{"title":"基于太赫兹时频技术的油纸绝缘中的湿气扩散行为","authors":"Yuxin He;Lijun Yang;Xiong Liu;Li Cheng;Meicun Kang;Yong Li","doi":"10.1109/TDEI.2024.3432489","DOIUrl":null,"url":null,"abstract":"Moisture content significantly impacts the electrical strength of oil-paper insulation. Acquiring moisture content accurately and promptly at different points in oil-paper insulation is crucial to assess the risks associated with oil-filled equipment. Moisture primarily resides in the insulating paper within oil-paper insulation, and the change in moisture content in pressboard is a dynamic process, especially after localized dampening. Besides the exchanges between oil and paper, the predominant movement of moisture occurs within different regions of the insulating paper. Previous studies have primarily focused on moisture exchange at the interface between insulating paper and insulating oil. Due to the lack of nondestructive testing methods, exploration of the migration and diffusion of moisture within the internal structure of insulating pressboard is limited. This aspect is pivotal for accurately assessing moisture distribution within the insulation, thereby directly influencing the evaluation of insulation risks. In this study, the rapid and nondestructive sensing capabilities of terahertz (THz) spectroscopy are used to quantify moisture content in solid insulation. The integral value of the absorption coefficient spectrum within the frequency range of 0.3–1 THz serves as a characteristic parameter for quantifying moisture content in insulating paper. A 2-D moisture-diffusion model for localized dampening in pressboard is established based on the Fick model. Using this approach, the diffusion behavior of localized dampening in new and aged oil-impregnated pressboard is demonstrated, and the diffusion coefficient within the pressboard is calculated. A relationship between this coefficient and moisture concentration is determined. Finally, the obtained diffusion coefficient is used to numerically deduce 3-D localized moisture-diffusion behavior within the pressboard.","PeriodicalId":13247,"journal":{"name":"IEEE Transactions on Dielectrics and Electrical Insulation","volume":"31 5","pages":"2621-2631"},"PeriodicalIF":2.9000,"publicationDate":"2024-07-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Moisture-Diffusion Behavior in Oil–Paper Insulation Based on Terahertz Time–Frequency Technology\",\"authors\":\"Yuxin He;Lijun Yang;Xiong Liu;Li Cheng;Meicun Kang;Yong Li\",\"doi\":\"10.1109/TDEI.2024.3432489\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Moisture content significantly impacts the electrical strength of oil-paper insulation. Acquiring moisture content accurately and promptly at different points in oil-paper insulation is crucial to assess the risks associated with oil-filled equipment. Moisture primarily resides in the insulating paper within oil-paper insulation, and the change in moisture content in pressboard is a dynamic process, especially after localized dampening. Besides the exchanges between oil and paper, the predominant movement of moisture occurs within different regions of the insulating paper. Previous studies have primarily focused on moisture exchange at the interface between insulating paper and insulating oil. Due to the lack of nondestructive testing methods, exploration of the migration and diffusion of moisture within the internal structure of insulating pressboard is limited. This aspect is pivotal for accurately assessing moisture distribution within the insulation, thereby directly influencing the evaluation of insulation risks. In this study, the rapid and nondestructive sensing capabilities of terahertz (THz) spectroscopy are used to quantify moisture content in solid insulation. The integral value of the absorption coefficient spectrum within the frequency range of 0.3–1 THz serves as a characteristic parameter for quantifying moisture content in insulating paper. A 2-D moisture-diffusion model for localized dampening in pressboard is established based on the Fick model. Using this approach, the diffusion behavior of localized dampening in new and aged oil-impregnated pressboard is demonstrated, and the diffusion coefficient within the pressboard is calculated. A relationship between this coefficient and moisture concentration is determined. Finally, the obtained diffusion coefficient is used to numerically deduce 3-D localized moisture-diffusion behavior within the pressboard.