Chenhao Zhang, Yang Li, Wei Han, Guobing Song, Hua Zhang
{"title":"基于设备非线性和时变特性的时域谐波源定位和评估方法","authors":"Chenhao Zhang, Yang Li, Wei Han, Guobing Song, Hua Zhang","doi":"10.1049/gtd2.13219","DOIUrl":null,"url":null,"abstract":"<p>Most of the existing methods for harmonic analysis are from frequency-domain perspective. In fact, the essential factor for generating harmonics is non-linear characteristic or time-varying property. Therefore, the harmonic generation mechanism and the harmonic source location method are investigated from the time domain perspective in this paper. Firstly, a general model of non-harmonic sources is established. The non-harmonic sources will match well with the proposed general model while the harmonic source will not. Then correlation coefficient that reflects compliance degree between each device and the general model is defined for distinguishing harmonic sources from non-harmonic sources. On this basis, a novel time-domain harmonic source location method is proposed. Numerous simulations and experiments have demonstrated that the proposed method has good performance under fluctuations, saturations, pre-distortions, transient process, and resonances. The defined correlation coefficient can reflect non-linearity/time-varying degree of the harmonic source, which can be used for evaluating harmonic emission level of each harmonic source. On this basis, a simple harmonic responsibility division method is proposed, which is immune to possible fluctuations, pre-distortions, saturations, resonances, and impedance variation.</p>","PeriodicalId":13261,"journal":{"name":"Iet Generation Transmission & Distribution","volume":null,"pages":null},"PeriodicalIF":2.0000,"publicationDate":"2024-07-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://onlinelibrary.wiley.com/doi/epdf/10.1049/gtd2.13219","citationCount":"0","resultStr":"{\"title\":\"Time-domain harmonic source location and evaluation methods based on non-linear and time-varying properties of devices\",\"authors\":\"Chenhao Zhang, Yang Li, Wei Han, Guobing Song, Hua Zhang\",\"doi\":\"10.1049/gtd2.13219\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p>Most of the existing methods for harmonic analysis are from frequency-domain perspective. In fact, the essential factor for generating harmonics is non-linear characteristic or time-varying property. Therefore, the harmonic generation mechanism and the harmonic source location method are investigated from the time domain perspective in this paper. Firstly, a general model of non-harmonic sources is established. The non-harmonic sources will match well with the proposed general model while the harmonic source will not. Then correlation coefficient that reflects compliance degree between each device and the general model is defined for distinguishing harmonic sources from non-harmonic sources. On this basis, a novel time-domain harmonic source location method is proposed. Numerous simulations and experiments have demonstrated that the proposed method has good performance under fluctuations, saturations, pre-distortions, transient process, and resonances. The defined correlation coefficient can reflect non-linearity/time-varying degree of the harmonic source, which can be used for evaluating harmonic emission level of each harmonic source. On this basis, a simple harmonic responsibility division method is proposed, which is immune to possible fluctuations, pre-distortions, saturations, resonances, and impedance variation.</p>\",\"PeriodicalId\":13261,\"journal\":{\"name\":\"Iet Generation Transmission & Distribution\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":2.0000,\"publicationDate\":\"2024-07-23\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://onlinelibrary.wiley.com/doi/epdf/10.1049/gtd2.13219\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Iet Generation Transmission & Distribution\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://onlinelibrary.wiley.com/doi/10.1049/gtd2.13219\",\"RegionNum\":4,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"ENGINEERING, ELECTRICAL & ELECTRONIC\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Iet Generation Transmission & Distribution","FirstCategoryId":"5","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1049/gtd2.13219","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
Time-domain harmonic source location and evaluation methods based on non-linear and time-varying properties of devices
Most of the existing methods for harmonic analysis are from frequency-domain perspective. In fact, the essential factor for generating harmonics is non-linear characteristic or time-varying property. Therefore, the harmonic generation mechanism and the harmonic source location method are investigated from the time domain perspective in this paper. Firstly, a general model of non-harmonic sources is established. The non-harmonic sources will match well with the proposed general model while the harmonic source will not. Then correlation coefficient that reflects compliance degree between each device and the general model is defined for distinguishing harmonic sources from non-harmonic sources. On this basis, a novel time-domain harmonic source location method is proposed. Numerous simulations and experiments have demonstrated that the proposed method has good performance under fluctuations, saturations, pre-distortions, transient process, and resonances. The defined correlation coefficient can reflect non-linearity/time-varying degree of the harmonic source, which can be used for evaluating harmonic emission level of each harmonic source. On this basis, a simple harmonic responsibility division method is proposed, which is immune to possible fluctuations, pre-distortions, saturations, resonances, and impedance variation.
期刊介绍:
IET Generation, Transmission & Distribution is intended as a forum for the publication and discussion of current practice and future developments in electric power generation, transmission and distribution. Practical papers in which examples of good present practice can be described and disseminated are particularly sought. Papers of high technical merit relying on mathematical arguments and computation will be considered, but authors are asked to relegate, as far as possible, the details of analysis to an appendix.
The scope of IET Generation, Transmission & Distribution includes the following:
Design of transmission and distribution systems
Operation and control of power generation
Power system management, planning and economics
Power system operation, protection and control
Power system measurement and modelling
Computer applications and computational intelligence in power flexible AC or DC transmission systems
Special Issues. Current Call for papers:
Next Generation of Synchrophasor-based Power System Monitoring, Operation and Control - https://digital-library.theiet.org/files/IET_GTD_CFP_NGSPSMOC.pdf