全髋关节置换术后超声引导下髂腰肌腱注射的准确性:一项回顾性观察研究。

IF 1.3 Q3 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
Matthew W Kaufman, Chantal Nguyen, Yue Meng, Eugene Roh
{"title":"全髋关节置换术后超声引导下髂腰肌腱注射的准确性:一项回顾性观察研究。","authors":"Matthew W Kaufman, Chantal Nguyen, Yue Meng, Eugene Roh","doi":"10.1007/s40477-024-00904-w","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To describe and characterize the accuracy and benefit of a technique for performing ultrasound-guided needle placement for iliopsoas peritendon or bursa injections as an alternative method to fluoroscopic guidance.</p><p><strong>Materials and methods: </strong>Patients with a history of total hip arthroplasty who were referred by their orthopedic surgeon for iliopsoas peritendon or bursa corticosteroid injection for iliopsoas impingement syndrome between June 2017 and December 2019 were eligible for inclusion. Of these patients, 19 received a total of 26 ultrasound-guided needle placement followed by confirmatory fluoroscopic guidance prior to injection. Pre-injection and post-injection VAS scores were collected to monitor pain. Additionally, the patients were followed for 6 months via chart review after their injection to assess for complications, need for repeat injections, and progression to surgical intervention. The accuracy of a longitudinal in-plane distal to proximal approach to ultrasound guided needle placement was then evaluated.</p><p><strong>Results: </strong>Ultrasound guided needle placement using a longitudinal in-plane distal to proximal approach demonstrated spread of contrast material in the intended anatomic location with fluoroscopic confirmation in patients who underwent iliopsoas peritendon or bursa injection post total hip arthroplasty.</p><p><strong>Conclusion: </strong>Ultrasound guided needle placement using a longitudinal in-plane distal to proximal approach can be an effective alternative technique for diagnostic or therapeutic iliopsoas peritendon injection in patients with total hip arthroplasty.</p>","PeriodicalId":51528,"journal":{"name":"Journal of Ultrasound","volume":null,"pages":null},"PeriodicalIF":1.3000,"publicationDate":"2024-08-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Accuracy of ultrasound-guided iliopsoas tendon injection after total hip arthroplasty: a retrospective observational study.\",\"authors\":\"Matthew W Kaufman, Chantal Nguyen, Yue Meng, Eugene Roh\",\"doi\":\"10.1007/s40477-024-00904-w\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>To describe and characterize the accuracy and benefit of a technique for performing ultrasound-guided needle placement for iliopsoas peritendon or bursa injections as an alternative method to fluoroscopic guidance.</p><p><strong>Materials and methods: </strong>Patients with a history of total hip arthroplasty who were referred by their orthopedic surgeon for iliopsoas peritendon or bursa corticosteroid injection for iliopsoas impingement syndrome between June 2017 and December 2019 were eligible for inclusion. Of these patients, 19 received a total of 26 ultrasound-guided needle placement followed by confirmatory fluoroscopic guidance prior to injection. Pre-injection and post-injection VAS scores were collected to monitor pain. Additionally, the patients were followed for 6 months via chart review after their injection to assess for complications, need for repeat injections, and progression to surgical intervention. The accuracy of a longitudinal in-plane distal to proximal approach to ultrasound guided needle placement was then evaluated.</p><p><strong>Results: </strong>Ultrasound guided needle placement using a longitudinal in-plane distal to proximal approach demonstrated spread of contrast material in the intended anatomic location with fluoroscopic confirmation in patients who underwent iliopsoas peritendon or bursa injection post total hip arthroplasty.</p><p><strong>Conclusion: </strong>Ultrasound guided needle placement using a longitudinal in-plane distal to proximal approach can be an effective alternative technique for diagnostic or therapeutic iliopsoas peritendon injection in patients with total hip arthroplasty.</p>\",\"PeriodicalId\":51528,\"journal\":{\"name\":\"Journal of Ultrasound\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.3000,\"publicationDate\":\"2024-08-06\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Ultrasound\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1007/s40477-024-00904-w\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Ultrasound","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1007/s40477-024-00904-w","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

摘要

目的:描述并描述超声引导下髂腰肌腱膜或滑囊注射针头置入技术的准确性和益处,作为透视引导的替代方法:2017年6月至2019年12月期间,有全髋关节置换术史的患者经骨科医生转诊,因髂腰肌撞击综合征接受髂腰肌腱膜或滑囊皮质类固醇注射,符合纳入条件。在这些患者中,19 名患者共接受了 26 次超声引导下的针头置入,随后在注射前进行了确认性透视引导。收集了注射前和注射后的 VAS 评分,以监测疼痛情况。此外,注射后还通过病历审查对患者进行了为期 6 个月的随访,以评估并发症、重复注射的需要以及手术干预的进展情况。然后评估了在超声引导下从远端到近端纵向平面内进针的准确性:结果:在全髋关节置换术后接受髂腰肌腱膜或滑囊注射的患者中,使用平面内远端至近端纵向方法进行超声引导下的针头置放显示造影剂在预定解剖位置扩散,并经透视确认:结论:在超声引导下,使用平面内远端至近端纵向进针法可作为诊断或治疗全髋关节置换术患者髂腰肌腱周围注射的有效替代技术。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Accuracy of ultrasound-guided iliopsoas tendon injection after total hip arthroplasty: a retrospective observational study.

Purpose: To describe and characterize the accuracy and benefit of a technique for performing ultrasound-guided needle placement for iliopsoas peritendon or bursa injections as an alternative method to fluoroscopic guidance.

Materials and methods: Patients with a history of total hip arthroplasty who were referred by their orthopedic surgeon for iliopsoas peritendon or bursa corticosteroid injection for iliopsoas impingement syndrome between June 2017 and December 2019 were eligible for inclusion. Of these patients, 19 received a total of 26 ultrasound-guided needle placement followed by confirmatory fluoroscopic guidance prior to injection. Pre-injection and post-injection VAS scores were collected to monitor pain. Additionally, the patients were followed for 6 months via chart review after their injection to assess for complications, need for repeat injections, and progression to surgical intervention. The accuracy of a longitudinal in-plane distal to proximal approach to ultrasound guided needle placement was then evaluated.

Results: Ultrasound guided needle placement using a longitudinal in-plane distal to proximal approach demonstrated spread of contrast material in the intended anatomic location with fluoroscopic confirmation in patients who underwent iliopsoas peritendon or bursa injection post total hip arthroplasty.

Conclusion: Ultrasound guided needle placement using a longitudinal in-plane distal to proximal approach can be an effective alternative technique for diagnostic or therapeutic iliopsoas peritendon injection in patients with total hip arthroplasty.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of Ultrasound
Journal of Ultrasound RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING-
CiteScore
4.10
自引率
15.00%
发文量
133
期刊介绍: The Journal of Ultrasound is the official journal of the Italian Society for Ultrasound in Medicine and Biology (SIUMB). The journal publishes original contributions (research and review articles, case reports, technical reports and letters to the editor) on significant advances in clinical diagnostic, interventional and therapeutic applications, clinical techniques, the physics, engineering and technology of ultrasound in medicine and biology, and in cross-sectional diagnostic imaging. The official language of Journal of Ultrasound is English.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信