{"title":"Kirpa Kit™ 改良型手动单腔交替微批次(mSLAMB)透析装置的体外评估。","authors":"Giovanni Ceschia, Cara L Slagle, Jolyn Morgan, Amanda Snyder, James E Rose, Ed Plute, Apaara K Chawla, Rebecca Coriolan, Danielle E Soranno, Stuart L Goldstein, Denise C Hasson","doi":"10.1007/s00467-024-06471-w","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Access to pediatric dialysis is challenged in low-resource settings due to high costs, scarcity of equipment, and the lack of qualified personnel availability. We demonstrated the manual single lumen alternating micro-batch (mSLAMB) device can remove small solutes in vitro without the need for electricity, batteries, or pumps. We developed a new version (Kirpa Kit™) to address some of the technical limitations of mSLAMB. Here, we compare the in vitro clearance performance and ease of use of the Kirpa Kit™ with that of prior mSLAMB configurations.</p><p><strong>Methods: </strong>A mixture of expired packed red blood cells, 0.9% NaCl, urea, and heparin was used to test the efficiency of two mSLAMB configurations and the Kirpa Kit™ in removing potassium and urea. Clearance was evaluated by measuring percent reduction after 25-min sessions with each device. A survey was used to evaluate the ease of use of each configuration.</p><p><strong>Results: </strong>The Kirpa Kit™ achieved a median urea reduction of 82.4% and potassium reduction of 82.1%, which were higher than those achieved with the best-performing mSLAMB configuration (urea 71.9%, potassium 75.4%). The Kirpa Kit™ was easier to use with a shorter perceived time of use than the mSLAMB.</p><p><strong>Conclusions: </strong>The Kirpa Kit™, evolution of mSLAMB, is easy to use and may have improved efficacy, making it an optimal candidate for in vivo testing.</p>","PeriodicalId":19735,"journal":{"name":"Pediatric Nephrology","volume":" ","pages":"3543-3549"},"PeriodicalIF":2.6000,"publicationDate":"2024-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11539825/pdf/","citationCount":"0","resultStr":"{\"title\":\"In vitro assessment of the Kirpa Kit™ modified manual single lumen alternating micro-batch (mSLAMB) dialysis device.\",\"authors\":\"Giovanni Ceschia, Cara L Slagle, Jolyn Morgan, Amanda Snyder, James E Rose, Ed Plute, Apaara K Chawla, Rebecca Coriolan, Danielle E Soranno, Stuart L Goldstein, Denise C Hasson\",\"doi\":\"10.1007/s00467-024-06471-w\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>Access to pediatric dialysis is challenged in low-resource settings due to high costs, scarcity of equipment, and the lack of qualified personnel availability. We demonstrated the manual single lumen alternating micro-batch (mSLAMB) device can remove small solutes in vitro without the need for electricity, batteries, or pumps. We developed a new version (Kirpa Kit™) to address some of the technical limitations of mSLAMB. Here, we compare the in vitro clearance performance and ease of use of the Kirpa Kit™ with that of prior mSLAMB configurations.</p><p><strong>Methods: </strong>A mixture of expired packed red blood cells, 0.9% NaCl, urea, and heparin was used to test the efficiency of two mSLAMB configurations and the Kirpa Kit™ in removing potassium and urea. Clearance was evaluated by measuring percent reduction after 25-min sessions with each device. A survey was used to evaluate the ease of use of each configuration.</p><p><strong>Results: </strong>The Kirpa Kit™ achieved a median urea reduction of 82.4% and potassium reduction of 82.1%, which were higher than those achieved with the best-performing mSLAMB configuration (urea 71.9%, potassium 75.4%). The Kirpa Kit™ was easier to use with a shorter perceived time of use than the mSLAMB.</p><p><strong>Conclusions: </strong>The Kirpa Kit™, evolution of mSLAMB, is easy to use and may have improved efficacy, making it an optimal candidate for in vivo testing.</p>\",\"PeriodicalId\":19735,\"journal\":{\"name\":\"Pediatric Nephrology\",\"volume\":\" \",\"pages\":\"3543-3549\"},\"PeriodicalIF\":2.6000,\"publicationDate\":\"2024-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11539825/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Pediatric Nephrology\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1007/s00467-024-06471-w\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/8/2 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q1\",\"JCRName\":\"PEDIATRICS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Pediatric Nephrology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s00467-024-06471-w","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/8/2 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"PEDIATRICS","Score":null,"Total":0}
引用次数: 0

