聚多巴胺封装技术提高了微生物电化学生物毒性传感器的稳定性和检测范围

Biosensors Pub Date : 2024-07-26 DOI:10.3390/bios14080365
Zengfu Guan, Jiaguo Yan, Haiyuan Yan, Bin Li, Lei Guo, Qiang Sun, Tie Geng, Xiaoxuan Guo, Lidong Liu, Wenqing Yan, Xin Wang
{"title":"聚多巴胺封装技术提高了微生物电化学生物毒性传感器的稳定性和检测范围","authors":"Zengfu Guan, Jiaguo Yan, Haiyuan Yan, Bin Li, Lei Guo, Qiang Sun, Tie Geng, Xiaoxuan Guo, Lidong Liu, Wenqing Yan, Xin Wang","doi":"10.3390/bios14080365","DOIUrl":null,"url":null,"abstract":"With the rapid development of modern industry, it is urgently needed to measure the biotoxicity of complex chemicals. Microbial electrochemical biotoxicity sensors are an attractive technology; however, their application is usually limited by their stability and reusability after measurements. Here, we improve their performance by encapsulating the electroactive biofilm with polydopamine (PDA), and we evaluate the improvement by different concentrations of heavy metal ions (Cu2+, Ag+, and Fe3+) in terms of inhibition ratio (IR) and durability. Results indicate that the PDA-encapsulated sensor exhibits a more significant detection concentration than the control group, with a 3-fold increase for Cu2+ and a 1.5-fold increase for Ag+. Moreover, it achieves 15 more continuous toxicity tests than the control group, maintaining high electrochemical activity even after continuous toxicity impacts. Images from a confocal laser scanning microscope reveal that the PDA encapsulation protects the activity of the electroactive biofilm. The study, thus, demonstrates that PDA encapsulation is efficacious in improving the performance of microbial electrochemical biotoxicity sensors, which can extend its application to more complex media.","PeriodicalId":100185,"journal":{"name":"Biosensors","volume":"67 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-07-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Enhanced Stability and Detection Range of Microbial Electrochemical Biotoxicity Sensor by Polydopamine Encapsulation\",\"authors\":\"Zengfu Guan, Jiaguo Yan, Haiyuan Yan, Bin Li, Lei Guo, Qiang Sun, Tie Geng, Xiaoxuan Guo, Lidong Liu, Wenqing Yan, Xin Wang\",\"doi\":\"10.3390/bios14080365\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"With the rapid development of modern industry, it is urgently needed to measure the biotoxicity of complex chemicals. Microbial electrochemical biotoxicity sensors are an attractive technology; however, their application is usually limited by their stability and reusability after measurements. Here, we improve their performance by encapsulating the electroactive biofilm with polydopamine (PDA), and we evaluate the improvement by different concentrations of heavy metal ions (Cu2+, Ag+, and Fe3+) in terms of inhibition ratio (IR) and durability. Results indicate that the PDA-encapsulated sensor exhibits a more significant detection concentration than the control group, with a 3-fold increase for Cu2+ and a 1.5-fold increase for Ag+. Moreover, it achieves 15 more continuous toxicity tests than the control group, maintaining high electrochemical activity even after continuous toxicity impacts. Images from a confocal laser scanning microscope reveal that the PDA encapsulation protects the activity of the electroactive biofilm. The study, thus, demonstrates that PDA encapsulation is efficacious in improving the performance of microbial electrochemical biotoxicity sensors, which can extend its application to more complex media.\",\"PeriodicalId\":100185,\"journal\":{\"name\":\"Biosensors\",\"volume\":\"67 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-07-26\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Biosensors\",\"FirstCategoryId\":\"0\",\"ListUrlMain\":\"https://doi.org/10.3390/bios14080365\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biosensors","FirstCategoryId":"0","ListUrlMain":"https://doi.org/10.3390/bios14080365","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

随着现代工业的快速发展,迫切需要测量复杂化学品的生物毒性。微生物电化学生物毒性传感器是一种极具吸引力的技术,但其应用通常受限于其稳定性和测量后的重复使用性。在这里,我们通过用聚多巴胺(PDA)包裹电活性生物膜来改善其性能,并评估了不同浓度的重金属离子(Cu2+、Ag+ 和 Fe3+)对抑制比(IR)和耐用性的改善作用。结果表明,与对照组相比,PDA 封装传感器的检测浓度更高,Cu2+ 的检测浓度提高了 3 倍,Ag+ 的检测浓度提高了 1.5 倍。此外,它比对照组多进行了 15 次连续毒性测试,即使在连续毒性影响后仍能保持较高的电化学活性。共焦激光扫描显微镜的图像显示,PDA 封装保护了电活性生物膜的活性。因此,该研究表明,PDA 封装可有效改善微生物电化学生物毒性传感器的性能,从而将其应用扩展到更复杂的介质中。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Enhanced Stability and Detection Range of Microbial Electrochemical Biotoxicity Sensor by Polydopamine Encapsulation
With the rapid development of modern industry, it is urgently needed to measure the biotoxicity of complex chemicals. Microbial electrochemical biotoxicity sensors are an attractive technology; however, their application is usually limited by their stability and reusability after measurements. Here, we improve their performance by encapsulating the electroactive biofilm with polydopamine (PDA), and we evaluate the improvement by different concentrations of heavy metal ions (Cu2+, Ag+, and Fe3+) in terms of inhibition ratio (IR) and durability. Results indicate that the PDA-encapsulated sensor exhibits a more significant detection concentration than the control group, with a 3-fold increase for Cu2+ and a 1.5-fold increase for Ag+. Moreover, it achieves 15 more continuous toxicity tests than the control group, maintaining high electrochemical activity even after continuous toxicity impacts. Images from a confocal laser scanning microscope reveal that the PDA encapsulation protects the activity of the electroactive biofilm. The study, thus, demonstrates that PDA encapsulation is efficacious in improving the performance of microbial electrochemical biotoxicity sensors, which can extend its application to more complex media.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信