脉络膜黑色素瘤的剪切波弹性成像:临床和血液动力学相关性。

IF 2.1 3区 医学 Q2 OPHTHALMOLOGY
Japanese Journal of Ophthalmology Pub Date : 2024-09-01 Epub Date: 2024-08-01 DOI:10.1007/s10384-024-01086-y
Konstantinos Aa Douglas, Eleni E Drakonaki, Vivian Paraskevi Douglas, Efstathios T Detorakis
{"title":"脉络膜黑色素瘤的剪切波弹性成像:临床和血液动力学相关性。","authors":"Konstantinos Aa Douglas, Eleni E Drakonaki, Vivian Paraskevi Douglas, Efstathios T Detorakis","doi":"10.1007/s10384-024-01086-y","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>This study evaluated the role of shear wave elastography imaging (SWEΙ) in uveal melanomas and the associations between SWEI and clinical and hemodynamic findings.</p><p><strong>Study design: </strong>Prospective, clinical study METHODS: Twelve patients with uveal melanomas, scheduled to undergo Ru-106 brachytherapy, were prospectively recruited from the Department of Ophthalmology of the University Hospital of Heraklion (September-December 2022). B-mode, hemodynamic and SWEI ultrasonography examinations were performed with the HiScan (OPTIKON 2000) and the LOGIQ E9 (GE Healthcare) sonographic systems, respectively. Differences in SWEI scores (kPa) between tumor (TS) and adjacent non-affected choroid (CS), as well as between TS and orbital fat (FS) were examined. Correlations between SWEI and intra-tumoral hemodynamic parameters, including peak systolic and end diastolic velocities and resistivity index (RI) were also examined.</p><p><strong>Results: </strong>TS was significantly correlated with intra-tumoral RI (Pearson's bivariate correlation coefficient 0.681, p=0.015) and with maximal tumor height (Pearson's bivariate correlation coefficient 0.620, p=0.031). TS was significantly higher than both FS and CS scores (paired-samples t-test, p=0.003 and p=0.006, respectively).</p><p><strong>Conclusions: </strong>SWEI score is applicable as a quantitative biomechanical marker in the assessment of choroidal melanoma. Choroidal melanomas are stiffer than both adjacent choroid and orbital fat. Moreover, choroidal melanomas with higher RI as well as those with higher apical elevations display higher SWEI scores.</p>","PeriodicalId":14563,"journal":{"name":"Japanese Journal of Ophthalmology","volume":null,"pages":null},"PeriodicalIF":2.1000,"publicationDate":"2024-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Shear-wave elastographic imaging in choroidal melanomas: clinical and hemodynamic correlations.\",\"authors\":\"Konstantinos Aa Douglas, Eleni E Drakonaki, Vivian Paraskevi Douglas, Efstathios T Detorakis\",\"doi\":\"10.1007/s10384-024-01086-y\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>This study evaluated the role of shear wave elastography imaging (SWEΙ) in uveal melanomas and the associations between SWEI and clinical and hemodynamic findings.</p><p><strong>Study design: </strong>Prospective, clinical study METHODS: Twelve patients with uveal melanomas, scheduled to undergo Ru-106 brachytherapy, were prospectively recruited from the Department of Ophthalmology of the University Hospital of Heraklion (September-December 2022). B-mode, hemodynamic and SWEI ultrasonography examinations were performed with the HiScan (OPTIKON 2000) and the LOGIQ E9 (GE Healthcare) sonographic systems, respectively. Differences in SWEI scores (kPa) between tumor (TS) and adjacent non-affected choroid (CS), as well as between TS and orbital fat (FS) were examined. Correlations between SWEI and intra-tumoral hemodynamic parameters, including peak systolic and end diastolic velocities and resistivity index (RI) were also examined.</p><p><strong>Results: </strong>TS was significantly correlated with intra-tumoral RI (Pearson's bivariate correlation coefficient 0.681, p=0.015) and with maximal tumor height (Pearson's bivariate correlation coefficient 0.620, p=0.031). TS was significantly higher than both FS and CS scores (paired-samples t-test, p=0.003 and p=0.006, respectively).</p><p><strong>Conclusions: </strong>SWEI score is applicable as a quantitative biomechanical marker in the assessment of choroidal melanoma. Choroidal melanomas are stiffer than both adjacent choroid and orbital fat. Moreover, choroidal melanomas with higher RI as well as those with higher apical elevations display higher SWEI scores.</p>\",\"PeriodicalId\":14563,\"journal\":{\"name\":\"Japanese Journal of Ophthalmology\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":2.1000,\"publicationDate\":\"2024-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Japanese Journal of Ophthalmology\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1007/s10384-024-01086-y\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/8/1 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q2\",\"JCRName\":\"OPHTHALMOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Japanese Journal of Ophthalmology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s10384-024-01086-y","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/8/1 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

