乳腺多参数超声:单中心经验。

IF 1.3 Q3 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
Journal of Ultrasound Pub Date : 2024-12-01 Epub Date: 2024-08-05 DOI:10.1007/s40477-024-00944-2
Calogero Zarcaro, Alessia Angela Maria Orlando, Fabiola Ferraro, Simona Donia, Arianna Melita, Giuseppe Micci, Roberto Cannella, Tommaso Vincenzo Bartolotta
{"title":"乳腺多参数超声:单中心经验。","authors":"Calogero Zarcaro, Alessia Angela Maria Orlando, Fabiola Ferraro, Simona Donia, Arianna Melita, Giuseppe Micci, Roberto Cannella, Tommaso Vincenzo Bartolotta","doi":"10.1007/s40477-024-00944-2","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To evaluate the role of multiparametric ultrasound (mpUS) in the characterization of focal breast lesions (FBLs).</p><p><strong>Methods: </strong>This prospective study enrolled patients undergoing multiparametric breast ultrasound for FBLs. An experienced breast radiologist evaluated the following ultrasound features: US BI-RADS category, vascularization pattern (internal, vessels in rim and combined) and presence of penetrating vessels with each Doppler method (Color-Doppler, Power-Doppler, Microvascular imaging), strain ratio (SR) and Tsukuba score (TS) with Strain Elastography (SE), E<sub>max</sub>, E<sub>mean</sub>, E<sub>min</sub> and E<sub>ratio</sub> with 2D-shear wave elastography (2D-SWE). Core biopsy for all BI-RADS 4-5 FBLs and 24-month follow-up for all BI-RADS 2-3 FBLs were considered for standard of reference. The diagnostic performance was assessed with the area under curve (AUCs) and cut-off values were determined according to the Youden's index.</p><p><strong>Results: </strong>A total of 139 FBLs were included with 75/139 (53.9%) benign and 64/139 (46.1%) malignant FBLs. Internal vascularization patterns (p < 0.001), penetrating vessels (p < 0.001), TS 4-5 (p < 0.001) and all 2D-SWE parameters (p < 0.001) were significantly different between benign and malignant FBLs. The BI-RADS score provided an AUC of 0.876 (95% CI 0.810-0.926) for the diagnosis of malignant FBLs. Among the 2D-SWE measurements, an excellent diagnostic performance was observed for E<sub>max</sub> with an AUC of 0.915 (95% CI 0.856-0.956) and E<sub>mean</sub> of 0.908 (95% CI 0.847-0.951). Optimal cutoff for the diagnosis of malignant FBLs were US BI-RADS > 3, Strain Ratio > 2.52, Tsukuba Score > 3, E<sub>max</sub> > 82.6 kPa, E<sub>mean</sub> > 66.0 kPa, E<sub>min</sub> > 54.4 kPa and E<sub>ratio</sub> > 330.8. Multiparametric ultrasound, particularly SWE, can improve specificity in the characterization of FBLs.</p>","PeriodicalId":51528,"journal":{"name":"Journal of Ultrasound","volume":" ","pages":"831-839"},"PeriodicalIF":1.3000,"publicationDate":"2024-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11496459/pdf/","citationCount":"0","resultStr":"{\"title\":\"Breast multiparametric ultrasound: a single-center experience.\",\"authors\":\"Calogero Zarcaro, Alessia Angela Maria Orlando, Fabiola Ferraro, Simona Donia, Arianna Melita, Giuseppe Micci, Roberto Cannella, Tommaso Vincenzo Bartolotta\",\"doi\":\"10.1007/s40477-024-00944-2\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>To evaluate the role of multiparametric ultrasound (mpUS) in the characterization of focal breast lesions (FBLs).</p><p><strong>Methods: </strong>This prospective study enrolled patients undergoing multiparametric breast ultrasound for FBLs. An experienced breast radiologist evaluated the following ultrasound features: US BI-RADS category, vascularization pattern (internal, vessels in rim and combined) and presence of penetrating vessels with each Doppler method (Color-Doppler, Power-Doppler, Microvascular imaging), strain ratio (SR) and Tsukuba score (TS) with Strain Elastography (SE), E<sub>max</sub>, E<sub>mean</sub>, E<sub>min</sub> and E<sub>ratio</sub> with 2D-shear wave elastography (2D-SWE). Core biopsy for all BI-RADS 4-5 FBLs and 24-month follow-up for all BI-RADS 2-3 FBLs were considered for standard of reference. The diagnostic performance was assessed with the area under curve (AUCs) and cut-off values were determined according to the Youden's index.</p><p><strong>Results: </strong>A total of 139 FBLs were included with 75/139 (53.9%) benign and 64/139 (46.1%) malignant FBLs. Internal vascularization patterns (p < 0.001), penetrating vessels (p < 0.001), TS 4-5 (p < 0.001) and all 2D-SWE parameters (p < 0.001) were significantly different between benign and malignant FBLs. The BI-RADS score provided an AUC of 0.876 (95% CI 0.810-0.926) for the diagnosis of malignant FBLs. Among the 2D-SWE measurements, an excellent diagnostic performance was observed for E<sub>max</sub> with an AUC of 0.915 (95% CI 0.856-0.956) and E<sub>mean</sub> of 0.908 (95% CI 0.847-0.951). Optimal cutoff for the diagnosis of malignant FBLs were US BI-RADS > 3, Strain Ratio > 2.52, Tsukuba Score > 3, E<sub>max</sub> > 82.6 kPa, E<sub>mean</sub> > 66.0 kPa, E<sub>min</sub> > 54.4 kPa and E<sub>ratio</sub> > 330.8. Multiparametric ultrasound, particularly SWE, can improve specificity in the characterization of FBLs.</p>\",\"PeriodicalId\":51528,\"journal\":{\"name\":\"Journal of Ultrasound\",\"volume\":\" \",\"pages\":\"831-839\"},\"PeriodicalIF\":1.3000,\"publicationDate\":\"2024-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11496459/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Ultrasound\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1007/s40477-024-00944-2\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/8/5 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q3\",\"JCRName\":\"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Ultrasound","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1007/s40477-024-00944-2","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/8/5 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

