{"title":"基于自适应控制方案的分源逆变器并联有源电力滤波器改善电能质量","authors":"Prasanta Kumar Barik,&nbsp;Sarita Samal,&nbsp;Deepak Kumar Gupta,&nbsp;Bhargav Appasani,&nbsp;Amitkumar V. Jha,&nbsp;Md. Minarul Islam,&nbsp;Taha Selim Ustun","doi":"10.1049/pel2.12746","DOIUrl":null,"url":null,"abstract":"<p>Although single-stage inverters are popular for simpler design they face difficulties in shoot-through mode operation. Insufficient DC voltage regulation and complicated LC network are principal drawbacks of these topologies. A new split source inverter (SSI) can solve problems with single-stage inverters. In this paper, SSI replaced the voltage source inverter (VSI) of a shunt active power filter (SAPF) which alleviates power quality (PQ) issues in power system. Furthermore, a VSI-based SAPF faces challenges to maintain consistent voltage across DC-link capacitor, exactly compensating current generation, and switching loss reduction in inverter. This study examined efficacy of two inverter-based SAPFs considering a modified synchronous reference frame approach for generating reference current; fuzzy logic controller for regulating DC-link voltage; and adaptive fuzzy hysteresis current controller for generating switching pulses. Ideal and non-ideal sources were considered when running the simulations for various load circumstances. The proposed SSI-based SAPF with an advanced control approach can eradicate source current harmonics to 0.52% and 0.45% under ideal source conditions, and 0.65% and 0.54% under non-ideal source conditions for non-linear loads. Similarly, the ripples in the DC-link voltage are also reduced to 2–3 V for the ideal case and 4–5 V for non-ideal case.</p>","PeriodicalId":1,"journal":{"name":"Accounts of Chemical Research","volume":null,"pages":null},"PeriodicalIF":16.4000,"publicationDate":"2024-07-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://onlinelibrary.wiley.com/doi/epdf/10.1049/pel2.12746","citationCount":"0","resultStr":"{\"title\":\"Split-source inverter with adaptive control scheme-based shunt active power filter for power quality improvement\",\"authors\":\"Prasanta Kumar Barik,&nbsp;Sarita Samal,&nbsp;Deepak Kumar Gupta,&nbsp;Bhargav Appasani,&nbsp;Amitkumar V. Jha,&nbsp;Md. Minarul Islam,&nbsp;Taha Selim Ustun\",\"doi\":\"10.1049/pel2.12746\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p>Although single-stage inverters are popular for simpler design they face difficulties in shoot-through mode operation. Insufficient DC voltage regulation and complicated LC network are principal drawbacks of these topologies. A new split source inverter (SSI) can solve problems with single-stage inverters. In this paper, SSI replaced the voltage source inverter (VSI) of a shunt active power filter (SAPF) which alleviates power quality (PQ) issues in power system. Furthermore, a VSI-based SAPF faces challenges to maintain consistent voltage across DC-link capacitor, exactly compensating current generation, and switching loss reduction in inverter. This study examined efficacy of two inverter-based SAPFs considering a modified synchronous reference frame approach for generating reference current; fuzzy logic controller for regulating DC-link voltage; and adaptive fuzzy hysteresis current controller for generating switching pulses. Ideal and non-ideal sources were considered when running the simulations for various load circumstances. The proposed SSI-based SAPF with an advanced control approach can eradicate source current harmonics to 0.52% and 0.45% under ideal source conditions, and 0.65% and 0.54% under non-ideal source conditions for non-linear loads. Similarly, the ripples in the DC-link voltage are also reduced to 2–3 V for the ideal case and 4–5 V for non-ideal case.</p>\",\"PeriodicalId\":1,\"journal\":{\"name\":\"Accounts of Chemical Research\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":16.4000,\"publicationDate\":\"2024-07-17\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://onlinelibrary.wiley.com/doi/epdf/10.1049/pel2.12746\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Accounts of Chemical Research\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://onlinelibrary.wiley.com/doi/10.1049/pel2.12746\",\"RegionNum\":1,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"CHEMISTRY, MULTIDISCIPLINARY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Accounts of Chemical Research","FirstCategoryId":"5","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1049/pel2.12746","RegionNum":1,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 0

摘要

虽然单级逆变器因设计简单而广受欢迎,但在直通模式运行时却面临着困难。直流电压调节不足和复杂的 LC 网络是这些拓扑结构的主要缺点。新型分离源逆变器(SSI)可以解决单级逆变器的问题。在本文中,SSI 取代了并联有源电力滤波器(SAPF)中的电压源逆变器(VSI),从而缓解了电力系统中的电能质量(PQ)问题。此外,基于 VSI 的 SAPF 还面临着保持直流链路电容器电压一致、精确补偿电流产生和降低逆变器开关损耗等挑战。本研究考察了两种基于逆变器的 SAPF 的功效,考虑到了用于产生参考电流的修改同步参考帧方法、用于调节直流链路电压的模糊逻辑控制器以及用于产生开关脉冲的自适应模糊滞后电流控制器。在对各种负载情况进行仿真时,考虑了理想和非理想源。所提出的基于 SSI 的 SAPF 采用先进的控制方法,在理想源条件下可消除 0.52% 和 0.45% 的源电流谐波,在非线性负载的非理想源条件下可消除 0.65% 和 0.54% 的源电流谐波。同样,直流链路电压的纹波在理想情况下也降至 2-3 V,在非理想情况下降至 4-5 V。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

Split-source inverter with adaptive control scheme-based shunt active power filter for power quality improvement

Split-source inverter with adaptive control scheme-based shunt active power filter for power quality improvement

Although single-stage inverters are popular for simpler design they face difficulties in shoot-through mode operation. Insufficient DC voltage regulation and complicated LC network are principal drawbacks of these topologies. A new split source inverter (SSI) can solve problems with single-stage inverters. In this paper, SSI replaced the voltage source inverter (VSI) of a shunt active power filter (SAPF) which alleviates power quality (PQ) issues in power system. Furthermore, a VSI-based SAPF faces challenges to maintain consistent voltage across DC-link capacitor, exactly compensating current generation, and switching loss reduction in inverter. This study examined efficacy of two inverter-based SAPFs considering a modified synchronous reference frame approach for generating reference current; fuzzy logic controller for regulating DC-link voltage; and adaptive fuzzy hysteresis current controller for generating switching pulses. Ideal and non-ideal sources were considered when running the simulations for various load circumstances. The proposed SSI-based SAPF with an advanced control approach can eradicate source current harmonics to 0.52% and 0.45% under ideal source conditions, and 0.65% and 0.54% under non-ideal source conditions for non-linear loads. Similarly, the ripples in the DC-link voltage are also reduced to 2–3 V for the ideal case and 4–5 V for non-ideal case.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Accounts of Chemical Research
Accounts of Chemical Research 化学-化学综合
CiteScore
31.40
自引率
1.10%
发文量
312
审稿时长
2 months
期刊介绍: Accounts of Chemical Research presents short, concise and critical articles offering easy-to-read overviews of basic research and applications in all areas of chemistry and biochemistry. These short reviews focus on research from the author’s own laboratory and are designed to teach the reader about a research project. In addition, Accounts of Chemical Research publishes commentaries that give an informed opinion on a current research problem. Special Issues online are devoted to a single topic of unusual activity and significance. Accounts of Chemical Research replaces the traditional article abstract with an article "Conspectus." These entries synopsize the research affording the reader a closer look at the content and significance of an article. Through this provision of a more detailed description of the article contents, the Conspectus enhances the article's discoverability by search engines and the exposure for the research.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信