{"title":"乳腺组织致密或不致密妇女的数字乳腺断层合成术和数字乳腺 X 线照相术的诊断准确性:系统回顾和荟萃分析。","authors":"Hao Lin, Yimeng Zhang, Lixia Wu, Ceng Li","doi":"10.17219/acem/185522","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Despite its excellent screening effectiveness and sensitivity for breast cancer (BC), digital breast tomosynthesis (DBT) is controversial due to its high radiation exposure and long reading time. This study examines the diagnostic accuracy of DBT and digital mammography (DM) for BC screening and diagnosis in women with dense or non-dense breast tissue.</p><p><strong>Material and methods: </strong>PRISMA-compliant searches were performed on Medline, Embase, PubMed, Web of Science, and the Cochrane databases for articles comparing DBT and DM for BC screening until March 2023. Meta-analysis was performed using RevMan sofware, and the Cochrane Risk of Bias Assessment Tool was employed to assess study quality.</p><p><strong>Results: </strong>This meta-analysis included 11 trials with a total of 2,124,018 individuals. Screening with DBT resulted in a greater cancer detection rate, as demonstrated by a risk ratio (RR) of 1.27 (95% confidence interval (95% CI): 1.14-1.41). Digital breast tomosynthesis also had a reduced recall rate, with a RR of 0.88 (95% CI: 0.78-0.99), higher sensitivity and specificity values (pooled sensitivity of 0.91 (95% CI: 0.59-0.99)) and pooled specificity of 0.90 (95% CI: 0.42-1.0)) than DM (pooled sensitivity of 0.86 (95% CI: 0.52-1.0) and pooled specificity of 0.81 (95% CI: 0.12-1.0)). All acquired data exhibited reliability, lack of bias and statistical significance (p < 0.05).</p><p><strong>Conclusion: </strong>Digital breast tomosynthesis is a more effective screening and diagnostic assessment tool for women with dense or non-dense breasts than DM in terms of incremental cancer detection, sensitivity and recall rate.</p>","PeriodicalId":7306,"journal":{"name":"Advances in Clinical and Experimental Medicine","volume":" ","pages":""},"PeriodicalIF":2.1000,"publicationDate":"2024-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Diagnostic accuracy of digital breast tomosynthesis and digital mammography in women with dense or non-dense breast tissue: A systematic review and meta-analysis.\",\"authors\":\"Hao Lin, Yimeng Zhang, Lixia Wu, Ceng Li\",\"doi\":\"10.17219/acem/185522\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>Despite its excellent screening effectiveness and sensitivity for breast cancer (BC), digital breast tomosynthesis (DBT) is controversial due to its high radiation exposure and long reading time. This study examines the diagnostic accuracy of DBT and digital mammography (DM) for BC screening and diagnosis in women with dense or non-dense breast tissue.</p><p><strong>Material and methods: </strong>PRISMA-compliant searches were performed on Medline, Embase, PubMed, Web of Science, and the Cochrane databases for articles comparing DBT and DM for BC screening until March 2023. Meta-analysis was performed using RevMan sofware, and the Cochrane Risk of Bias Assessment Tool was employed to assess study quality.</p><p><strong>Results: </strong>This meta-analysis included 11 trials with a total of 2,124,018 individuals. Screening with DBT resulted in a greater cancer detection rate, as demonstrated by a risk ratio (RR) of 1.27 (95% confidence interval (95% CI): 1.14-1.41). Digital breast tomosynthesis also had a reduced recall rate, with a RR of 0.88 (95% CI: 0.78-0.99), higher sensitivity and specificity values (pooled sensitivity of 0.91 (95% CI: 0.59-0.99)) and pooled specificity of 0.90 (95% CI: 0.42-1.0)) than DM (pooled sensitivity of 0.86 (95% CI: 0.52-1.0) and pooled specificity of 0.81 (95% CI: 0.12-1.0)). All acquired data exhibited reliability, lack of bias and statistical significance (p < 0.05).</p><p><strong>Conclusion: </strong>Digital breast tomosynthesis is a more effective screening and diagnostic assessment tool for women with dense or non-dense breasts than DM in terms of incremental cancer detection, sensitivity and recall rate.</p>\",\"PeriodicalId\":7306,\"journal\":{\"name\":\"Advances in Clinical and Experimental Medicine\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":2.1000,\"publicationDate\":\"2024-08-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Advances in Clinical and Experimental Medicine\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.17219/acem/185522\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"MEDICINE, RESEARCH & EXPERIMENTAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Advances in Clinical and Experimental Medicine","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.17219/acem/185522","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"MEDICINE, RESEARCH & EXPERIMENTAL","Score":null,"Total":0}
Diagnostic accuracy of digital breast tomosynthesis and digital mammography in women with dense or non-dense breast tissue: A systematic review and meta-analysis.