摘要

目的:评估多参数超声(mpUS)在确定乳腺局灶性病变(FBLs)特征方面的作用:这项前瞻性研究招募了接受多参数乳腺超声检查的 FBLs 患者。一位经验丰富的乳腺放射科医生对以下超声特征进行了评估:美国 BI-RADS 分类、血管形态(内部血管、边缘血管和合并血管)、每种多普勒方法(彩色多普勒、动力多普勒、微血管成像)是否存在穿透性血管、应变弹性成像(SE)的应变比(SR)和筑波评分(TS)、二维剪切波弹性成像(2D-SWE)的Emax、Emean、Emin 和 Eratio。所有 BI-RADS 4-5 级 FBL 的核心活检和所有 BI-RADS 2-3 级 FBL 的 24 个月随访均被视为参考标准。诊断性能以曲线下面积(AUC)进行评估,并根据尤登指数确定临界值:结果:共纳入139个FBL,其中75/139(53.9%)为良性,64/139(46.1%)为恶性。内部血管化模式(p max)的AUC为0.915(95% CI为0.856-0.956),Emean为0.908(95% CI为0.847-0.951)。诊断恶性 FBL 的最佳临界值为:美国 BI-RADS > 3、应变比 > 2.52、筑波评分 > 3、Emax > 82.6 kPa、Emean > 66.0 kPa、Emin > 54.4 kPa 和 Eratio > 330.8。多参数超声,尤其是 SWE,可提高 FBLs 特征的特异性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Breast multiparametric ultrasound: a single-center experience.

Purpose: To evaluate the role of multiparametric ultrasound (mpUS) in the characterization of focal breast lesions (FBLs).

Methods: This prospective study enrolled patients undergoing multiparametric breast ultrasound for FBLs. An experienced breast radiologist evaluated the following ultrasound features: US BI-RADS category, vascularization pattern (internal, vessels in rim and combined) and presence of penetrating vessels with each Doppler method (Color-Doppler, Power-Doppler, Microvascular imaging), strain ratio (SR) and Tsukuba score (TS) with Strain Elastography (SE), Emax, Emean, Emin and Eratio with 2D-shear wave elastography (2D-SWE). Core biopsy for all BI-RADS 4-5 FBLs and 24-month follow-up for all BI-RADS 2-3 FBLs were considered for standard of reference. The diagnostic performance was assessed with the area under curve (AUCs) and cut-off values were determined according to the Youden's index.

Results: A total of 139 FBLs were included with 75/139 (53.9%) benign and 64/139 (46.1%) malignant FBLs. Internal vascularization patterns (p < 0.001), penetrating vessels (p < 0.001), TS 4-5 (p < 0.001) and all 2D-SWE parameters (p < 0.001) were significantly different between benign and malignant FBLs. The BI-RADS score provided an AUC of 0.876 (95% CI 0.810-0.926) for the diagnosis of malignant FBLs. Among the 2D-SWE measurements, an excellent diagnostic performance was observed for Emax with an AUC of 0.915 (95% CI 0.856-0.956) and Emean of 0.908 (95% CI 0.847-0.951). Optimal cutoff for the diagnosis of malignant FBLs were US BI-RADS > 3, Strain Ratio > 2.52, Tsukuba Score > 3, Emax > 82.6 kPa, Emean > 66.0 kPa, Emin > 54.4 kPa and Eratio > 330.8. Multiparametric ultrasound, particularly SWE, can improve specificity in the characterization of FBLs.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of Ultrasound
Journal of Ultrasound RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING-
CiteScore
4.10
自引率
15.00%
发文量
133
期刊介绍: The Journal of Ultrasound is the official journal of the Italian Society for Ultrasound in Medicine and Biology (SIUMB). The journal publishes original contributions (research and review articles, case reports, technical reports and letters to the editor) on significant advances in clinical diagnostic, interventional and therapeutic applications, clinical techniques, the physics, engineering and technology of ultrasound in medicine and biology, and in cross-sectional diagnostic imaging. The official language of Journal of Ultrasound is English.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信