不同材料和腔体设计对陶瓷局部覆盖层抗断裂性的影响。

IF 3.2 3区 医学 Q1 DENTISTRY, ORAL SURGERY & MEDICINE
Mahmoud Attia DDS, MSc, PhD, Nadia Fahmy DDS, MSc, PhD, Atef Shaker DDS, MSc, PhD, Tarek Salah DDS, MSc, PhD
{"title":"不同材料和腔体设计对陶瓷局部覆盖层抗断裂性的影响。","authors":"Mahmoud Attia DDS, MSc, PhD,&nbsp;Nadia Fahmy DDS, MSc, PhD,&nbsp;Atef Shaker DDS, MSc, PhD,&nbsp;Tarek Salah DDS, MSc, PhD","doi":"10.1111/jerd.13286","DOIUrl":null,"url":null,"abstract":"<div>\n \n \n <section>\n \n <h3> Background</h3>\n \n <p>Two intra-coronal preparation designs with varying extensions of cuspal coverage can perform differently regarding their fracture resistance against introral forces.</p>\n </section>\n \n <section>\n \n <h3> Methods</h3>\n \n <p>Two materials (IPS e-max CAD [EX], VITA ENAMIC [EN]), and two different preparation designs (EX-D1), (EX-D2), (EN-D1), and (EN-D2) were investigated to compare their fracture resistance. A total of 40 (<i>n</i> = 40) caries free human mandibular molars were used. All the prepared samples were scanned using CEREC Omnicam scanner and the preparations were checked by the software for any sharpness and undercuts before restoration designing and fabrication. All restorations were milled using Cerec MCXL 4.4 milling machine. Duo-Link resin cement was used for cementation. After thermocycling and chewing simulation, all samples were loaded in the Universal testing machine in order to evaluate fracture resistance of all samples.</p>\n </section>\n \n <section>\n \n <h3> Results</h3>\n \n <p>Fracture resistance testing revealed that e-max CAD (2134 N) showed statistically significantly higher mean fracture resistance values than Vita Enamic (1728 N). On the other hand, there was no statistically significant difference between mean fracture resistances between the two tested designs.</p>\n </section>\n \n <section>\n \n <h3> Conclusions</h3>\n \n <p>Within the confines of this investigation, it can be said that although preparation design had no appreciable impact on fracture resistance, the CAD/CAM ceramic material utilized did.</p>\n </section>\n \n <section>\n \n <h3> Clinical Significance</h3>\n \n <p>When restoring compound cavitties indirectly; a conservative defect oriented approach should be used. Glass Ceramic are prefered as restorative material.</p>\n </section>\n </div>","PeriodicalId":15988,"journal":{"name":"Journal of Esthetic and Restorative Dentistry","volume":null,"pages":null},"PeriodicalIF":3.2000,"publicationDate":"2024-07-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"The effect of different materials and cavity designs on fracture resistance of ceramic partial coverage\",\"authors\":\"Mahmoud Attia DDS, MSc, PhD,&nbsp;Nadia Fahmy DDS, MSc, PhD,&nbsp;Atef Shaker DDS, MSc, PhD,&nbsp;Tarek Salah DDS, MSc, PhD\",\"doi\":\"10.1111/jerd.13286\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div>\\n \\n \\n <section>\\n \\n <h3> Background</h3>\\n \\n <p>Two intra-coronal preparation designs with varying extensions of cuspal coverage can perform differently regarding their fracture resistance against introral forces.</p>\\n </section>\\n \\n <section>\\n \\n <h3> Methods</h3>\\n \\n <p>Two materials (IPS e-max CAD [EX], VITA ENAMIC [EN]), and two different preparation designs (EX-D1), (EX-D2), (EN-D1), and (EN-D2) were investigated to compare their fracture resistance. A total of 40 (<i>n</i> = 40) caries free human mandibular molars were used. All the prepared samples were scanned using CEREC Omnicam scanner and the preparations were checked by the software for any sharpness and undercuts before restoration designing and fabrication. All restorations were milled using Cerec MCXL 4.4 milling machine. Duo-Link resin cement was used for cementation. After thermocycling and chewing simulation, all samples were loaded in the Universal testing machine in order to evaluate fracture resistance of all samples.</p>\\n </section>\\n \\n <section>\\n \\n <h3> Results</h3>\\n \\n <p>Fracture resistance testing revealed that e-max CAD (2134 N) showed statistically significantly higher mean fracture resistance values than Vita Enamic (1728 N). On the other hand, there was no statistically significant difference between mean fracture resistances between the two tested designs.</p>\\n </section>\\n \\n <section>\\n \\n <h3> Conclusions</h3>\\n \\n <p>Within the confines of this investigation, it can be said that although preparation design had no appreciable impact on fracture resistance, the CAD/CAM ceramic material utilized did.</p>\\n </section>\\n \\n <section>\\n \\n <h3> Clinical Significance</h3>\\n \\n <p>When restoring compound cavitties indirectly; a conservative defect oriented approach should be used. Glass Ceramic are prefered as restorative material.</p>\\n </section>\\n </div>\",\"PeriodicalId\":15988,\"journal\":{\"name\":\"Journal of Esthetic and Restorative Dentistry\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":3.2000,\"publicationDate\":\"2024-07-30\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Esthetic and Restorative Dentistry\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://onlinelibrary.wiley.com/doi/10.1111/jerd.13286\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"DENTISTRY, ORAL SURGERY & MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Esthetic and Restorative Dentistry","FirstCategoryId":"3","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1111/jerd.13286","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

