脾脏弥散核磁共振成像参数标准值的年龄和性别差异。

IF 1.3 4区 医学 Q3 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
Wei-Ling Yu, Fu-Zhai Ma, Hua Huang, Ben-Heng Xiao, Xin-Ming Li, Yì Xiáng J Wáng
{"title":"脾脏弥散核磁共振成像参数标准值的年龄和性别差异。","authors":"Wei-Ling Yu, Fu-Zhai Ma, Hua Huang, Ben-Heng Xiao, Xin-Ming Li, Yì Xiáng J Wáng","doi":"10.1055/a-2357-9741","DOIUrl":null,"url":null,"abstract":"<p><p>This study investigates age and gender differences of normative values of spleen diffusion MRI parameters.We recruited 124 volunteers with MRI conducted at 1.5T. Diffusion imaging had b-values of 0, 2, 4, 7, 10, 15, 20, 30, 46, 60, 72, 100, 150, 200, 400, 600 s/mm<sup>2</sup>. ADC, IVIM-Dslow, IVIM-PF, IVIM-Dfast, and DDVD (diffusion-derived vessel density) were computed. DDVD is the signal difference between the b=0 s/mm<sup>2</sup> image and b=2, 4 s/mm<sup>2</sup> image. Only images without apparent artifacts and with good curving fitting were included in the analysis. Finally, 34 females (age: 20-71 years) and 69 males (22-70 years) were measured with ADC; 20 females (20-71 years) and 48 males (22-67 years) were measured with IVIM; 32 females (20-71 years) and 65 males (22-70 years) were measured with DDVD parameter.An age-related decrease in ADC was noted for females, while such a trend was not noted for males. A very high level of heterogeneity was noted for the data for the males, with the highest ADC value being 1.710 × 10<sup>-3</sup>mm <sup>2</sup>/s and the lowest ADC value being 0.705 × 10<sup>-3</sup> mm<sup>2</sup>/s when b=0 and 600 s/mm <sup>2</sup> were used for ADC calculation. A male-female data comparison did not show a statistically significant difference between the ADC median value. However, ADCs > 1.3 × 10<sup>-3</sup> mm<sup>2</sup>/s were only seen among males. A very high level of heterogeneity was also noted for males' Dslow, with the highest value being 1.468 × 10<sup>-3</sup> mm<sup>2</sup>/s and the lowest value being 0.600 × 10<sup>-3</sup> mm<sup>2</sup>/s. Both PF and Dfast demonstrated a trend of age-related increase for older subjects. PF values were higher among males than females. However, no difference was noted for Dfast between males and females. DDVD did not show an age-related trend both for females and males. No difference was noted in DDVD values between males and females.Interpreting normal spleen diffusion MRI parameters should consider age and gender factors. · An age-related decrease in spleen ADC and IVIM-Dslow was seen for healthy females.. · There is a high level of heterogeneity for spleen ADC and IVIM-Dslow data for healthy males.. · IVIM modelled perfusion fraction and Dfast demonstrate an artificial trend of age-related increase for older subjects.. · Vessel density measured on diffusion imaging does not show an age-related trend.. · Yu W, Ma FZ, Huang H et al. Age and gender differences of normative values of spleen diffusion MRI parameters. Rofo 2025; 197: 535-545.</p>","PeriodicalId":21490,"journal":{"name":"Rofo-fortschritte Auf Dem Gebiet Der Rontgenstrahlen Und Der Bildgebenden Verfahren","volume":" ","pages":"535-545"},"PeriodicalIF":1.3000,"publicationDate":"2025-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Age and gender differences of normative values of spleen diffusion MRI parameters.\",\"authors\":\"Wei-Ling Yu, Fu-Zhai Ma, Hua Huang, Ben-Heng Xiao, Xin-Ming Li, Yì Xiáng J Wáng\",\"doi\":\"10.1055/a-2357-9741\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>This study investigates age and gender differences of normative values of spleen diffusion MRI parameters.We recruited 124 volunteers with MRI conducted at 1.5T. Diffusion imaging had b-values of 0, 2, 4, 7, 10, 15, 20, 30, 46, 60, 72, 100, 150, 200, 400, 600 s/mm<sup>2</sup>. ADC, IVIM-Dslow, IVIM-PF, IVIM-Dfast, and DDVD (diffusion-derived vessel density) were computed. DDVD is the signal difference between the b=0 s/mm<sup>2</sup> image and b=2, 4 s/mm<sup>2</sup> image. Only