Dominic P. Recco, Shannen B. Kizilski, Wen Zhang, Nicholas E. Kneier, Patrick D. Earley, David M. Hoganson, Christopher W. Baird, Peter E. Hammer
{"title":"开发简易分析模型,为主动脉根部瓣膜置换术的术前手术规划提供便利。","authors":"Dominic P. Recco, Shannen B. Kizilski, Wen Zhang, Nicholas E. Kneier, Patrick D. Earley, David M. Hoganson, Christopher W. Baird, Peter E. Hammer","doi":"10.1007/s10439-024-03593-y","DOIUrl":null,"url":null,"abstract":"<div><h3>Purpose</h3><p>Valve-sparing root replacement (VSRR) is attractive for aortic root dilation as it preserves the native aortic valve (AoV). Low effective height (eH) after reconstruction is a risk factor for repair failure and reoperation. We developed and validated a quantitative AoV repair strategy to reliably restore normal valve proportions to promote long-term function.</p><h3>Methods</h3><p>Normal AoV proportions were used to derive geometric relationships for sinotubular junction diameter (D<sub>STJ</sub>), free edge length (FEL), free edge angle, and commissure height. These relationships informed two models for predicting eH following VSRR: (1) assuming valve symmetry and (2) accounting for valve asymmetry. Porcine heart (<i>n</i> = 6) ex vivo validation was performed under 4 VSRR scenarios: “Ideal” (tube graft size targeting FEL/D<sub>STJ</sub> = 1.28), “Oversized” (one graft size larger than Ideal), “Undersized” (two sizes smaller), and “Undersized + Plicated” (FEL/D<sub>STJ</sub> = 1.28 restored with leaflet plication).</p><h3>Results</h3><p>Our analytical models predicted eH using preoperative measurements and estimated reconstructed dimensions. The Oversized graft exhibited similar eH to Ideal but higher regurgitation in the ex vivo model, whereas the Undersized graft demonstrated lower eH and regurgitation. Plication in the Undersized graft restored valve function (regurgitation & eH) similar to Ideal in the ex vivo model and above Ideal in the analytical models. Both analytical models predicted ex vivo eH well except in the Oversized and Undersized + Plicated conditions.</p><h3>Conclusion</h3><p>Utilizing measurements from preoperative imaging and simple mathematical models, patient-specific operative plans for VSRR can be created by estimating valve dimensions necessary to achieve favorable valve features post-repair. Clinical application of this approach promises to improve consistency in achieving optimal long-term dimensions and durability.</p></div>","PeriodicalId":7986,"journal":{"name":"Annals of Biomedical Engineering","volume":"52 12","pages":"3264 - 3279"},"PeriodicalIF":3.0000,"publicationDate":"2024-08-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Development of a Simple Analytical Model to Facilitate Preoperative Surgical Planning in Valve-Sparing Aortic Root Replacement\",\"authors\":\"Dominic P. Recco, Shannen B. Kizilski, Wen Zhang, Nicholas E. Kneier, Patrick D. Earley, David M. Hoganson, Christopher W. Baird, Peter E. Hammer\",\"doi\":\"10.1007/s10439-024-03593-y\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><h3>Purpose</h3><p>Valve-sparing root replacement (VSRR) is attractive for aortic root dilation as it preserves the native aortic valve (AoV). Low effective height (eH) after reconstruction is a risk factor for repair failure and reoperation. We developed and validated a quantitative AoV repair strategy to reliably restore normal valve proportions to promote long-term function.</p><h3>Methods</h3><p>Normal AoV proportions were used to derive geometric relationships for sinotubular junction diameter (D<sub>STJ</sub>), free edge length (FEL), free edge angle, and commissure height. These relationships informed two models for predicting eH following VSRR: (1) assuming valve symmetry and (2) accounting for valve asymmetry. Porcine heart (<i>n</i> = 6) ex vivo validation was performed under 4 VSRR scenarios: “Ideal” (tube graft size targeting FEL/D<sub>STJ</sub> = 1.28), “Oversized” (one graft size larger than Ideal), “Undersized” (two sizes smaller), and “Undersized + Plicated” (FEL/D<sub>STJ</sub> = 1.28 restored with leaflet plication).