive alcohol consumption and lateral approach were associated with higher risks, aBPs were less durable than THAs or mBPs, and hRSs were inferior to the others. Regarding BPs, the following divisions did not influence their survivorship; nBP or not, sBP or not, and hBP or not.</p><p><strong>Conclusions: </strong>Factors associated with reoperation risk were identified as described above. The modifications made in BPs did not improve their durability, but aBPs made it worse.</p><p><strong>Level of clinical evidence: </strong>Level III, therapeutic cohort study.</p>\",\"PeriodicalId\":2,\"journal\":{\"name\":\"ACS Applied Bio Materials\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":4.6000,\"publicationDate\":\"2024-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"ACS Applied Bio Materials\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1007/s00264-024-06258-6\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/8/8 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q2\",\"JCRName\":\"MATERIALS SCIENCE, BIOMATERIALS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"ACS Applied Bio Materials","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s00264-024-06258-6","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/8/8 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"MATERIALS SCIENCE, BIOMATERIALS","Score":null,"Total":0}
引用次数: 0

摘要

目的:一项针对非创伤性股骨头坏死(ONFH)髋关节置换术的全国性多中心随访队列研究旨在回答以下问题:需要再次手术的相关因素有哪些?尽管双极半关节置换术(BPs)为提高其耐久性进行了许多改良,但我们能否找到其疗效的证据?除去58例感染髋关节和43例存活率极低的ABS THAs,我们对7393例关节置换术进行了分析;其中包括6284例全髋关节置换术(THA)、886例BP、188例全人工关节置换术和35例半人工关节置换术(hRS)。在 886 例 BP 中,440 例髋关节的假体颈为光滑的小直径假体颈(nBPs),667 例髋关节的假体颈为光滑的假体颈(sBPs),116 例髋关节的外侧头为高度交联聚乙烯(hBPs),238 例髋关节的外侧头的外表面为氧化铝陶瓷(aBPs)(648 例髋关节的外侧头的外表面为金属[mBPs])。使用Cox比例危险模型进行多变量分析,分析风险因素:随访时间从0.1年到27年(平均6.9年)不等,期间有265个髋关节(3.6%)需要再次手术。合并使用全身类固醇、过度饮酒和侧方入路与较高的风险相关,aBPs的耐久性低于THAs或mBPs,而hRSs不如其他手术。至于BPs,以下划分并不影响其存活率:nBP与否、sBP与否和hBP与否:结论:如上所述,与再手术风险相关的因素已经确定。临床证据级别:临床证据级别:三级,治疗队列研究。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

Concerns with alumina bipolar hemiarthroplasties compared to metal bipolar hemiarthroplasties when performed for nontraumatic osteonecrosis of the femoral head.

Concerns with alumina bipolar hemiarthroplasties compared to metal bipolar hemiarthroplasties when performed for nontraumatic osteonecrosis of the femoral head.

Purpose: A nationwide multicenter follow-up cohort study of hip replacement arthroplasties performed for nontraumatic osteonecrosis of the femoral head (ONFH) aimed to answer the following questions: What factors were associated with need for reoperation? Although many modifications were made in bipolar hemiarthroplasties (BPs) to improve their durability, could we find any evidence of their efficacy?

Methods: Excluding 58 infected hips and 43 ABS THAs with very poor survivorship, we analyzed 7393 arthroplasties; 6284 total hip arthroplasties (THAs), 886 BPs, 188 total resurfacing arthroplasties, and 35 hemi-resurfacing arthroplasties (hRSs). In the 886 BPs, 440 hips had a smooth small-diameter prosthetic neck (nBPs), 667 hips had a smooth neck (sBPs), 116 hips had highly cross-linked polyethylene in the outer head (hBPs), and 238 hips had an outer head whose outer surface was alumina ceramic (aBPs) (648 hips had an outer head whose outer surface was metal [mBPs]). Multivariate analyses using a Cox proportional-hazard model analyzed risk factors.

Results: Follow-up ranged from 0.1 to 27 (average, 6.9) years, during which 265 hips (3.6%) needed reoperation. Combined systemic steroid use and excessive alcohol consumption and lateral approach were associated with higher risks, aBPs were less durable than THAs or mBPs, and hRSs were inferior to the others. Regarding BPs, the following divisions did not influence their survivorship; nBP or not, sBP or not, and hBP or not.

Conclusions: Factors associated with reoperation risk were identified as described above. The modifications made in BPs did not improve their durability, but aBPs made it worse.

Level of clinical evidence: Level III, therapeutic cohort study.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
ACS Applied Bio Materials
ACS Applied Bio Materials Chemistry-Chemistry (all)
CiteScore
9.40
自引率
2.10%
发文量
464
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信