Vito Sansone, Giuseppe Auteri, Francesco Tovoli, Camilla Mazzoni, Simona Paglia, Christian Di Pietro, Nicola Vianelli, Michele Cavo, Francesca Palandri, Fabio Piscaglia
{"title":"肝脏和脾脏剪切波弹性成像在骨髓增生性疾病和骨髓纤维化的诊断和严重程度分期中的应用。","authors":"Vito Sansone, Giuseppe Auteri, Francesco Tovoli, Camilla Mazzoni, Simona Paglia, Christian Di Pietro, Nicola Vianelli, Michele Cavo, Francesca Palandri, Fabio Piscaglia","doi":"10.1007/s40477-024-00932-6","DOIUrl":null,"url":null,"abstract":"<p><strong>Aims: </strong>Spleen and liver stiffness, investigated by VCTE (Vibration-Controlled Transient Elastography), have been associated with marrow fibrosis in patients with myeloproliferative neoplasms (MPNs). Tissue stiffness can be assessed by shear wave point (pSWE) and bidimensional elastography (2DSWE). Spleen stiffness (SS) values were higher in Myelofibrosis (MF) and Polycythemia Vera (PV) compared to Essential Thrombocythemia (ET). We aimed to identify SWE differences between MPN patients and healthy volunteers; to evaluate specific SWE features in patients with MF, PV and ET; to establish a correlation with bone marrow fibrosis in patients with myeloproliferative disease.</p><p><strong>Methods: </strong>Patients with myeloproliferative disease and healthy volunteers performed evaluation of spleen and liver stiffness (LS) by pSWE and 2DSWE.</p><p><strong>Results: </strong>A total of 218 subjects were included: 143 with myeloproliferative disease (64 MF, 29.4%, 33 PV, 15.1% and 46 ET, 21.1%), and 75 (34.4%) healthy volunteers. Compared to volunteers, MF patients had greater spleen (pSWE 40.9 vs. 26.3 kPa, p < 0.001; 2DSWE 34.9 vs. 20.1 kPa, p < 0.001), and liver stiffness (pSWE 7.72 vs. 5.52 kPa, p < 0.001; 2DSWE 6.96 vs. 5.01 kPa, p < 0.001). In low (0-1) (n = 81, 60.4%) versus high-grade bone marrow fibrosis (2-3) (n = 42, 39.6%), is evident a higher median stiffness in patients with higher grades of fibrosis both for liver (pSWE 5.2 vs. 6.65 kPa; 2DSWE 5.1 vs. 6.05 kPa) and spleen (pSWE 27.2 vs. 37.9 kPa, 2DSWE 21.7 vs 30.75 kPa-p < 0.001 in both).</p><p><strong>Conclusion: </strong>SWE evaluation distinguishes MF patients from HV and ET/PV and may help in MPN diagnosis. LS and SS values are associated with bone marrow fibrosis grade.</p>","PeriodicalId":51528,"journal":{"name":"Journal of Ultrasound","volume":null,"pages":null},"PeriodicalIF":1.3000,"publicationDate":"2024-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11333402/pdf/","citationCount":"0","resultStr":"{\"title\":\"Liver and spleen shear-wave elastography in the diagnosis and severity staging of myeloproliferative diseases and myelofibrosis.\",\"authors\":\"Vito Sansone, Giuseppe Auteri, Francesco Tovoli, Camilla Mazzoni, Simona Paglia, Christian Di Pietro, Nicola Vianelli, Michele Cavo, Francesca Palandri, Fabio Piscaglia\",\"doi\":\"10.1007/s40477-024-00932-6\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Aims: </strong>Spleen and liver stiffness, investigated by VCTE (Vibration-Controlled Transient Elastography), have been associated with marrow fibrosis in patients with myeloproliferative neoplasms (MPNs). Tissue stiffness can be assessed by shear wave point (pSWE) and bidimensional elastography (2DSWE). Spleen stiffness (SS) values were higher in Myelofibrosis (MF) and Polycythemia Vera (PV) compared to Essential Thrombocythemia (ET). We aimed to identify SWE differences between MPN patients and healthy volunteers; to evaluate specific SWE features in patients with MF, PV and ET; to establish a correlation with bone marrow fibrosis in patients with myeloproliferative disease.</p><p><strong>Methods: </strong>Patients with myeloproliferative disease and healthy volunteers performed evaluation of spleen and liver stiffness (LS) by pSWE and 2DSWE.