Sami Wirtensohn, Peng Qi, Christian David, Julia Herzen, Imke Greving, Silja Flenner
{"title":"全场透射 X 射线显微镜中的纳米级暗场成像","authors":"Sami Wirtensohn, Peng Qi, Christian David, Julia Herzen, Imke Greving, Silja Flenner","doi":"10.1364/optica.524812","DOIUrl":null,"url":null,"abstract":"The dark-field signal uncovers details beyond conventional X-ray attenuation contrast, which is especially valuable for material sciences. In particular, dark-field techniques are able to reveal structures beyond the spatial resolution of a setup. However, its implementation is limited to the micrometer regime. Therefore, we propose a technique to extend full-field transmission X-ray microscopy by the dark-field signal. The proposed method is based on a well-defined illumination of a beam-shaping condenser, which allows to block the bright field by motorized apertures in the back focal plane of the objective lens. This method offers a simple implementation and enables rapid modality changes while maintaining short scan times, making dark-field imaging widely available at the nanometer scale.","PeriodicalId":19515,"journal":{"name":"Optica","volume":"43 1","pages":""},"PeriodicalIF":8.4000,"publicationDate":"2024-05-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Nanoscale dark-field imaging in full-field transmission X-ray microscopy\",\"authors\":\"Sami Wirtensohn, Peng Qi, Christian David, Julia Herzen, Imke Greving, Silja Flenner\",\"doi\":\"10.1364/optica.524812\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The dark-field signal uncovers details beyond conventional X-ray attenuation contrast, which is especially valuable for material sciences. In particular, dark-field techniques are able to reveal structures beyond the spatial resolution of a setup. However, its implementation is limited to the micrometer regime. Therefore, we propose a technique to extend full-field transmission X-ray microscopy by the dark-field signal. The proposed method is based on a well-defined illumination of a beam-shaping condenser, which allows to block the bright field by motorized apertures in the back focal plane of the objective lens. This method offers a simple implementation and enables rapid modality changes while maintaining short scan times, making dark-field imaging widely available at the nanometer scale.\",\"PeriodicalId\":19515,\"journal\":{\"name\":\"Optica\",\"volume\":\"43 1\",\"pages\":\"\"},\"PeriodicalIF\":8.4000,\"publicationDate\":\"2024-05-14\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Optica\",\"FirstCategoryId\":\"101\",\"ListUrlMain\":\"https://doi.org/10.1364/optica.524812\",\"RegionNum\":1,\"RegionCategory\":\"物理与天体物理\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"OPTICS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Optica","FirstCategoryId":"101","ListUrlMain":"https://doi.org/10.1364/optica.524812","RegionNum":1,"RegionCategory":"物理与天体物理","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"OPTICS","Score":null,"Total":0}
引用次数: 0
摘要
暗场信号能揭示传统 X 射线衰减对比之外的细节,这对材料科学尤为重要。特别是,暗场技术能够揭示超出装置空间分辨率的结构。然而,其实施范围仅限于微米级。因此,我们提出了一种利用暗场信号扩展全场透射 X 射线显微镜的技术。所提出的方法基于光束整形聚光器的明确照明,通过物镜后焦平面上的电动光圈阻挡明场。这种方法实施简单,可在保持较短扫描时间的同时快速改变模式,从而使暗场成像技术在纳米尺度上得到广泛应用。
Nanoscale dark-field imaging in full-field transmission X-ray microscopy
The dark-field signal uncovers details beyond conventional X-ray attenuation contrast, which is especially valuable for material sciences. In particular, dark-field techniques are able to reveal structures beyond the spatial resolution of a setup. However, its implementation is limited to the micrometer regime. Therefore, we propose a technique to extend full-field transmission X-ray microscopy by the dark-field signal. The proposed method is based on a well-defined illumination of a beam-shaping condenser, which allows to block the bright field by motorized apertures in the back focal plane of the objective lens. This method offers a simple implementation and enables rapid modality changes while maintaining short scan times, making dark-field imaging widely available at the nanometer scale.
期刊介绍:
Optica is an open access, online-only journal published monthly by Optica Publishing Group. It is dedicated to the rapid dissemination of high-impact peer-reviewed research in the field of optics and photonics. The journal provides a forum for theoretical or experimental, fundamental or applied research to be swiftly accessed by the international community. Optica is abstracted and indexed in Chemical Abstracts Service, Current Contents/Physical, Chemical & Earth Sciences, and Science Citation Index Expanded.