images without apparent artifacts and with good curving fitting were included in the analysis. Finally, 34 females (age: 20-71 years) and 69 males (22-70 years) were measured with ADC; 20 females (20-71 years) and 48 males (22-67 years) were measured with IVIM; 32 females (20-71 years) and 65 males (22-70 years) were measured with DDVD parameter.An age-related decrease in ADC was noted for females, while such a trend was not noted for males. A very high level of heterogeneity was noted for the data for the males, with the highest ADC value being 1.710 × 10<sup>-3</sup>mm <sup>2</sup>/s and the lowest ADC value being 0.705 × 10<sup>-3</sup> mm<sup>2</sup>/s when b=0 and 600 s/mm <sup>2</sup> were used for ADC calculation. A male-female data comparison did not show a statistically significant difference between the ADC median value. However, ADCs > 1.3 × 10<sup>-3</sup> mm<sup>2</sup>/s were only seen among males. A very high level of heterogeneity was also noted for males' Dslow, with the highest value being 1.468 × 10<sup>-3</sup> mm<sup>2</sup>/s and the lowest value being 0.600 × 10<sup>-3</sup> mm<sup>2</sup>/s. Both PF and Dfast demonstrated a trend of age-related increase for older subjects. PF values were higher among males than females. However, no difference was noted for Dfast between males and females. DDVD did not show an age-related trend both for females and males. No difference was noted in DDVD values between males and females.Interpreting normal spleen diffusion MRI parameters should consider age and gender factors. · An age-related decrease in spleen ADC and IVIM-Dslow was seen for healthy females.. · There is a high level of heterogeneity for spleen ADC and IVIM-Dslow data for healthy males.. · IVIM modelled perfusion fraction and Dfast demonstrate an artificial trend of age-related increase for older subjects.. · Vessel density measured on diffusion imaging does not show an age-related trend.. · Yu W, Ma FZ, Huang H et al. Age and gender differences of normative values of spleen diffusion MRI parameters. Rofo 2025; 197: 535-545.</p>\",\"PeriodicalId\":21490,\"journal\":{\"name\":\"Rofo-fortschritte Auf Dem Gebiet Der Rontgenstrahlen Und Der Bildgebenden Verfahren\",\"volume\":\" \",\"pages\":\"535-545\"},\"PeriodicalIF\":1.3000,\"publicationDate\":\"2025-05-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Rofo-fortschritte Auf Dem Gebiet Der Rontgenstrahlen Und Der Bildgebenden Verfahren\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1055/a-2357-9741\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/7/30 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q3\",\"JCRName\":\"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Rofo-fortschritte Auf Dem Gebiet Der Rontgenstrahlen Und Der Bildgebenden Verfahren","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1055/a-2357-9741","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/7/30 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

摘要

本研究调查了脾脏弥散核磁共振成像参数正常值的年龄和性别差异。我们招募了 124 名志愿者,在 1.5T 下进行了核磁共振成像。弥散成像的 b 值为 0、2、4、7、10、15、20、30、46、60、72、100、150、200、400、600 s/mm2。计算 ADC、IVIM-Dslow、IVIM-PF、IVIM-Dfast 和 DDVD(扩散衍生血管密度)。DDVD 是 b=0 s/mm2 图像与 b=2, 4 s/mm2 图像之间的信号差。只有无明显伪影且曲线拟合良好的图像才被纳入分析。最后,对 34 名女性(年龄:20-71 岁)和 69 名男性(22-70 岁)进行了 ADC 测量;对 20 名女性(20-71 岁)和 48 名男性(22-67 岁)进行了 IVIM 测量;对 32 名女性(20-71 岁)和 65 名男性(22-70 岁)进行了 DDVD 参数测量。男性数据的异质性非常高,当使用 b=0 和 600 s/mm 2 计算 ADC 时,最高 ADC 值为 1.710 × 10-3 mm 2/s,最低 ADC 值为 0.705 × 10-3 mm2/s。男女数据对比并未显示 ADC 中位值之间存在显著的统计学差异。然而,只有男性的 ADC 值大于 1.3 × 10-3 mm2/s。男性的 Dslow 也存在很高的异质性,最高值为 1.468 × 10-3 mm2/s,最低值为 0.600 × 10-3 mm2/s。在年龄较大的受试者中,PF 和 Dfast 都呈现出与年龄相关的增长趋势。男性的 PF 值高于女性。不过,男性和女性的 Dfast 值没有差异。女性和男性的 DDVD 均未显示出与年龄相关的趋势。解读正常脾脏弥散 MRI 参数应考虑年龄和性别因素。- 健康女性脾脏 ADC 和 IVIM-Dslow 的下降与年龄有关。- 健康男性的脾脏ADC和IVIM-Dslow数据存在高度异质性。- IVIM建模的灌注分数和Dfast显示出老年受试者与年龄相关的人为增加趋势- 弥散成像测量的血管密度未显示出与年龄相关的趋势- Yu W, Ma FZ, Huang H et al.Fortschr Röntgenstr 2024; DOI 10.1055/a-2357-9741.
