Alessandro Cucchi, Gregorio Marchiori, Maria Sartori, Milena Fini, Antonino Fiorino, Raffaele Donati, Giuseppe Corinaldesi, Melania Maglio
{"title":"使用 CAD/CAM 定制钛网进行垂直和水平牙槽嵴增高术后骨组织成分和结构的三维显微 CT 评估。","authors":"Alessandro Cucchi, Gregorio Marchiori, Maria Sartori, Milena Fini, Antonino Fiorino, Raffaele Donati, Giuseppe Corinaldesi, Melania Maglio","doi":"10.1111/clr.14342","DOIUrl":null,"url":null,"abstract":"<div>\n \n \n <section>\n \n <h3> Objectives</h3>\n \n <p>To date, no studies have exploited micro-CT in humans to evaluate bone morphology and structure after bone augmentation with CAD/CAM-customized titanium mesh, in mandible and maxilla. The aim of this study was to assess the composition and microstructure of bone biopsy through micro-CT analysis.</p>\n </section>\n \n <section>\n \n <h3> Materials and Methods</h3>\n \n <p>Bone augmentation at both maxillary and mandible sites was performed on 30 patients randomly treated with customized mesh, either alone (M−) or covered with resorbable membrane (M+), in both cases filled 50:50 with autogenous bone and xenograft. After 6 months, biopsies were taken and micro-CT was performed on consecutive 1-mm-thick VOIs from coronal to apical side, measuring tissue volumes, trabecular thickness, spacing, and number.</p>\n </section>\n \n <section>\n \n <h3> Results</h3>\n \n <p>In both groups, irrespective of membrane use, bone tissue (M−: 29.76% vs. M+: 30.84%) and residual graft material (M−: 14.87% vs. M+: 13.11%) values were similar. Differences were site-related (maxillary vs. mandibular) with higher percentage of bone tissue and trabecular density of low-mineralized bone and overall bone in the mandible.</p>\n </section>\n \n <section>\n \n <h3> Conclusions</h3>\n \n <p>The composition and structure of bone tissue, as assessed by micro-CT after alveolar ridge augmentation using CAD/CAM-customized titanium meshes, showed similar features regardless of whether a collagen membrane was applied.</p>\n </section>\n </div>","PeriodicalId":10455,"journal":{"name":"Clinical Oral Implants Research","volume":"35 12","pages":"1546-1559"},"PeriodicalIF":4.8000,"publicationDate":"2024-08-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11629439/pdf/","citationCount":"0","resultStr":"{\"title\":\"A 3D micro-CT assessment of composition and structure of bone tissue after vertical and horizontal alveolar ridge augmentation using CAD/CAM-customized titanium mesh\",\"authors\":\"Alessandro Cucchi, Gregorio Marchiori, Maria Sartori, Milena Fini, Antonino Fiorino, Raffaele Donati, Giuseppe Corinaldesi, Melania Maglio\",\"doi\":\"10.1111/clr.14342\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div>\\n \\n \\n <section>\\n \\n <h3> Objectives</h3>\\n \\n <p>To date, no studies have exploited micro-CT in humans to evaluate bone morphology and structure after bone augmentation with CAD/CAM-customized titanium mesh, in mandible and maxilla. The aim of this study was to assess the composition and microstructure of bone biopsy through micro-CT analysis.</p>\\n </section>\\n \\n <section>\\n \\n <h3> Materials and Methods</h3>\\n \\n <p>Bone augmentation at both maxillary and mandible sites was performed on 30 patients randomly treated with customized mesh, either alone (M−) or covered with resorbable membrane (M+), in both cases filled 50:50 with autogenous bone and xenograft. After 6 months, biopsies were taken and micro-CT was performed on consecutive 1-mm-thick VOIs from coronal to apical side, measuring tissue volumes, trabecular thickness, spacing, and number.</p>\\n </section>\\n \\n <section>\\n \\n <h3> Results</h3>\\n \\n <p>In both groups, irrespective of membrane use, bone tissue (M−: 29.76% vs. M+: 30.84%) and residual graft material (M−: 14.87% vs. M+: 13.11%) values were similar. Differences were site-related (maxillary vs. mandibular) with higher percentage of bone tissue and trabecular density of low-mineralized bone and overall bone in the mandible.