用于生物力学测试的三维打印股骨头干骺端--优化与验证。

IF 2.1 3区 医学 Q2 ORTHOPEDICS
Robert C. Weinschenk, Blaine M. Oldham, Kishore M. Nagaraja, Faiqa Alam, Richard Samade, Wei Li
{"title":"用于生物力学测试的三维打印股骨头干骺端--优化与验证。","authors":"Robert C. Weinschenk,&nbsp;Blaine M. Oldham,&nbsp;Kishore M. Nagaraja,&nbsp;Faiqa Alam,&nbsp;Richard Samade,&nbsp;Wei Li","doi":"10.1002/jor.25954","DOIUrl":null,"url":null,"abstract":"<p>Polylactic acid (PLA) models of normal human femoral diaphyses were designed using three-dimensional (3D) printing technology to create inexpensive, accessible, and reproducible specimens for flexural biomechanical studies. These models were subjected to three-point bending and their response to loading was characterized. The anisotropic mechanical behavior of the 3D-printed femurs and the influence of printing orientations, infill density, wall layers, resolution, and other printing parameters were explored to develop a design space. The objective of the design space was set to emulate the flexural biomechanical response of the normal human femur bones. Results show the 3D-printed PLA diaphyseal femurs with 5% infill density, two–four wall layers, and a resolution of 200 µm resulted in a flexural strength of 184.8 ± 8.18 MPa. Models with 20% infill density and six wall layers resulted in a flexural modulus of 18.54 ± 0.543 GPa. These results emulate the biomechanical response of the normal human femur, as determined by historical target values derived from prior cadaveric and 3D printing data. With further research, inclusive of modeling the proximal and distal femur and more comprehensive biomechanical testing, 3D-printed femurs may ultimately serve as a cheap, accessible biomechanical resource for surgeons and researchers.</p>","PeriodicalId":16650,"journal":{"name":"Journal of Orthopaedic Research®","volume":"42 12","pages":"2735-2742"},"PeriodicalIF":2.1000,"publicationDate":"2024-08-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Three-dimensional-printed femoral diaphysis for biomechanical testing—Optimization and validation\",\"authors\":\"Robert C. Weinschenk,&nbsp;Blaine M. Oldham,&nbsp;Kishore M. Nagaraja,&nbsp;Faiqa Alam,&nbsp;Richard Samade,&nbsp;Wei Li\",\"doi\":\"10.1002/jor.25954\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p>Polylactic acid (PLA) models of normal human femoral diaphyses were designed using three-dimensional (3D) printing technology to create inexpensive, accessible, and reproducible specimens for flexural biomechanical studies. These models were subjected to three-point bending and their response to loading was characterized. The anisotropic mechanical behavior of the 3D-printed femurs and the influence of printing orientations, infill density, wall layers, resolution, and other printing parameters were explored to develop a design space. The objective of the design space was set to emulate the flexural biomechanical response of the normal human femur bones. Results show the 3D-printed PLA diaphyseal femurs with 5% infill density, two–four wall layers, and a resolution of 200 µm resulted in a flexural strength of 184.8 ± 8.18 MPa. Models with 20% infill density and six wall layers resulted in a flexural modulus of 18.54 ± 0.543 GPa. These results emulate the biomechanical response of the normal human femur, as determined by historical target values derived from prior cadaveric and 3D printing data. With further research, inclusive of modeling the proximal and distal femur and more comprehensive biomechanical testing, 3D-printed femurs may ultimately serve as a cheap, accessible biomechanical resource for surgeons and researchers.</p>\",\"PeriodicalId\":16650,\"journal\":{\"name\":\"Journal of Orthopaedic Research®\",\"volume\":\"42 12\",\"pages\":\"2735-2742\"},\"PeriodicalIF\":2.1000,\"publicationDate\":\"2024-08-05\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Orthopaedic Research®\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://onlinelibrary.wiley.com/doi/10.1002/jor.25954\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"ORTHOPEDICS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Orthopaedic Research®","FirstCategoryId":"3","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/jor.25954","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
引用次数: 0

摘要

利用三维(3D)打印技术设计了正常人股骨骺板的聚乳酸(PLA)模型,为弯曲生物力学研究制作了价格低廉、易于获得且可重复的标本。对这些模型进行了三点弯曲试验,并对其加载响应进行了表征。研究人员探索了三维打印股骨的各向异性力学行为以及打印方向、填充密度、壁层、分辨率和其他打印参数的影响,从而开发出一个设计空间。设计空间的目标是模拟正常人股骨的弯曲生物力学响应。结果显示,填充密度为 5%、两层至四层壁、分辨率为 200 µm 的 3D 打印聚乳酸骺端股骨的抗弯强度为 184.8 ± 8.18 兆帕。采用 20% 填充密度和六层壁的模型得出的弯曲模量为 18.54 ± 0.543 GPa。这些结果模拟了正常人体股骨的生物力学响应,而这些响应是根据之前的尸体和 3D 打印数据得出的历史目标值确定的。随着进一步的研究(包括股骨近端和远端建模以及更全面的生物力学测试),3D 打印股骨最终可能成为外科医生和研究人员廉价、易获得的生物力学资源。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Three-dimensional-printed femoral diaphysis for biomechanical testing—Optimization and validation

Polylactic acid (PLA) models of normal human femoral diaphyses were designed using three-dimensional (3D) printing technology to create inexpensive, accessible, and reproducible specimens for flexural biomechanical studies. These models were subjected to three-point bending and their response to loading was characterized. The anisotropic mechanical behavior of the 3D-printed femurs and the influence of printing orientations, infill density, wall layers, resolution, and other printing parameters were explored to develop a design space. The objective of the design space was set to emulate the flexural biomechanical response of the normal human femur bones. Results show the 3D-printed PLA diaphyseal femurs with 5% infill density, two–four wall layers, and a resolution of 200 µm resulted in a flexural strength of 184.8 ± 8.18 MPa. Models with 20% infill density and six wall layers resulted in a flexural modulus of 18.54 ± 0.543 GPa. These results emulate the biomechanical response of the normal human femur, as determined by historical target values derived from prior cadaveric and 3D printing data. With further research, inclusive of modeling the proximal and distal femur and more comprehensive biomechanical testing, 3D-printed femurs may ultimately serve as a cheap, accessible biomechanical resource for surgeons and researchers.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of Orthopaedic Research®
Journal of Orthopaedic Research® 医学-整形外科
CiteScore
6.10
自引率
3.60%
发文量
261
审稿时长
3-6 weeks
期刊介绍: The Journal of Orthopaedic Research is the forum for the rapid publication of high quality reports of new information on the full spectrum of orthopaedic research, including life sciences, engineering, translational, and clinical studies.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信