Tiago Bilhim, Nuno Vasco Costa, Daniel Torres, Serhat Akış, Marta Alves, Ana Luisa Papoila
{"title":"比较用于前列腺动脉栓塞治疗良性前列腺增生患者下尿路症状的栓塞颗粒。","authors":"Tiago Bilhim, Nuno Vasco Costa, Daniel Torres, Serhat Akış, Marta Alves, Ana Luisa Papoila","doi":"10.1007/s00330-024-10998-9","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>Compare the safety and efficacy of polyvinyl alcohol particles (PVA) versus trisacryl gelatin microspheres (Embospheres) versus hydrogel microspheres coated with polyzene-F (Embozenes) for prostatic artery embolization (PAE) to treat patients with benign prostatic hyperplasia (BPH).</p><p><strong>Materials and methods: </strong>A single-center prospective cohort study from 2019 to 2023, including patients with international prostate symptom score (IPSS) ≥ 15 and/or quality of life score (QoL) ≥ 4. Allocation to embolic agents was performed chronologically: 100-300 µm PVA (n = 53), followed by 300-500 µm Embospheres (n = 50), and finally, 400 µm Embozenes (n = 50). All patients were evaluated at baseline and at 1 and 6 months after PAE with IPSS/QoL; peak urinary flow rate, post-void residual volume, and prostate volume with ultrasound and prostate-specific antigen. Adverse events and the need for prostatic re-interventions were assessed.</p><p><strong>Results: </strong>There were no significant baseline differences between the three groups except for patient age (62.5 years PVA; 66.1 years Embospheres and 66.6 years Embozenes; p = 0.019). There were no major adverse events and no differences between groups regarding minor adverse events. All outcome measures improved significantly from baseline, with no significant differences between groups. Mean ± standard deviation IPSS/QoL improvement at 6 months: -10.7 ± 7.9/-2.2 ± 1.7 PVA; -10.4 ± 7.3/-2.0 ± 1.5 Embospheres; -10.4 ± 7.0/-2.2 ± 1.6 Embozenes (p = 0.987). Re-intervention rates after 6 months: 9% (n = 5/53) PVA; 14% (n = 7/50) Embospheres; 8% (n = 4/50) Embozenes (p = 0.591).</p><p><strong>Conclusions: </strong>PAE with PVA particles, Embospheres, and Embozenes is equally safe and effective in treating BPH-related lower urinary tract symptoms.</p><p><strong>Clinical relevance statement: </strong>This is the first prospective study showing equivalence between the most frequently used embolic agents for prostatic artery embolization.</p><p><strong>Key points: </strong>Different particles can be used interchangeably for prostatic artery embolization. The improvements in measured metrics were the same between groups, with no differences in adverse events. The need for prostatic medication and re-intervention rates were the same at 1 and 6 months after embolization.</p>","PeriodicalId":12076,"journal":{"name":"European Radiology","volume":" ","pages":"1057-1066"},"PeriodicalIF":4.7000,"publicationDate":"2025-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Comparing embolic particles for prostatic artery embolization to treat lower urinary tract symptoms in patients with benign prostatic hyperplasia.\",\"authors\":\"Tiago Bilhim, Nuno Vasco Costa, Daniel Torres, Serhat Akış, Marta Alves, Ana Luisa Papoila\",\"doi\":\"10.1007/s00330-024-10998-9\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>Compare the safety and efficacy of polyvinyl alcohol particles (PVA) versus trisacryl gelatin microspheres (Embospheres) versus hydrogel microspheres coated with polyzene-F (Embozenes) for prostatic artery embolization (PAE) to treat patients with benign prostatic hyperplasia (BPH).</p><p><strong>Materials and methods: </strong>A single-center prospective cohort study from 2019 to 2023, including patients with international prostate symptom score (IPSS) ≥ 15 and/or quality of life score (QoL) ≥ 4. Allocation to embolic agents was performed chronologically: 100-300 µm PVA (n = 53), followed by 300-500 µm Embospheres (n = 50), and finally, 400 µm Embozenes (n = 50). All patients were evaluated at baseline and at 1 and 6 months after PAE with IPSS/QoL; peak urinary flow rate, post-void residual volume, and prostate volume with ultrasound and prostate-specific antigen. Adverse events and the need for prostatic re-interventions were assessed.</p><p><strong>Results: </strong>There were no significant baseline differences between the three groups except for patient age (62.5 years PVA; 66.1 years Embospheres and 66.6 years Embozenes; p = 0.019). There were no major adverse events and no differences between groups regarding minor adverse events. All outcome measures improved significantly from baseline, with no significant differences between groups. Mean ± standard deviation IPSS/QoL improvement at 6 months: -10.7 ± 7.9/-2.2 ± 1.7 PVA; -10.4 ± 7.3/-2.0 ± 1.5 Embospheres; -10.4 ± 7.0/-2.2 ± 1.6 Embozenes (p = 0.987). Re-intervention rates after 6 months: 9% (n = 5/53) PVA; 14% (n = 7/50) Embospheres; 8% (n = 4/50) Embozenes (p = 0.591).