加强自体筋膜吊带术:治疗女性压力性尿失禁的新型固定方法。

Yu-Kai Huang, Yu-Hua Fan, Alex Tong-Long Lin, William J Huang, Chih-Chieh Lin
{"title":"加强自体筋膜吊带术:治疗女性压力性尿失禁的新型固定方法。","authors":"Yu-Kai Huang, Yu-Hua Fan, Alex Tong-Long Lin, William J Huang, Chih-Chieh Lin","doi":"10.1097/JCMA.0000000000001141","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Synthetic mid-urethral sling surgery has long been the standard surgical treatment for stress urinary incontinence (SUI) worldwide. Using an autologous fascial sling is an alternative to reduce adverse events. We evaluated the treatment outcomes of a novel fixation method applied to the autologous transobturator fascial (TOF) sling procedure for female patients with SUI.</p><p><strong>Methods: </strong>A retrospective study was conducted between 2017 and 2020, including 33 patients with SUI who underwent mid-urethral TOF sling surgery with the novel fixation method. We used a self-locking feature (V-LOC™) that was fixed to each side of skin layer above the obturator foramen, and the tension of the fascia sling was adjusted by manipulating the V-LOC™ suture. We analyzed all data collected through questionnaires, including Urinary Distress Inventory-Short Form (UDI-6), Incontinence Impact Questionnaire-Short Form (IIQ-7), Overactive Bladder Symptom Score (OABSS), and Clinical Global Impressions of Improvement (CGI-I). Adverse events were also recorded.</p><p><strong>Results: </strong>This study included 33 female patients aged 39 to 79 (mean 59.76 years). Following the procedure, there was a significant reduction in the total scores of UDI-6, IIQ-7, and OABSS (preoperative 9.73 ± 4.35, 10.21 ± 5.79, 6.06 ± 4.03 and postoperative 3.52 ± 3.41, 0.85 ± 3.67, 3.06 ± 2.90, respectively) ( p < 0.001). Further analysis of each sub-score of the questionnaires revealed significant improvement in certain symptoms. The mean total score of CGI-I was 2.00 ± 0.80. The maximum flow rate was documented for 18 patients, and no significant reduction was observed after the procedure ( p = 0.804). Complications reported included voiding dysfunction in two patients (6.1%), inguinal pain in one patient (3.0%), and mild delayed wound healing in one patient (3.0%).</p><p><strong>Conclusion: </strong>This modified TOF sling surgery with a novel fixation method by V-LOC™ suture offers feasibility and adjustability as its main advantages. Our study demonstrated significant improvements in patient outcomes.</p>","PeriodicalId":94115,"journal":{"name":"Journal of the Chinese Medical Association : JCMA","volume":" ","pages":"940-944"},"PeriodicalIF":0.0000,"publicationDate":"2024-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Enhancing the autologous fascial sling procedure: A novel fixation method for treating stress urinary incontinence in female patients.\",\"authors\":\"Yu-Kai Huang, Yu-Hua Fan, Alex Tong-Long Lin, William J Huang, Chih-Chieh Lin\",\"doi\":\"10.1097/JCMA.0000000000001141\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>Synthetic mid-urethral sling surgery has long been the standard surgical treatment for stress urinary incontinence (SUI) worldwide. Using an autologous fascial sling is an alternative to reduce adverse events. We evaluated the treatment outcomes of a novel fixation method applied to the autologous transobturator fascial (TOF) sling procedure for female patients with SUI.</p><p><strong>Methods: </strong>A retrospective study was conducted between 2017 and 2020, including 33 patients with SUI who underwent mid-urethral TOF sling surgery with the novel fixation method. We used a self-locking feature (V-LOC™) that was fixed to each side of skin layer above the obturator foramen, and the tension of the fascia sling was adjusted by manipulating the V-LOC™ suture. We analyzed all data collected through questionnaires, including Urinary Distress Inventory-Short Form (UDI-6), Incontinence Impact Questionnaire-Short Form (IIQ-7), Overactive Bladder Symptom Score (OABSS), and Clinical Global Impressions of Improvement (CGI-I). Adverse events were also recorded.</p><p><strong>Results: </strong>This study included 33 female patients aged 39 to 79 (mean 59.76 years). Following the procedure, there was a significant reduction in the total scores of UDI-6, IIQ-7, and OABSS (preoperative 9.73 ± 4.35, 10.21 ± 5.79, 6.06 ± 4.03 and postoperative 3.52 ± 3.41, 0.85 ± 3.67, 3.06 ± 2.90, respectively) ( p < 0.001). Further analysis of each sub-score of the questionnaires revealed significant improvement in certain symptoms. The mean total score of CGI-I was 2.00 ± 0.80. The maximum flow rate was documented for 18 patients, and no significant reduction was observed after the procedure ( p = 0.804). Complications reported included voiding dysfunction in two patients (6.1%), inguinal pain in one patient (3.0%), and mild delayed wound healing in one patient (3.0%).</p><p><strong>Conclusion: </strong>This modified TOF sling surgery with a novel fixation method by V-LOC™ suture offers feasibility and adjustability as its main advantages. Our study demonstrated significant improvements in patient outcomes.</p>\",\"PeriodicalId\":94115,\"journal\":{\"name\":\"Journal of the Chinese Medical Association : JCMA\",\"volume\":\" \",\"pages\":\"940-944\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of the Chinese Medical Association : JCMA\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1097/JCMA.0000000000001141\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/8/6 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of the Chinese Medical Association : JCMA","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1097/JCMA.0000000000001141","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/8/6 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

