{"title":"人工耳蜗中的听觉脑干电反应测听:新的记录范例。","authors":"Takwa Gabr, Hossam Debis, Ahmed Hafez","doi":"10.3390/audiolres14040049","DOIUrl":null,"url":null,"abstract":"<p><p>(1) Background: Cochlear implants (CIs) are widely applied to recover audition for patients with severe degrees of or total hearing loss. Electrical stimulation using the electrically evoked ABR (E-ABR) can be recorded in CI recipients through the device. This work was designed to study E-ABR recorded individually from different channels located at the apical, middle, and basal cochlear regions in comparison to their simultaneous separated or adjacent combined recordings. (2) Methods: This study included 17 children fitted with unilateral cochlear implants. All children were subjected to impedance measurement, electrical compound action potentials (ECAP), and E-ABR recording of three channels located at the apical, middle, and basal cochlear regions. This was followed by simultaneous E-ABR recording of the three \"separated\" channels in comparison to E-ABR recording from three adjacent channels located at the middle cochlear region. (3) Results: Similar E-ABR latencies and amplitudes were found using either individual or simultaneously separated or adjacent combined recording. However, the mean amplitude measures of E-ABR for combined adjacent channels showed a positive correlation with the applied current level. (4) Conclusions: Combined E-ABR recording from adjacent channels is a faster and more reliable technique that can be used effectively without compromising the results of the recorded E-ABR.</p>","PeriodicalId":44133,"journal":{"name":"Audiology Research","volume":null,"pages":null},"PeriodicalIF":2.1000,"publicationDate":"2024-06-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11270165/pdf/","citationCount":"0","resultStr":"{\"title\":\"Electric Auditory Brainstem Response Audiometry in Cochlear Implants: New Recording Paradigm.\",\"authors\":\"Takwa Gabr, Hossam Debis, Ahmed Hafez\",\"doi\":\"10.3390/audiolres14040049\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>(1) Background: Cochlear implants (CIs) are widely applied to recover audition for patients with severe degrees of or total hearing loss. Electrical stimulation using the electrically evoked ABR (E-ABR) can be recorded in CI recipients through the device. This work was designed to study E-ABR recorded individually from different channels located at the apical, middle, and basal cochlear regions in comparison to their simultaneous separated or adjacent combined recordings. (2) Methods: This study included 17 children fitted with unilateral cochlear implants. All children were subjected to impedance measurement, electrical compound action potentials (ECAP), and E-ABR recording of three channels located at the apical, middle, and basal cochlear regions. This was followed by simultaneous E-ABR recording of the three \\\"separated\\\" channels in comparison to E-ABR recording from three adjacent channels located at the middle cochlear region. (3) Results: Similar E-ABR latencies and amplitudes were found using either individual or simultaneously separated or adjacent combined recording. However, the mean amplitude measures of E-ABR for combined adjacent channels showed a positive correlation with the applied current level. (4) Conclusions: Combined E-ABR recording from adjacent channels is a faster and more reliable technique that can be used effectively without compromising the results of the recorded E-ABR.</p>\",\"PeriodicalId\":44133,\"journal\":{\"name\":\"Audiology Research\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":2.1000,\"publicationDate\":\"2024-06-26\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11270165/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Audiology Research\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.3390/audiolres14040049\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"AUDIOLOGY & SPEECH-LANGUAGE PATHOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Audiology Research","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3390/audiolres14040049","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"AUDIOLOGY & SPEECH-LANGUAGE PATHOLOGY","Score":null,"Total":0}
Electric Auditory Brainstem Response Audiometry in Cochlear Implants: New Recording Paradigm.
(1) Background: Cochlear implants (CIs) are widely applied to recover audition for patients with severe degrees of or total hearing loss. Electrical stimulation using the electrically evoked ABR (E-ABR) can be recorded in CI recipients through the device. This work was designed to study E-ABR recorded individually from different channels located at the apical, middle, and basal cochlear regions in comparison to their simultaneous separated or adjacent combined recordings. (2) Methods: This study included 17 children fitted with unilateral cochlear implants. All children were subjected to impedance measurement, electrical compound action potentials (ECAP), and E-ABR recording of three channels located at the apical, middle, and basal cochlear regions. This was followed by simultaneous E-ABR recording of the three "separated" channels in comparison to E-ABR recording from three adjacent channels located at the middle cochlear region. (3) Results: Similar E-ABR latencies and amplitudes were found using either individual or simultaneously separated or adjacent combined recording. However, the mean amplitude measures of E-ABR for combined adjacent channels showed a positive correlation with the applied current level. (4) Conclusions: Combined E-ABR recording from adjacent channels is a faster and more reliable technique that can be used effectively without compromising the results of the recorded E-ABR.
期刊介绍:
The mission of Audiology Research is to publish contemporary, ethical, clinically relevant scientific researches related to the basic science and clinical aspects of the auditory and vestibular system and diseases of the ear that can be used by clinicians, scientists and specialists to improve understanding and treatment of patients with audiological and neurotological disorders.