</p><p><strong>Conclusions: </strong>PAE with PVA particles, Embospheres, and Embozenes is equally safe and effective in treating BPH-related lower urinary tract symptoms.</p><p><strong>Clinical relevance statement: </strong>This is the first prospective study showing equivalence between the most frequently used embolic agents for prostatic artery embolization.</p><p><strong>Key points: </strong>Different particles can be used interchangeably for prostatic artery embolization. The improvements in measured metrics were the same between groups, with no differences in adverse events. The need for prostatic medication and re-intervention rates were the same at 1 and 6 months after embolization.</p>\",\"PeriodicalId\":12076,\"journal\":{\"name\":\"European Radiology\",\"volume\":\" \",\"pages\":\"1057-1066\"},\"PeriodicalIF\":4.7000,\"publicationDate\":\"2025-02-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"European Radiology\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1007/s00330-024-10998-9\",\"RegionNum\":2,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/8/6 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q1\",\"JCRName\":\"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"European Radiology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s00330-024-10998-9","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/8/6 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
Comparing embolic particles for prostatic artery embolization to treat lower urinary tract symptoms in patients with benign prostatic hyperplasia.
Purpose: Compare the safety and efficacy of polyvinyl alcohol particles (PVA) versus trisacryl gelatin microspheres (Embospheres) versus hydrogel microspheres coated with polyzene-F (Embozenes) for prostatic artery embolization (PAE) to treat patients with benign prostatic hyperplasia (BPH).
Materials and methods: A single-center prospective cohort study from 2019 to 2023, including patients with international prostate symptom score (IPSS) ≥ 15 and/or quality of life score (QoL) ≥ 4. Allocation to embolic agents was performed chronologically: 100-300 µm PVA (n = 53), followed by 300-500 µm Embospheres (n = 50), and finally, 400 µm Embozenes (n = 50). All patients were evaluated at baseline and at 1 and 6 months after PAE with IPSS/QoL; peak urinary flow rate, post-void residual volume, and prostate volume with ultrasound and prostate-specific antigen. Adverse events and the need for prostatic re-interventions were assessed.
Results: There were no significant baseline differences between the three groups except for patient age (62.5 years PVA; 66.1 years Embospheres and 66.6 years Embozenes; p = 0.019). There were no major adverse events and no differences between groups regarding minor adverse events. All outcome measures improved significantly from baseline, with no significant differences between groups. Mean ± standard deviation IPSS/QoL improvement at 6 months: -10.7 ± 7.9/-2.2 ± 1.7 PVA; -10.4 ± 7.3/-2.0 ± 1.5 Embospheres; -10.4 ± 7.0/-2.2 ± 1.6 Embozenes (p = 0.987). Re-intervention rates after 6 months: 9% (n = 5/53) PVA; 14% (n = 7/50) Embospheres; 8% (n = 4/50) Embozenes (p = 0.591).
Conclusions: PAE with PVA particles, Embospheres, and Embozenes is equally safe and effective in treating BPH-related lower urinary tract symptoms.
Clinical relevance statement: This is the first prospective study showing equivalence between the most frequently used embolic agents for prostatic artery embolization.
Key points: Different particles can be used interchangeably for prostatic artery embolization. The improvements in measured metrics were the same between groups, with no differences in adverse events. The need for prostatic medication and re-intervention rates were the same at 1 and 6 months after embolization.
期刊介绍:
European Radiology (ER) continuously updates scientific knowledge in radiology by publication of strong original articles and state-of-the-art reviews written by leading radiologists. A well balanced combination of review articles, original papers, short communications from European radiological congresses and information on society matters makes ER an indispensable source for current information in this field.
This is the Journal of the European Society of Radiology, and the official journal of a number of societies.
From 2004-2008 supplements to European Radiology were published under its companion, European Radiology Supplements, ISSN 1613-3749.