</p><p><strong>Results: </strong>A total of 218 subjects were included: 143 with myeloproliferative disease (64 MF, 29.4%, 33 PV, 15.1% and 46 ET, 21.1%), and 75 (34.4%) healthy volunteers. Compared to volunteers, MF patients had greater spleen (pSWE 40.9 vs. 26.3 kPa, p < 0.001; 2DSWE 34.9 vs. 20.1 kPa, p < 0.001), and liver stiffness (pSWE 7.72 vs. 5.52 kPa, p < 0.001; 2DSWE 6.96 vs. 5.01 kPa, p < 0.001). In low (0-1) (n = 81, 60.4%) versus high-grade bone marrow fibrosis (2-3) (n = 42, 39.6%), is evident a higher median stiffness in patients with higher grades of fibrosis both for liver (pSWE 5.2 vs. 6.65 kPa; 2DSWE 5.1 vs. 6.05 kPa) and spleen (pSWE 27.2 vs. 37.9 kPa, 2DSWE 21.7 vs 30.75 kPa-p < 0.001 in both).</p><p><strong>Conclusion: </strong>SWE evaluation distinguishes MF patients from HV and ET/PV and may help in MPN diagnosis. LS and SS values are associated with bone marrow fibrosis grade.</p>\",\"PeriodicalId\":51528,\"journal\":{\"name\":\"Journal of Ultrasound\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.3000,\"publicationDate\":\"2024-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11333402/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Ultrasound\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1007/s40477-024-00932-6\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/7/26 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q3\",\"JCRName\":\"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Ultrasound","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1007/s40477-024-00932-6","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/7/26 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
Liver and spleen shear-wave elastography in the diagnosis and severity staging of myeloproliferative diseases and myelofibrosis.
Aims: Spleen and liver stiffness, investigated by VCTE (Vibration-Controlled Transient Elastography), have been associated with marrow fibrosis in patients with myeloproliferative neoplasms (MPNs). Tissue stiffness can be assessed by shear wave point (pSWE) and bidimensional elastography (2DSWE). Spleen stiffness (SS) values were higher in Myelofibrosis (MF) and Polycythemia Vera (PV) compared to Essential Thrombocythemia (ET). We aimed to identify SWE differences between MPN patients and healthy volunteers; to evaluate specific SWE features in patients with MF, PV and ET; to establish a correlation with bone marrow fibrosis in patients with myeloproliferative disease.
Methods: Patients with myeloproliferative disease and healthy volunteers performed evaluation of spleen and liver stiffness (LS) by pSWE and 2DSWE.
Results: A total of 218 subjects were included: 143 with myeloproliferative disease (64 MF, 29.4%, 33 PV, 15.1% and 46 ET, 21.1%), and 75 (34.4%) healthy volunteers. Compared to volunteers, MF patients had greater spleen (pSWE 40.9 vs. 26.3 kPa, p < 0.001; 2DSWE 34.9 vs. 20.1 kPa, p < 0.001), and liver stiffness (pSWE 7.72 vs. 5.52 kPa, p < 0.001; 2DSWE 6.96 vs. 5.01 kPa, p < 0.001). In low (0-1) (n = 81, 60.4%) versus high-grade bone marrow fibrosis (2-3) (n = 42, 39.6%), is evident a higher median stiffness in patients with higher grades of fibrosis both for liver (pSWE 5.2 vs. 6.65 kPa; 2DSWE 5.1 vs. 6.05 kPa) and spleen (pSWE 27.2 vs. 37.9 kPa, 2DSWE 21.7 vs 30.75 kPa-p < 0.001 in both).
Conclusion: SWE evaluation distinguishes MF patients from HV and ET/PV and may help in MPN diagnosis. LS and SS values are associated with bone marrow fibrosis grade.
期刊介绍:
The Journal of Ultrasound is the official journal of the Italian Society for Ultrasound in Medicine and Biology (SIUMB). The journal publishes original contributions (research and review articles, case reports, technical reports and letters to the editor) on significant advances in clinical diagnostic, interventional and therapeutic applications, clinical techniques, the physics, engineering and technology of ultrasound in medicine and biology, and in cross-sectional diagnostic imaging. The official language of Journal of Ultrasound is English.