\",\"PeriodicalId\":13247,\"journal\":{\"name\":\"IEEE Transactions on Dielectrics and Electrical Insulation\",\"volume\":\"31 5\",\"pages\":\"2621-2631\"},\"PeriodicalIF\":2.9000,\"publicationDate\":\"2024-07-24\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"IEEE Transactions on Dielectrics and Electrical Insulation\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://ieeexplore.ieee.org/document/10608177/\",\"RegionNum\":3,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"ENGINEERING, ELECTRICAL & ELECTRONIC\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE Transactions on Dielectrics and Electrical Insulation","FirstCategoryId":"5","ListUrlMain":"https://ieeexplore.ieee.org/document/10608177/","RegionNum":3,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
引用次数: 0

摘要

水分含量对油纸绝缘的电气强度有很大影响。准确、及时地获取油纸绝缘不同部位的含水量对于评估充油设备的相关风险至关重要。水分主要存在于油纸绝缘中的绝缘纸中,而压纸板中的含水量变化是一个动态过程,尤其是在局部受潮后。除了油和纸之间的交换外,湿气的主要移动发生在绝缘纸的不同区域。以往的研究主要集中在绝缘纸和绝缘油界面的水分交换。由于缺乏无损检测方法,对绝缘压纸板内部结构中水分迁移和扩散的研究十分有限。这对于准确评估隔热材料内部的水分分布至关重要,从而直接影响到隔热材料风险的评估。本研究利用太赫兹(THz)光谱的快速和无损传感功能来量化固体绝缘材料中的水分含量。吸收系数光谱在 0.3-1 太赫兹频率范围内的积分值可作为量化绝缘纸中水分含量的特征参数。根据菲克模型,建立了用于压纸板局部阻尼的二维湿气扩散模型。利用这种方法,证明了新的和老化的油浸压纸板中局部阻尼的扩散行为,并计算出了压纸板内的扩散系数。并确定了该系数与水分浓度之间的关系。最后,利用所获得的扩散系数,以数值推导出压纸板内部的三维局部湿气扩散行为。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Moisture-Diffusion Behavior in Oil–Paper Insulation Based on Terahertz Time–Frequency Technology
Moisture content significantly impacts the electrical strength of oil-paper insulation. Acquiring moisture content accurately and promptly at different points in oil-paper insulation is crucial to assess the risks associated with oil-filled equipment. Moisture primarily resides in the insulating paper within oil-paper insulation, and the change in moisture content in pressboard is a dynamic process, especially after localized dampening. Besides the exchanges between oil and paper, the predominant movement of moisture occurs within different regions of the insulating paper. Previous studies have primarily focused on moisture exchange at the interface between insulating paper and insulating oil. Due to the lack of nondestructive testing methods, exploration of the migration and diffusion of moisture within the internal structure of insulating pressboard is limited. This aspect is pivotal for accurately assessing moisture distribution within the insulation, thereby directly influencing the evaluation of insulation risks. In this study, the rapid and nondestructive sensing capabilities of terahertz (THz) spectroscopy are used to quantify moisture content in solid insulation. The integral value of the absorption coefficient spectrum within the frequency range of 0.3–1 THz serves as a characteristic parameter for quantifying moisture content in insulating paper. A 2-D moisture-diffusion model for localized dampening in pressboard is established based on the Fick model. Using this approach, the diffusion behavior of localized dampening in new and aged oil-impregnated pressboard is demonstrated, and the diffusion coefficient within the pressboard is calculated. A relationship between this coefficient and moisture concentration is determined. Finally, the obtained diffusion coefficient is used to numerically deduce 3-D localized moisture-diffusion behavior within the pressboard.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
IEEE Transactions on Dielectrics and Electrical Insulation
IEEE Transactions on Dielectrics and Electrical Insulation 工程技术-工程:电子与电气
CiteScore
6.00
自引率
22.60%
发文量
309
审稿时长
5.2 months
期刊介绍: Topics that are concerned with dielectric phenomena and measurements, with development and characterization of gaseous, vacuum, liquid and solid electrical insulating materials and systems; and with utilization of these materials in circuits and systems under condition of use.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信