背景:长期以来,合成尿道中段吊带手术一直是全世界治疗压力性尿失禁(SUI)的标准手术疗法。使用自体筋膜吊带是减少不良反应的一种替代方法。我们评估了应用于自体经尿道筋膜(TOF)吊带术的新型固定方法对女性 SUI 患者的治疗效果:我们在2017年至2020年期间进行了一项回顾性研究,其中包括33名使用新型固定方法接受尿道中段TOF吊带手术的SUI患者。我们使用了自锁功能(V-LOC™),将其分别固定在闭孔上方的两侧皮肤层上,通过操作V-LOC™缝合线来调节筋膜吊带的张力。我们分析了通过调查问卷收集到的所有数据,包括尿压力量表-短表(UDI-6)、尿失禁影响问卷-短表(IIQ-7)、膀胱过度活动症状评分(OABSS)和临床整体改善印象(CGI-I)。此外,还记录了不良事件:这项研究包括 33 名女性患者,年龄在 39-79 岁之间(平均 59.76 岁)。术后,UDI-6、IIQ-7 和 OABSS 的总分显著降低(术前分别为 9.73±4.35、10.21±5.79、6.06±4.03,术后分别为 3.52±3.41、0.85±3.67、3.06±2.90)(P < 0.001)。对问卷各分项的进一步分析表明,某些症状有明显改善。CGI-I 的平均总分为 2.00 ± 0.80。18 名患者的最大流量均有记录,术后未发现明显降低(p = 0.804)。并发症包括两名患者(6.1%)出现排尿功能障碍,一名患者(3.0%)出现腹股沟疼痛,一名患者(3.0%)出现轻度伤口延迟愈合:这种改良的TOF吊带手术采用V-LOC™缝合线的新型固定方法,其主要优点是具有可行性和可调性。我们的研究结果表明,患者的治疗效果明显改善。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Enhancing the autologous fascial sling procedure: A novel fixation method for treating stress urinary incontinence in female patients.

Background: Synthetic mid-urethral sling surgery has long been the standard surgical treatment for stress urinary incontinence (SUI) worldwide. Using an autologous fascial sling is an alternative to reduce adverse events. We evaluated the treatment outcomes of a novel fixation method applied to the autologous transobturator fascial (TOF) sling procedure for female patients with SUI.

Methods: A retrospective study was conducted between 2017 and 2020, including 33 patients with SUI who underwent mid-urethral TOF sling surgery with the novel fixation method. We used a self-locking feature (V-LOC™) that was fixed to each side of skin layer above the obturator foramen, and the tension of the fascia sling was adjusted by manipulating the V-LOC™ suture. We analyzed all data collected through questionnaires, including Urinary Distress Inventory-Short Form (UDI-6), Incontinence Impact Questionnaire-Short Form (IIQ-7), Overactive Bladder Symptom Score (OABSS), and Clinical Global Impressions of Improvement (CGI-I). Adverse events were also recorded.

Results: This study included 33 female patients aged 39 to 79 (mean 59.76 years). Following the procedure, there was a significant reduction in the total scores of UDI-6, IIQ-7, and OABSS (preoperative 9.73 ± 4.35, 10.21 ± 5.79, 6.06 ± 4.03 and postoperative 3.52 ± 3.41, 0.85 ± 3.67, 3.06 ± 2.90, respectively) ( p < 0.001). Further analysis of each sub-score of the questionnaires revealed significant improvement in certain symptoms. The mean total score of CGI-I was 2.00 ± 0.80. The maximum flow rate was documented for 18 patients, and no significant reduction was observed after the procedure ( p = 0.804). Complications reported included voiding dysfunction in two patients (6.1%), inguinal pain in one patient (3.0%), and mild delayed wound healing in one patient (3.0%).

Conclusion: This modified TOF sling surgery with a novel fixation method by V-LOC™ suture offers feasibility and adjustability as its main advantages. Our study demonstrated significant improvements in patient outcomes.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信