</p><h3>Results</h3><p>Our analytical models predicted eH using preoperative measurements and estimated reconstructed dimensions. The Oversized graft exhibited similar eH to Ideal but higher regurgitation in the ex vivo model, whereas the Undersized graft demonstrated lower eH and regurgitation. Plication in the Undersized graft restored valve function (regurgitation & eH) similar to Ideal in the ex vivo model and above Ideal in the analytical models. Both analytical models predicted ex vivo eH well except in the Oversized and Undersized + Plicated conditions.</p><h3>Conclusion</h3><p>Utilizing measurements from preoperative imaging and simple mathematical models, patient-specific operative plans for VSRR can be created by estimating valve dimensions necessary to achieve favorable valve features post-repair. Clinical application of this approach promises to improve consistency in achieving optimal long-term dimensions and durability.</p></div>\",\"PeriodicalId\":7986,\"journal\":{\"name\":\"Annals of Biomedical Engineering\",\"volume\":\"52 12\",\"pages\":\"3264 - 3279\"},\"PeriodicalIF\":3.0000,\"publicationDate\":\"2024-08-06\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Annals of Biomedical Engineering\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://link.springer.com/article/10.1007/s10439-024-03593-y\",\"RegionNum\":2,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"ENGINEERING, BIOMEDICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Annals of Biomedical Engineering","FirstCategoryId":"5","ListUrlMain":"https://link.springer.com/article/10.1007/s10439-024-03593-y","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
Development of a Simple Analytical Model to Facilitate Preoperative Surgical Planning in Valve-Sparing Aortic Root Replacement
Purpose
Valve-sparing root replacement (VSRR) is attractive for aortic root dilation as it preserves the native aortic valve (AoV). Low effective height (eH) after reconstruction is a risk factor for repair failure and reoperation. We developed and validated a quantitative AoV repair strategy to reliably restore normal valve proportions to promote long-term function.
Methods
Normal AoV proportions were used to derive geometric relationships for sinotubular junction diameter (DSTJ), free edge length (FEL), free edge angle, and commissure height. These relationships informed two models for predicting eH following VSRR: (1) assuming valve symmetry and (2) accounting for valve asymmetry. Porcine heart (n = 6) ex vivo validation was performed under 4 VSRR scenarios: “Ideal” (tube graft size targeting FEL/DSTJ = 1.28), “Oversized” (one graft size larger than Ideal), “Undersized” (two sizes smaller), and “Undersized + Plicated” (FEL/DSTJ = 1.28 restored with leaflet plication).
Results
Our analytical models predicted eH using preoperative measurements and estimated reconstructed dimensions. The Oversized graft exhibited similar eH to Ideal but higher regurgitation in the ex vivo model, whereas the Undersized graft demonstrated lower eH and regurgitation. Plication in the Undersized graft restored valve function (regurgitation & eH) similar to Ideal in the ex vivo model and above Ideal in the analytical models. Both analytical models predicted ex vivo eH well except in the Oversized and Undersized + Plicated conditions.
Conclusion
Utilizing measurements from preoperative imaging and simple mathematical models, patient-specific operative plans for VSRR can be created by estimating valve dimensions necessary to achieve favorable valve features post-repair. Clinical application of this approach promises to improve consistency in achieving optimal long-term dimensions and durability.
期刊介绍:
Annals of Biomedical Engineering is an official journal of the Biomedical Engineering Society, publishing original articles in the major fields of bioengineering and biomedical engineering. The Annals is an interdisciplinary and international journal with the aim to highlight integrated approaches to the solutions of biological and biomedical problems.