{"title":"利用 LEAP 6000 XR 原子探针仪器中降低的探测器效率重新审视碳化物的成分准确性。","authors":"Severin Jakob, Mattias Thuvander","doi":"10.1093/mam/ozae069","DOIUrl":null,"url":null,"abstract":"<p><p>The accuracy of carbon composition measurement of carbide precipitates in steel or other alloys is limited by the evaporation characteristics of carbon and the performance of current detector systems. Carbon evaporates in a higher fraction as clustered ions leading to detector pile-up during so-called multiple hits. To achieve higher accuracy, a grid was positioned behind the local electrode, reducing the detection efficiency from 52 to 7% and thereby reducing the fraction of multi-hit events. This work confirms the preferential loss of carbon due to detector pile-up. Furthermore, we demonstrate that the newer generation of commercial atom probe instruments displays somewhat higher discrepancy of carbon composition than previous generations. The reason for this might be different laser-matter interaction leading to less metal ions in multi-hit events.</p>","PeriodicalId":18625,"journal":{"name":"Microscopy and Microanalysis","volume":null,"pages":null},"PeriodicalIF":2.9000,"publicationDate":"2024-07-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Revisiting Compositional Accuracy of Carbides Using a Decreased Detector Efficiency in a LEAP 6000 XR Atom Probe Instrument.\",\"authors\":\"Severin Jakob, Mattias Thuvander\",\"doi\":\"10.1093/mam/ozae069\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The accuracy of carbon composition measurement of carbide precipitates in steel or other alloys is limited by the evaporation characteristics of carbon and the performance of current detector systems. Carbon evaporates in a higher fraction as clustered ions leading to detector pile-up during so-called multiple hits. To achieve higher accuracy, a grid was positioned behind the local electrode, reducing the detection efficiency from 52 to 7% and thereby reducing the fraction of multi-hit events. This work confirms the preferential loss of carbon due to detector pile-up. Furthermore, we demonstrate that the newer generation of commercial atom probe instruments displays somewhat higher discrepancy of carbon composition than previous generations. The reason for this might be different laser-matter interaction leading to less metal ions in multi-hit events.</p>\",\"PeriodicalId\":18625,\"journal\":{\"name\":\"Microscopy and Microanalysis\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":2.9000,\"publicationDate\":\"2024-07-31\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Microscopy and Microanalysis\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.1093/mam/ozae069\",\"RegionNum\":4,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"MATERIALS SCIENCE, MULTIDISCIPLINARY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Microscopy and Microanalysis","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1093/mam/ozae069","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"MATERIALS SCIENCE, MULTIDISCIPLINARY","Score":null,"Total":0}
Revisiting Compositional Accuracy of Carbides Using a Decreased Detector Efficiency in a LEAP 6000 XR Atom Probe Instrument.
The accuracy of carbon composition measurement of carbide precipitates in steel or other alloys is limited by the evaporation characteristics of carbon and the performance of current detector systems. Carbon evaporates in a higher fraction as clustered ions leading to detector pile-up during so-called multiple hits. To achieve higher accuracy, a grid was positioned behind the local electrode, reducing the detection efficiency from 52 to 7% and thereby reducing the fraction of multi-hit events. This work confirms the preferential loss of carbon due to detector pile-up. Furthermore, we demonstrate that the newer generation of commercial atom probe instruments displays somewhat higher discrepancy of carbon composition than previous generations. The reason for this might be different laser-matter interaction leading to less metal ions in multi-hit events.
期刊介绍:
Microscopy and Microanalysis publishes original research papers in the fields of microscopy, imaging, and compositional analysis. This distinguished international forum is intended for microscopists in both biology and materials science. The journal provides significant articles that describe new and existing techniques and instrumentation, as well as the applications of these to the imaging and analysis of microstructure. Microscopy and Microanalysis also includes review articles, letters to the editor, and book reviews.