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Age and gender differences of normative values of spleen diffusion MRI parameters.

This study investigates age and gender differences of normative values of spleen diffusion MRI parameters.We recruited 124 volunteers with MRI conducted at 1.5T. Diffusion imaging had b-values of 0, 2, 4, 7, 10, 15, 20, 30, 46, 60, 72, 100, 150, 200, 400, 600 s/mm2. ADC, IVIM-Dslow, IVIM-PF, IVIM-Dfast, and DDVD (diffusion-derived vessel density) were computed. DDVD is the signal difference between the b=0 s/mm2 image and b=2, 4 s/mm2 image. Only images without apparent artifacts and with good curving fitting were included in the analysis. Finally, 34 females (age: 20-71 years) and 69 males (22-70 years) were measured with ADC; 20 females (20-71 years) and 48 males (22-67 years) were measured with IVIM; 32 females (20-71 years) and 65 males (22-70 years) were measured with DDVD parameter.An age-related decrease in ADC was noted for females, while such a trend was not noted for males. A very high level of heterogeneity was noted for the data for the males, with the highest ADC value being 1.710 × 10-3mm 2/s and the lowest ADC value being 0.705 × 10-3 mm2/s when b=0 and 600 s/mm 2 were used for ADC calculation. A male-female data comparison did not show a statistically significant difference between the ADC median value. However, ADCs > 1.3 × 10-3 mm2/s were only seen among males. A very high level of heterogeneity was also noted for males' Dslow, with the highest value being 1.468 × 10-3 mm2/s and the lowest value being 0.600 × 10-3 mm2/s. Both PF and Dfast demonstrated a trend of age-related increase for older subjects. PF values were higher among males than females. However, no difference was noted for Dfast between males and females. DDVD did not show an age-related trend both for females and males. No difference was noted in DDVD values between males and females.Interpreting normal spleen diffusion MRI parameters should consider age and gender factors. · An age-related decrease in spleen ADC and IVIM-Dslow was seen for healthy females.. · There is a high level of heterogeneity for spleen ADC and IVIM-Dslow data for healthy males.. · IVIM modelled perfusion fraction and Dfast demonstrate an artificial trend of age-related increase for older subjects.. · Vessel density measured on diffusion imaging does not show an age-related trend.. · Yu W, Ma FZ, Huang H et al. Age and gender differences of normative values of spleen diffusion MRI parameters. Rofo 2025; 197: 535-545.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
1.20
自引率
5.60%
发文量
340
期刊介绍: Die RöFo veröffentlicht Originalarbeiten, Übersichtsartikel und Fallberichte aus dem Bereich der Radiologie und den weiteren bildgebenden Verfahren in der Medizin. Es dürfen nur Arbeiten eingereicht werden, die noch nicht veröffentlicht sind und die auch nicht gleichzeitig einer anderen Zeitschrift zur Veröffentlichung angeboten wurden. Alle eingereichten Beiträge unterliegen einer sorgfältigen fachlichen Begutachtung. Gegründet 1896 – nur knapp 1 Jahr nach der Entdeckung der Röntgenstrahlen durch C.W. Röntgen – blickt die RöFo auf über 100 Jahre Erfahrung als wichtigstes Publikationsmedium in der deutschsprachigen Radiologie zurück. Sie ist damit die älteste radiologische Fachzeitschrift und schafft es erfolgreich, lange Kontinuität mit dem Anspruch an wissenschaftliches Publizieren auf internationalem Niveau zu verbinden. Durch ihren zentralen Platz im Verlagsprogramm stellte die RöFo die Basis für das heute umfassende und erfolgreiche Radiologie-Medienangebot im Georg Thieme Verlag. Besonders eng verbunden ist die RöFo mit der Geschichte der Röntgengesellschaften in Deutschland und Österreich. Sie ist offizielles Organ von DRG und ÖRG und die Mitglieder der Fachgesellschaften erhalten die Zeitschrift im Rahmen ihrer Mitgliedschaft. Mit ihrem wissenschaftlichen Kernteil und dem eigenen Mitteilungsteil der Fachgesellschaften bietet die RöFo Monat für Monat ein Forum für den Austausch von Inhalten und Botschaften der radiologischen Community im deutschsprachigen Raum.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信