Background: Despite its excellent screening effectiveness and sensitivity for breast cancer (BC), digital breast tomosynthesis (DBT) is controversial due to its high radiation exposure and long reading time. This study examines the diagnostic accuracy of DBT and digital mammography (DM) for BC screening and diagnosis in women with dense or non-dense breast tissue.
Material and methods: PRISMA-compliant searches were performed on Medline, Embase, PubMed, Web of Science, and the Cochrane databases for articles comparing DBT and DM for BC screening until March 2023. Meta-analysis was performed using RevMan sofware, and the Cochrane Risk of Bias Assessment Tool was employed to assess study quality.
Results: This meta-analysis included 11 trials with a total of 2,124,018 individuals. Screening with DBT resulted in a greater cancer detection rate, as demonstrated by a risk ratio (RR) of 1.27 (95% confidence interval (95% CI): 1.14-1.41). Digital breast tomosynthesis also had a reduced recall rate, with a RR of 0.88 (95% CI: 0.78-0.99), higher sensitivity and specificity values (pooled sensitivity of 0.91 (95% CI: 0.59-0.99)) and pooled specificity of 0.90 (95% CI: 0.42-1.0)) than DM (pooled sensitivity of 0.86 (95% CI: 0.52-1.0) and pooled specificity of 0.81 (95% CI: 0.12-1.0)). All acquired data exhibited reliability, lack of bias and statistical significance (p < 0.05).
Conclusion: Digital breast tomosynthesis is a more effective screening and diagnostic assessment tool for women with dense or non-dense breasts than DM in terms of incremental cancer detection, sensitivity and recall rate.
期刊介绍:
Advances in Clinical and Experimental Medicine has been published by the Wroclaw Medical University since 1992. Establishing the medical journal was the idea of Prof. Bogumił Halawa, Chair of the Department of Cardiology, and was fully supported by the Rector of Wroclaw Medical University, Prof. Zbigniew Knapik. Prof. Halawa was also the first editor-in-chief, between 1992-1997. The journal, then entitled "Postępy Medycyny Klinicznej i Doświadczalnej", appeared quarterly.
Prof. Leszek Paradowski was editor-in-chief from 1997-1999. In 1998 he initiated alterations in the profile and cover design of the journal which were accepted by the Editorial Board. The title was changed to Advances in Clinical and Experimental Medicine. Articles in English were welcomed. A number of outstanding representatives of medical science from Poland and abroad were invited to participate in the newly established International Editorial Staff.
Prof. Antonina Harłozińska-Szmyrka was editor-in-chief in years 2000-2005, in years 2006-2007 once again prof. Leszek Paradowski and prof. Maria Podolak-Dawidziak was editor-in-chief in years 2008-2016. Since 2017 the editor-in chief is prof. Maciej Bagłaj.
Since July 2005, original papers have been published only in English. Case reports are no longer accepted. The manuscripts are reviewed by two independent reviewers and a statistical reviewer, and English texts are proofread by a native speaker.
The journal has been indexed in several databases: Scopus, Ulrich’sTM International Periodicals Directory, Index Copernicus and since 2007 in Thomson Reuters databases: Science Citation Index Expanded i Journal Citation Reports/Science Edition.
In 2010 the journal obtained Impact Factor which is now 1.179 pts. Articles published in the journal are worth 15 points among Polish journals according to the Polish Committee for Scientific Research and 169.43 points according to the Index Copernicus.
Since November 7, 2012, Advances in Clinical and Experimental Medicine has been indexed and included in National Library of Medicine’s MEDLINE database. English abstracts printed in the journal are included and searchable using PubMed http://www.ncbi.nlm.nih.gov/pubmed.