摘要

背景:两种具有不同牙尖覆盖范围的冠内预备设计在抵抗龈内力时的抗折断性能不同:研究了两种材料(IPS e-max CAD [EX]、VITA ENAMIC [EN])和两种不同的预备设计(EX-D1)、(EX-D2)、(EN-D1)和(EN-D2),以比较它们的抗折性。共使用了 40 颗(n = 40)无龋人类下颌磨牙。在设计和制作修复体之前,使用 CEREC Omnicam 扫描仪对所有制备好的样品进行扫描,并通过软件检查制备的样品是否锋利和有无缺损。所有修复体均使用 Cerec MCXL 4.4 铣床铣制。使用 Duo-Link 树脂粘结剂进行粘结。经过热循环和咀嚼模拟后,将所有样品装入万能试验机,以评估所有样品的抗折性:抗折性能测试表明,e-max CAD(2134 牛顿)的平均抗折性能值明显高于 Vita Enamic(1728 牛顿)。另一方面,两种测试设计的平均抗断裂强度在统计学上没有明显差异:结论:在本次调查范围内,可以说虽然制备设计对抗折性没有明显影响,但所使用的 CAD/CAM 陶瓷材料却对抗折性有明显影响:临床意义:在间接修复复合龋洞时,应采用保守的缺损导向方法。玻璃陶瓷是首选的修复材料。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
The effect of different materials and cavity designs on fracture resistance of ceramic partial coverage

Background

Two intra-coronal preparation designs with varying extensions of cuspal coverage can perform differently regarding their fracture resistance against introral forces.

Methods

Two materials (IPS e-max CAD [EX], VITA ENAMIC [EN]), and two different preparation designs (EX-D1), (EX-D2), (EN-D1), and (EN-D2) were investigated to compare their fracture resistance. A total of 40 (n = 40) caries free human mandibular molars were used. All the prepared samples were scanned using CEREC Omnicam scanner and the preparations were checked by the software for any sharpness and undercuts before restoration designing and fabrication. All restorations were milled using Cerec MCXL 4.4 milling machine. Duo-Link resin cement was used for cementation. After thermocycling and chewing simulation, all samples were loaded in the Universal testing machine in order to evaluate fracture resistance of all samples.

Results

Fracture resistance testing revealed that e-max CAD (2134 N) showed statistically significantly higher mean fracture resistance values than Vita Enamic (1728 N). On the other hand, there was no statistically significant difference between mean fracture resistances between the two tested designs.

Conclusions

Within the confines of this investigation, it can be said that although preparation design had no appreciable impact on fracture resistance, the CAD/CAM ceramic material utilized did.

Clinical Significance

When restoring compound cavitties indirectly; a conservative defect oriented approach should be used. Glass Ceramic are prefered as restorative material.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of Esthetic and Restorative Dentistry
Journal of Esthetic and Restorative Dentistry 医学-牙科与口腔外科
CiteScore
6.30
自引率
6.20%
发文量
124
审稿时长
>12 weeks
期刊介绍: The Journal of Esthetic and Restorative Dentistry (JERD) is the longest standing peer-reviewed journal devoted solely to advancing the knowledge and practice of esthetic dentistry. Its goal is to provide the very latest evidence-based information in the realm of contemporary interdisciplinary esthetic dentistry through high quality clinical papers, sound research reports and educational features. The range of topics covered in the journal includes: - Interdisciplinary esthetic concepts - Implants - Conservative adhesive restorations - Tooth Whitening - Prosthodontic materials and techniques - Dental materials - Orthodontic, periodontal and endodontic esthetics - Esthetics related research - Innovations in esthetics
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信