目的:本研究评估了剪切波弹性成像(SWEΙ)在葡萄膜黑色素瘤中的作用,以及 SWEI 与临床和血液动力学结果之间的关联:前瞻性临床研究 方法:从伊拉克利翁大学医院眼科招募了 12 名计划接受 Ru-106 近距离治疗的葡萄膜黑色素瘤患者(2022 年 9 月至 12 月)。分别使用 HiScan (OPTIKON 2000) 和 LOGIQ E9 (GE Healthcare) 超声系统进行了 B 型、血液动力学和 SWEI 超声检查。检查了肿瘤(TS)和邻近未受影响脉络膜(CS)之间以及TS和眼眶脂肪(FS)之间的SWEI评分(kPa)差异。此外,还研究了 SWEI 与瘤内血液动力学参数(包括收缩和舒张末期峰值速度和电阻率指数 (RI))之间的相关性:TS与肿瘤内RI(皮尔逊双变量相关系数0.681,P=0.015)和最大肿瘤高度(皮尔逊双变量相关系数0.620,P=0.031)明显相关。TS评分明显高于FS和CS评分(配对样本t检验,P=0.003和P=0.006):结论:SWEI评分可作为评估脉络膜黑色素瘤的定量生物力学指标。脉络膜黑色素瘤的硬度高于邻近的脉络膜和眼眶脂肪。此外,RI较高的脉络膜黑色素瘤以及顶部隆起较高的脉络膜黑色素瘤显示出较高的SWEI评分。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

Shear-wave elastographic imaging in choroidal melanomas: clinical and hemodynamic correlations.

Shear-wave elastographic imaging in choroidal melanomas: clinical and hemodynamic correlations.

Purpose: This study evaluated the role of shear wave elastography imaging (SWEΙ) in uveal melanomas and the associations between SWEI and clinical and hemodynamic findings.

Study design: Prospective, clinical study METHODS: Twelve patients with uveal melanomas, scheduled to undergo Ru-106 brachytherapy, were prospectively recruited from the Department of Ophthalmology of the University Hospital of Heraklion (September-December 2022). B-mode, hemodynamic and SWEI ultrasonography examinations were performed with the HiScan (OPTIKON 2000) and the LOGIQ E9 (GE Healthcare) sonographic systems, respectively. Differences in SWEI scores (kPa) between tumor (TS) and adjacent non-affected choroid (CS), as well as between TS and orbital fat (FS) were examined. Correlations between SWEI and intra-tumoral hemodynamic parameters, including peak systolic and end diastolic velocities and resistivity index (RI) were also examined.

Results: TS was significantly correlated with intra-tumoral RI (Pearson's bivariate correlation coefficient 0.681, p=0.015) and with maximal tumor height (Pearson's bivariate correlation coefficient 0.620, p=0.031). TS was significantly higher than both FS and CS scores (paired-samples t-test, p=0.003 and p=0.006, respectively).

Conclusions: SWEI score is applicable as a quantitative biomechanical marker in the assessment of choroidal melanoma. Choroidal melanomas are stiffer than both adjacent choroid and orbital fat. Moreover, choroidal melanomas with higher RI as well as those with higher apical elevations display higher SWEI scores.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
4.80
自引率
8.30%
发文量
65
审稿时长
6-12 weeks
期刊介绍: The Japanese Journal of Ophthalmology (JJO) was inaugurated in 1957 as a quarterly journal published in English by the Ophthalmology Department of the University of Tokyo, with the aim of disseminating the achievements of Japanese ophthalmologists worldwide. JJO remains the only Japanese ophthalmology journal published in English. In 1997, the Japanese Ophthalmological Society assumed the responsibility for publishing the Japanese Journal of Ophthalmology as its official English-language publication. Currently the journal is published bimonthly and accepts papers from authors worldwide. JJO has become an international interdisciplinary forum for the publication of basic science and clinical research papers.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信