{"title":"设计和评估用于下颌骨重建的多材料聚合物植入物的机械强度。","authors":"Kalaithendral K, S Karuppudaiyan, Sandipan Roy","doi":"10.1177/03913988241261817","DOIUrl":null,"url":null,"abstract":"<p><p>Reconstruction of mandible implants to address segmental abnormalities is still a challenging task, both in vitro and in vivo. The mechanical strength of the materials used is a critical factor that determines how well bone is regenerated. The reconstruction technique of mandibular abnormalities widely uses polymeric implants. It is critical to evaluate the mechanical resilience under different load cases, including axial, combined, and flexural loading conditions. This study developed implants for mandibular defects using a combination of four materials: polylactic acid (PLA), polyethylene terephthalate glycol (PETG), thermoplastic polyurethane (TPU), and polycaprolactone (PCL), with the aim of mimicking the inherent characteristics of cortical and cancellous bone structures and evaluating their mechanical properties to support bone Osseo integration. The eleven of these combinations of structures result below the micro strain threshold level of <3000 µε, and the five combinations of the structures result in micro strain above the threshold value. The intact bone study results show that the stress under axial, combined, and flexural loading conditions is 27.6, 38.9, and 64.9 MPa, respectively. This study's stress results are lower than those from the intact bone study. The study found that the combinations of PLA and TPU material were most preferred for the cortical and cancellous bone regions of polymeric implants. These materials are also compatible with 3D printing. The results of this study can be used to find multi-material combinations that are strong and flexible.</p>","PeriodicalId":13932,"journal":{"name":"International Journal of Artificial Organs","volume":" ","pages":"698-706"},"PeriodicalIF":1.4000,"publicationDate":"2024-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Design and evaluation of mechanical strength of multi-material polymeric implants for mandibular reconstruction.\",\"authors\":\"Kalaithendral K, S Karuppudaiyan, Sandipan Roy\",\"doi\":\"10.1177/03913988241261817\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Reconstruction of mandible implants to address segmental abnormalities is still a challenging task, both in vitro and in vivo. The mechanical strength of the materials used is a critical factor that determines how well bone is regenerated. The reconstruction technique of mandibular abnormalities widely uses polymeric implants. It is critical to evaluate the mechanical resilience under different load cases, including axial, combined, and flexural loading conditions. This study developed implants for mandibular defects using a combination of four materials: polylactic acid (PLA), polyethylene terephthalate glycol (PETG), thermoplastic polyurethane (TPU), and polycaprolactone (PCL), with the aim of mimicking the inherent characteristics of cortical and cancellous bone structures and evaluating their mechanical properties to support bone Osseo integration. The eleven of these combinations of structures result below the micro strain threshold level of <3000 µε, and the five combinations of the structures result in micro strain above the threshold value. The intact bone study results show that the stress under axial, combined, and flexural loading conditions is 27.6, 38.9, and 64.9 MPa, respectively. This study's stress results are lower than those from the intact bone study. The study found that the combinations of PLA and TPU material were most preferred for the cortical and cancellous bone regions of polymeric implants. These materials are also compatible with 3D printing. The results of this study can be used to find multi-material combinations that are strong and flexible.</p>\",\"PeriodicalId\":13932,\"journal\":{\"name\":\"International Journal of Artificial Organs\",\"volume\":\" \",\"pages\":\"698-706\"},\"PeriodicalIF\":1.4000,\"publicationDate\":\"2024-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Journal of Artificial Organs\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.1177/03913988241261817\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/7/27 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q4\",\"JCRName\":\"ENGINEERING, BIOMEDICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Artificial Organs","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1177/03913988241261817","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/7/27 0:00:00","PubModel":"Epub","JCR":"Q4","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
Design and evaluation of mechanical strength of multi-material polymeric implants for mandibular reconstruction.
Reconstruction of mandible implants to address segmental abnormalities is still a challenging task, both in vitro and in vivo. The mechanical strength of the materials used is a critical factor that determines how well bone is regenerated. The reconstruction technique of mandibular abnormalities widely uses polymeric implants. It is critical to evaluate the mechanical resilience under different load cases, including axial, combined, and flexural loading conditions. This study developed implants for mandibular defects using a combination of four materials: polylactic acid (PLA), polyethylene terephthalate glycol (PETG), thermoplastic polyurethane (TPU), and polycaprolactone (PCL), with the aim of mimicking the inherent characteristics of cortical and cancellous bone structures and evaluating their mechanical properties to support bone Osseo integration. The eleven of these combinations of structures result below the micro strain threshold level of <3000 µε, and the five combinations of the structures result in micro strain above the threshold value. The intact bone study results show that the stress under axial, combined, and flexural loading conditions is 27.6, 38.9, and 64.9 MPa, respectively. This study's stress results are lower than those from the intact bone study. The study found that the combinations of PLA and TPU material were most preferred for the cortical and cancellous bone regions of polymeric implants. These materials are also compatible with 3D printing. The results of this study can be used to find multi-material combinations that are strong and flexible.
期刊介绍:
The International Journal of Artificial Organs (IJAO) publishes peer-reviewed research and clinical, experimental and theoretical, contributions to the field of artificial, bioartificial and tissue-engineered organs. The mission of the IJAO is to foster the development and optimization of artificial, bioartificial and tissue-engineered organs, for implantation or use in procedures, to treat functional deficits of all human tissues and organs.