{"title":"温度范围为 15-300 K 的磁制冷器低温机械热敏开关参数","authors":"K.A. Kolesov , A.S. Skorniakov , V.V. Koledov , V.G. Shavrov , A.M. Aliev , A.G. Gamzatov , L.N. Khanov , A.V. Mashirov","doi":"10.1016/j.cryogenics.2024.103899","DOIUrl":null,"url":null,"abstract":"<div><p>The main aim of this work is to study heat transfer in mechanical thermal switch under conditions close to a real magnetic refrigeration. This study examines the thermal behavior of a mechanical thermal switch which comprise a detachable pair of copper–copper contact bulks, incorporating an indium foil thermal interface with a 100 µm thickness. We investigated the time it took to reach thermal equilibrium from initial temperature span of 3 K, 5 K, and 10 K and explored the influence of the indium foil thermal interface within a temperature range of 15 to 300 K. The experimental data provided the heat dissipation values required to maintain the specified temperature of the object being cooled. As the results showed, the use an indium thermal interface significantly reduces the time until thermal equilibrium occurs.</p></div>","PeriodicalId":10812,"journal":{"name":"Cryogenics","volume":null,"pages":null},"PeriodicalIF":1.8000,"publicationDate":"2024-07-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Parameters of the cryogenic mechanical thermal switch with temperature range 15–300 K for magnetic refrigerators\",\"authors\":\"K.A. Kolesov , A.S. Skorniakov , V.V. Koledov , V.G. Shavrov , A.M. Aliev , A.G. Gamzatov , L.N. Khanov , A.V. Mashirov\",\"doi\":\"10.1016/j.cryogenics.2024.103899\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>The main aim of this work is to study heat transfer in mechanical thermal switch under conditions close to a real magnetic refrigeration. This study examines the thermal behavior of a mechanical thermal switch which comprise a detachable pair of copper–copper contact bulks, incorporating an indium foil thermal interface with a 100 µm thickness. We investigated the time it took to reach thermal equilibrium from initial temperature span of 3 K, 5 K, and 10 K and explored the influence of the indium foil thermal interface within a temperature range of 15 to 300 K. The experimental data provided the heat dissipation values required to maintain the specified temperature of the object being cooled. As the results showed, the use an indium thermal interface significantly reduces the time until thermal equilibrium occurs.</p></div>\",\"PeriodicalId\":10812,\"journal\":{\"name\":\"Cryogenics\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.8000,\"publicationDate\":\"2024-07-18\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Cryogenics\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S001122752400119X\",\"RegionNum\":3,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"PHYSICS, APPLIED\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Cryogenics","FirstCategoryId":"5","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S001122752400119X","RegionNum":3,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"PHYSICS, APPLIED","Score":null,"Total":0}
引用次数: 0
摘要
这项工作的主要目的是研究机械热敏开关在接近实际磁制冷条件下的热传导。本研究考察了机械热敏开关的热行为,该开关由一对可拆卸的铜-铜接触块组成,并结合了厚度为 100 µm 的铟箔热界面。我们研究了从 3 K、5 K 和 10 K 的初始温度跨度达到热平衡所需的时间,并探讨了铟箔热界面在 15 至 300 K 温度范围内的影响。结果表明,铟热界面的使用大大缩短了达到热平衡的时间。
Parameters of the cryogenic mechanical thermal switch with temperature range 15–300 K for magnetic refrigerators
The main aim of this work is to study heat transfer in mechanical thermal switch under conditions close to a real magnetic refrigeration. This study examines the thermal behavior of a mechanical thermal switch which comprise a detachable pair of copper–copper contact bulks, incorporating an indium foil thermal interface with a 100 µm thickness. We investigated the time it took to reach thermal equilibrium from initial temperature span of 3 K, 5 K, and 10 K and explored the influence of the indium foil thermal interface within a temperature range of 15 to 300 K. The experimental data provided the heat dissipation values required to maintain the specified temperature of the object being cooled. As the results showed, the use an indium thermal interface significantly reduces the time until thermal equilibrium occurs.
期刊介绍:
Cryogenics is the world''s leading journal focusing on all aspects of cryoengineering and cryogenics. Papers published in Cryogenics cover a wide variety of subjects in low temperature engineering and research. Among the areas covered are:
- Applications of superconductivity: magnets, electronics, devices
- Superconductors and their properties
- Properties of materials: metals, alloys, composites, polymers, insulations
- New applications of cryogenic technology to processes, devices, machinery
- Refrigeration and liquefaction technology
- Thermodynamics
- Fluid properties and fluid mechanics
- Heat transfer
- Thermometry and measurement science
- Cryogenics in medicine
- Cryoelectronics