使用高度细分的 HPGe 探测器进行肺部计数。

IF 1.6 3区 工程技术 Q3 CHEMISTRY, INORGANIC & NUCLEAR
{"title":"使用高度细分的 HPGe 探测器进行肺部计数。","authors":"","doi":"10.1016/j.apradiso.2024.111452","DOIUrl":null,"url":null,"abstract":"<div><p>A highly segmented High-Purity Germanium (HPGe) detector was used to measure <sup>241</sup>Am activity located inside the lungs of an anthropomorphic phantom with various active and passive shield configurations. It was found that the background suppression shield does not play a significant role in reducing the Minimum Detectable Activity (MDA) after veto, based on the segmentation in the depth direction of the HPGe, when measuring low-energy gamma rays. A reduction of up to 57% in the MDA was achieved. The MDA could be further improved by a thinner lateral segmentation and an optimized anti-Compton shield coupled with an active or passive backplate. The new detector application would be particularly useful in mobile whole-body counting units, where the natural background radiation poses a challenge when measuring low-energy gamma rays.</p></div>","PeriodicalId":8096,"journal":{"name":"Applied Radiation and Isotopes","volume":null,"pages":null},"PeriodicalIF":1.6000,"publicationDate":"2024-07-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.sciencedirect.com/science/article/pii/S096980432400280X/pdfft?md5=6ec0f99177d14d917188d762239fbb0a&pid=1-s2.0-S096980432400280X-main.pdf","citationCount":"0","resultStr":"{\"title\":\"Lung counting with a highly segmented HPGe detector\",\"authors\":\"\",\"doi\":\"10.1016/j.apradiso.2024.111452\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>A highly segmented High-Purity Germanium (HPGe) detector was used to measure <sup>241</sup>Am activity located inside the lungs of an anthropomorphic phantom with various active and passive shield configurations. It was found that the background suppression shield does not play a significant role in reducing the Minimum Detectable Activity (MDA) after veto, based on the segmentation in the depth direction of the HPGe, when measuring low-energy gamma rays. A reduction of up to 57% in the MDA was achieved. The MDA could be further improved by a thinner lateral segmentation and an optimized anti-Compton shield coupled with an active or passive backplate. The new detector application would be particularly useful in mobile whole-body counting units, where the natural background radiation poses a challenge when measuring low-energy gamma rays.</p></div>\",\"PeriodicalId\":8096,\"journal\":{\"name\":\"Applied Radiation and Isotopes\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.6000,\"publicationDate\":\"2024-07-20\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.sciencedirect.com/science/article/pii/S096980432400280X/pdfft?md5=6ec0f99177d14d917188d762239fbb0a&pid=1-s2.0-S096980432400280X-main.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Applied Radiation and Isotopes\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S096980432400280X\",\"RegionNum\":3,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"CHEMISTRY, INORGANIC & NUCLEAR\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Applied Radiation and Isotopes","FirstCategoryId":"5","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S096980432400280X","RegionNum":3,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"CHEMISTRY, INORGANIC & NUCLEAR","Score":null,"Total":0}
引用次数: 0

摘要

利用高度分段的高纯锗(HPGe)探测器测量了拟人模型肺内的 241Am 放射性活度,并采用了不同的主动和被动屏蔽配置。研究发现,在测量低能量伽马射线时,根据 HPGe 深度方向的分割,背景抑制屏蔽在否决后降低最小可探测放射性(MDA)方面作用不大。MDA 降低了 57%。通过更薄的横向分割和优化的反康普顿屏蔽以及主动或被动背板,可以进一步提高 MDA。新探测器在移动式全身计数装置中的应用将特别有用,因为在测量低能量伽马射线时,天然本底辐射会带来挑战。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Lung counting with a highly segmented HPGe detector

A highly segmented High-Purity Germanium (HPGe) detector was used to measure 241Am activity located inside the lungs of an anthropomorphic phantom with various active and passive shield configurations. It was found that the background suppression shield does not play a significant role in reducing the Minimum Detectable Activity (MDA) after veto, based on the segmentation in the depth direction of the HPGe, when measuring low-energy gamma rays. A reduction of up to 57% in the MDA was achieved. The MDA could be further improved by a thinner lateral segmentation and an optimized anti-Compton shield coupled with an active or passive backplate. The new detector application would be particularly useful in mobile whole-body counting units, where the natural background radiation poses a challenge when measuring low-energy gamma rays.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Applied Radiation and Isotopes
Applied Radiation and Isotopes 工程技术-核科学技术
CiteScore
3.00
自引率
12.50%
发文量
406
审稿时长
13.5 months
期刊介绍: Applied Radiation and Isotopes provides a high quality medium for the publication of substantial, original and scientific and technological papers on the development and peaceful application of nuclear, radiation and radionuclide techniques in chemistry, physics, biochemistry, biology, medicine, security, engineering and in the earth, planetary and environmental sciences, all including dosimetry. Nuclear techniques are defined in the broadest sense and both experimental and theoretical papers are welcome. They include the development and use of α- and β-particles, X-rays and γ-rays, neutrons and other nuclear particles and radiations from all sources, including radionuclides, synchrotron sources, cyclotrons and reactors and from the natural environment. The journal aims to publish papers with significance to an international audience, containing substantial novelty and scientific impact. The Editors reserve the rights to reject, with or without external review, papers that do not meet these criteria. Papers dealing with radiation processing, i.e., where radiation is used to bring about a biological, chemical or physical change in a material, should be directed to our sister journal Radiation Physics and Chemistry.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信