摘要

背景:由于成本高昂、设备稀缺以及缺乏合格的可用人员,在资源匮乏的环境中,小儿透析面临挑战。我们已证明手动单腔交替微批次(mSLAMB)装置可在体外清除小溶质,无需电力、电池或泵。我们开发了一种新版本(Kirpa Kit™),以解决 mSLAMB 的一些技术限制。在此,我们将 Kirpa Kit™ 的体外清除性能和易用性与之前的 mSLAMB 配置进行了比较:方法:使用过期的包装红细胞、0.9% 氯化钠、尿素和肝素的混合物来测试两种 mSLAMB 配置和 Kirpa Kit™ 清除钾和尿素的效率。在使用每种装置 25 分钟后,通过测量减少的百分比来评估清除率。调查用于评估每种配置的易用性:结果:Kirpa Kit™ 的尿素清除率中位数为 82.4%,钾清除率中位数为 82.1%,均高于性能最佳的 mSLAMB 配置(尿素清除率为 71.9%,钾清除率为 75.4%)。与 mSLAMB 相比,Kirpa Kit™ 更易于使用,使用时间更短:结论:Kirpa Kit™ 是 mSLAMB 的进化版,使用方便,疗效可能更好,是体内测试的最佳候选产品。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

In vitro assessment of the Kirpa Kit™ modified manual single lumen alternating micro-batch (mSLAMB) dialysis device.

In vitro assessment of the Kirpa Kit™ modified manual single lumen alternating micro-batch (mSLAMB) dialysis device.

Background: Access to pediatric dialysis is challenged in low-resource settings due to high costs, scarcity of equipment, and the lack of qualified personnel availability. We demonstrated the manual single lumen alternating micro-batch (mSLAMB) device can remove small solutes in vitro without the need for electricity, batteries, or pumps. We developed a new version (Kirpa Kit™) to address some of the technical limitations of mSLAMB. Here, we compare the in vitro clearance performance and ease of use of the Kirpa Kit™ with that of prior mSLAMB configurations.

Methods: A mixture of expired packed red blood cells, 0.9% NaCl, urea, and heparin was used to test the efficiency of two mSLAMB configurations and the Kirpa Kit™ in removing potassium and urea. Clearance was evaluated by measuring percent reduction after 25-min sessions with each device. A survey was used to evaluate the ease of use of each configuration.

Results: The Kirpa Kit™ achieved a median urea reduction of 82.4% and potassium reduction of 82.1%, which were higher than those achieved with the best-performing mSLAMB configuration (urea 71.9%, potassium 75.4%). The Kirpa Kit™ was easier to use with a shorter perceived time of use than the mSLAMB.

Conclusions: The Kirpa Kit™, evolution of mSLAMB, is easy to use and may have improved efficacy, making it an optimal candidate for in vivo testing.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Pediatric Nephrology
Pediatric Nephrology 医学-泌尿学与肾脏学
CiteScore
4.70
自引率
20.00%
发文量
465
审稿时长
1 months
期刊介绍: International Pediatric Nephrology Association Pediatric Nephrology publishes original clinical research related to acute and chronic diseases that affect renal function, blood pressure, and fluid and electrolyte disorders in children. Studies may involve medical, surgical, nutritional, physiologic, biochemical, genetic, pathologic or immunologic aspects of disease, imaging techniques or consequences of acute or chronic kidney disease. There are 12 issues per year that contain Editorial Commentaries, Reviews, Educational Reviews, Original Articles, Brief Reports, Rapid Communications, Clinical Quizzes, and Letters to the Editors.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信