{"title":"硼中子俘获疗法加速器中子源场外剂量研究","authors":"","doi":"10.1016/j.apradiso.2024.111458","DOIUrl":null,"url":null,"abstract":"<div><p>One important issue in Boron Neutron Capture Therapy is the delivered dose to the tissues outside the tumor. An international standard for light ion beam systems sets two recommended limits for out-of-field dose based on distance from the field edge: maximum absorbed dose from all radiation types shall not exceed 0.5 % of the maximum dose at distances 15 cm to 50 cm from the field edge. At distances <span><math><mrow><mo>></mo><mn>50</mn></mrow></math></span> cm from the field edge, the maximum absorbed dose shall not exceed 0.1 %. This paper is a continuation of our previous works focused on the design of an accelerator-based neutron source for BNCT. We already designed a novel Beam Shape Assembly which meets the IAEA criteria for BNCT treatments. Using this BSA, in the present work, we characterize by Monte Carlo simulations the dose outside the neutron field. The out-of-field dose has been assessed via estimates using the ambient and equivalent dose. Also the boron uptake in healthy tissues has been analyzed for the equivalent dose computation. It is concluded that our design for a future accelerator-based source for BNCT meets reasonably well the criteria defined from other forms of radiotherapy on both equivalent and effective dose outside the field.</p></div>","PeriodicalId":8096,"journal":{"name":"Applied Radiation and Isotopes","volume":null,"pages":null},"PeriodicalIF":1.6000,"publicationDate":"2024-07-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.sciencedirect.com/science/article/pii/S0969804324002860/pdfft?md5=dcb830510f2322299adfbe4d4ba46a0b&pid=1-s2.0-S0969804324002860-main.pdf","citationCount":"0","resultStr":"{\"title\":\"Study of the out-of-field dose from an accelerator-based neutron source for boron neutron capture therapy\",\"authors\":\"\",\"doi\":\"10.1016/j.apradiso.2024.111458\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>One important issue in Boron Neutron Capture Therapy is the delivered dose to the tissues outside the tumor. An international standard for light ion beam systems sets two recommended limits for out-of-field dose based on distance from the field edge: maximum absorbed dose from all radiation types shall not exceed 0.5 % of the maximum dose at distances 15 cm to 50 cm from the field edge. At distances <span><math><mrow><mo>></mo><mn>50</mn></mrow></math></span> cm from the field edge, the maximum absorbed dose shall not exceed 0.1 %. This paper is a continuation of our previous works focused on the design of an accelerator-based neutron source for BNCT. We already designed a novel Beam Shape Assembly which meets the IAEA criteria for BNCT treatments. Using this BSA, in the present work, we characterize by Monte Carlo simulations the dose outside the neutron field. The out-of-field dose has been assessed via estimates using the ambient and equivalent dose. Also the boron uptake in healthy tissues has been analyzed for the equivalent dose computation. It is concluded that our design for a future accelerator-based source for BNCT meets reasonably well the criteria defined from other forms of radiotherapy on both equivalent and effective dose outside the field.</p></div>\",\"PeriodicalId\":8096,\"journal\":{\"name\":\"Applied Radiation and Isotopes\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.6000,\"publicationDate\":\"2024-07-27\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.sciencedirect.com/science/article/pii/S0969804324002860/pdfft?md5=dcb830510f2322299adfbe4d4ba46a0b&pid=1-s2.0-S0969804324002860-main.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Applied Radiation and Isotopes\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S0969804324002860\",\"RegionNum\":3,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"CHEMISTRY, INORGANIC & NUCLEAR\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Applied Radiation and Isotopes","FirstCategoryId":"5","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0969804324002860","RegionNum":3,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"CHEMISTRY, INORGANIC & NUCLEAR","Score":null,"Total":0}
Study of the out-of-field dose from an accelerator-based neutron source for boron neutron capture therapy
One important issue in Boron Neutron Capture Therapy is the delivered dose to the tissues outside the tumor. An international standard for light ion beam systems sets two recommended limits for out-of-field dose based on distance from the field edge: maximum absorbed dose from all radiation types shall not exceed 0.5 % of the maximum dose at distances 15 cm to 50 cm from the field edge. At distances cm from the field edge, the maximum absorbed dose shall not exceed 0.1 %. This paper is a continuation of our previous works focused on the design of an accelerator-based neutron source for BNCT. We already designed a novel Beam Shape Assembly which meets the IAEA criteria for BNCT treatments. Using this BSA, in the present work, we characterize by Monte Carlo simulations the dose outside the neutron field. The out-of-field dose has been assessed via estimates using the ambient and equivalent dose. Also the boron uptake in healthy tissues has been analyzed for the equivalent dose computation. It is concluded that our design for a future accelerator-based source for BNCT meets reasonably well the criteria defined from other forms of radiotherapy on both equivalent and effective dose outside the field.
期刊介绍:
Applied Radiation and Isotopes provides a high quality medium for the publication of substantial, original and scientific and technological papers on the development and peaceful application of nuclear, radiation and radionuclide techniques in chemistry, physics, biochemistry, biology, medicine, security, engineering and in the earth, planetary and environmental sciences, all including dosimetry. Nuclear techniques are defined in the broadest sense and both experimental and theoretical papers are welcome. They include the development and use of α- and β-particles, X-rays and γ-rays, neutrons and other nuclear particles and radiations from all sources, including radionuclides, synchrotron sources, cyclotrons and reactors and from the natural environment.
The journal aims to publish papers with significance to an international audience, containing substantial novelty and scientific impact. The Editors reserve the rights to reject, with or without external review, papers that do not meet these criteria.
Papers dealing with radiation processing, i.e., where radiation is used to bring about a biological, chemical or physical change in a material, should be directed to our sister journal Radiation Physics and Chemistry.