</p>\\n </section>\\n \\n <section>\\n \\n <h3> Conclusions</h3>\\n \\n <p>The composition and structure of bone tissue, as assessed by micro-CT after alveolar ridge augmentation using CAD/CAM-customized titanium meshes, showed similar features regardless of whether a collagen membrane was applied.</p>\\n </section>\\n </div>\",\"PeriodicalId\":10455,\"journal\":{\"name\":\"Clinical Oral Implants Research\",\"volume\":\"35 12\",\"pages\":\"1546-1559\"},\"PeriodicalIF\":4.8000,\"publicationDate\":\"2024-08-06\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11629439/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Clinical Oral Implants Research\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://onlinelibrary.wiley.com/doi/10.1111/clr.14342\",\"RegionNum\":1,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"DENTISTRY, ORAL SURGERY & MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Clinical Oral Implants Research","FirstCategoryId":"5","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1111/clr.14342","RegionNum":1,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0
摘要
目的:迄今为止,还没有研究利用显微 CT 评估下颌骨和上颌骨使用 CAD/CAM 定制钛网进行骨增量后的骨形态和结构。本研究旨在通过显微 CT 分析评估骨活检的成分和微观结构:对 30 名患者随机进行了上颌和下颌部位的骨增量手术,这些患者要么单独使用定制网片(M-),要么使用可吸收膜覆盖(M+),在这两种情况下,自体骨和异种移植骨的填充比例均为 50:50。6 个月后,采集活组织切片,并从冠状面到顶端对连续的 1 毫米厚的 VOI 进行显微 CT 扫描,测量组织体积、骨小梁厚度、间距和数量:在两组中,无论使用何种膜,骨组织(M-:29.76% vs. M+:30.84%)和残留移植材料(M-:14.87% vs. M+:13.11%)的值相似。差异与部位有关(上颌与下颌),下颌的骨组织百分比和低矿化骨小梁密度以及整体骨质更高:使用 CAD/CAM 定制钛网进行牙槽嵴增量术后,通过显微 CT 评估的骨组织组成和结构显示出相似的特征,无论是否应用胶原蛋白膜。
A 3D micro-CT assessment of composition and structure of bone tissue after vertical and horizontal alveolar ridge augmentation using CAD/CAM-customized titanium mesh
Objectives
To date, no studies have exploited micro-CT in humans to evaluate bone morphology and structure after bone augmentation with CAD/CAM-customized titanium mesh, in mandible and maxilla. The aim of this study was to assess the composition and microstructure of bone biopsy through micro-CT analysis.
Materials and Methods
Bone augmentation at both maxillary and mandible sites was performed on 30 patients randomly treated with customized mesh, either alone (M−) or covered with resorbable membrane (M+), in both cases filled 50:50 with autogenous bone and xenograft. After 6 months, biopsies were taken and micro-CT was performed on consecutive 1-mm-thick VOIs from coronal to apical side, measuring tissue volumes, trabecular thickness, spacing, and number.
Results
In both groups, irrespective of membrane use, bone tissue (M−: 29.76% vs. M+: 30.84%) and residual graft material (M−: 14.87% vs. M+: 13.11%) values were similar. Differences were site-related (maxillary vs. mandibular) with higher percentage of bone tissue and trabecular density of low-mineralized bone and overall bone in the mandible.
Conclusions
The composition and structure of bone tissue, as assessed by micro-CT after alveolar ridge augmentation using CAD/CAM-customized titanium meshes, showed similar features regardless of whether a collagen membrane was applied.
期刊介绍:
Clinical Oral Implants Research conveys scientific progress in the field of implant dentistry and its related areas to clinicians, teachers and researchers concerned with the application of this information for the benefit of patients in need of oral implants. The journal addresses itself to clinicians, general practitioners, periodontists, oral and maxillofacial surgeons and prosthodontists, as well as to teachers, academicians and scholars involved in the education of professionals and in the scientific promotion of the field of implant dentistry.