{"title":"常染色体显性多囊肾病的肾脏总体积:两种核磁共振成像方法在观察者内部和观察者之间的一致性。","authors":"Elif Gündoğdu, Çağatay Cihan, Celal Yazici","doi":"10.55730/1300-0144.5820","DOIUrl":null,"url":null,"abstract":"<p><strong>Background/aim: </strong>Total kidney volume (TKV) is a parameter used in both treatment decision and follow-up in autosomal dominant polycystic kidney disease (ADPKD) patients. The objective of this study was to evaluate intra- and interobserver agreement of the ellipsoid formula (EF) and manual boundary tracing method (MBTM) used in TKV measurement of ADPKD patients across different levels of experience radiologists. Additionally, the study aimed to evaluate the correlation between the EF and MBTM, which is considered the gold standard for TKV.</p><p><strong>Materials and methods: </strong>A retrospective evaluation was conducted on magnetic resonance imaging (MRI) data from 55 ADPKD patients who underwent abdominal MRI between January 2017 and November 2021 to evaluate TKV. TKV measurements were performed by three independent observers (observer 1, an abdominal imaging radiologist with 5 years of experience; observer 2, a fourth-year radiology resident; observer 3, a second-year radiology resident).To assess intraobserver variability, all observers repeated the measurements at two-week intervals. The ICC was used to assess both intraobserver and interobserver variability. A comparison of the two methods was performed by linear regression for all three observers.</p><p><strong>Results: </strong>The ICC (95% CI) indicated excellent agreement between the observers for both methods (among all observers, p < 0.001). Furthermore, excellent intraobserver agreement was found between all observer measurements either EF or MBTM based on ICC (95% CI) (p < 0.001). The results of the linear regression analysis demonstrated high correlations between the two methods in all three observers (r = 0.992, p < 0.001 for the first observer; r = 0.975, p < 0.001 for the second observer; r = 0.989, p < 0.001 for the third observer).</p><p><strong>Conclusion: </strong>Both the EF and MBTM methods used for the measurement of TKV provided excellent intra- and interobserver reproducibility. The EF is as accurate and precise as the MBTM. It may therefore be preferred in radiology departments with heavy workload, as it is a reliable method for rapid and easy assessment, independent of experience.</p>","PeriodicalId":1,"journal":{"name":"Accounts of Chemical Research","volume":null,"pages":null},"PeriodicalIF":16.4000,"publicationDate":"2024-01-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11265870/pdf/","citationCount":"0","resultStr":"{\"title\":\"Total kidney volume in autosomal dominant polycystic kidney disease: intraobserver and interobserver agreement of two methods with MRI.\",\"authors\":\"Elif Gündoğdu, Çağatay Cihan, Celal Yazici\",\"doi\":\"10.55730/1300-0144.5820\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background/aim: </strong>Total kidney volume (TKV) is a parameter used in both treatment decision and follow-up in autosomal dominant polycystic kidney disease (ADPKD) patients. The objective of this study was to evaluate intra- and interobserver agreement of the ellipsoid formula (EF) and manual boundary tracing method (MBTM) used in TKV measurement of ADPKD patients across different levels of experience radiologists. Additionally, the study aimed to evaluate the correlation between the EF and MBTM, which is considered the gold standard for TKV.</p><p><strong>Materials and methods: </strong>A retrospective evaluation was conducted on magnetic resonance imaging (MRI) data from 55 ADPKD patients who underwent abdominal MRI between January 2017 and November 2021 to evaluate TKV. TKV measurements were performed by three independent observers (observer 1, an abdominal imaging radiologist with 5 years of experience; observer 2, a fourth-year radiology resident; observer 3, a second-year radiology resident).To assess intraobserver variability, all observers repeated the measurements at two-week intervals. The ICC was used to assess both intraobserver and interobserver variability. A comparison of the two methods was performed by linear regression for all three observers.</p><p><strong>Results: </strong>The ICC (95% CI) indicated excellent agreement between the observers for both methods (among all observers, p < 0.001). Furthermore, excellent intraobserver agreement was found between all observer measurements either EF or MBTM based on ICC (95% CI) (p < 0.001). The results of the linear regression analysis demonstrated high correlations between the two methods in all three observers (r = 0.992, p < 0.001 for the first observer; r = 0.975, p < 0.001 for the second observer; r = 0.989, p < 0.001 for the third observer).</p><p><strong>Conclusion: </strong>Both the EF and MBTM methods used for the measurement of TKV provided excellent intra- and interobserver reproducibility. The EF is as accurate and precise as the MBTM. It may therefore be preferred in radiology departments with heavy workload, as it is a reliable method for rapid and easy assessment, independent of experience.</p>\",\"PeriodicalId\":1,\"journal\":{\"name\":\"Accounts of Chemical Research\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":16.4000,\"publicationDate\":\"2024-01-05\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11265870/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Accounts of Chemical Research\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.55730/1300-0144.5820\",\"RegionNum\":1,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/1/1 0:00:00\",\"PubModel\":\"eCollection\",\"JCR\":\"Q1\",\"JCRName\":\"CHEMISTRY, MULTIDISCIPLINARY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Accounts of Chemical Research","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.55730/1300-0144.5820","RegionNum":1,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/1/1 0:00:00","PubModel":"eCollection","JCR":"Q1","JCRName":"CHEMISTRY, MULTIDISCIPLINARY","Score":null,"Total":0}
Total kidney volume in autosomal dominant polycystic kidney disease: intraobserver and interobserver agreement of two methods with MRI.
Background/aim: Total kidney volume (TKV) is a parameter used in both treatment decision and follow-up in autosomal dominant polycystic kidney disease (ADPKD) patients. The objective of this study was to evaluate intra- and interobserver agreement of the ellipsoid formula (EF) and manual boundary tracing method (MBTM) used in TKV measurement of ADPKD patients across different levels of experience radiologists. Additionally, the study aimed to evaluate the correlation between the EF and MBTM, which is considered the gold standard for TKV.
Materials and methods: A retrospective evaluation was conducted on magnetic resonance imaging (MRI) data from 55 ADPKD patients who underwent abdominal MRI between January 2017 and November 2021 to evaluate TKV. TKV measurements were performed by three independent observers (observer 1, an abdominal imaging radiologist with 5 years of experience; observer 2, a fourth-year radiology resident; observer 3, a second-year radiology resident).To assess intraobserver variability, all observers repeated the measurements at two-week intervals. The ICC was used to assess both intraobserver and interobserver variability. A comparison of the two methods was performed by linear regression for all three observers.
Results: The ICC (95% CI) indicated excellent agreement between the observers for both methods (among all observers, p < 0.001). Furthermore, excellent intraobserver agreement was found between all observer measurements either EF or MBTM based on ICC (95% CI) (p < 0.001). The results of the linear regression analysis demonstrated high correlations between the two methods in all three observers (r = 0.992, p < 0.001 for the first observer; r = 0.975, p < 0.001 for the second observer; r = 0.989, p < 0.001 for the third observer).
Conclusion: Both the EF and MBTM methods used for the measurement of TKV provided excellent intra- and interobserver reproducibility. The EF is as accurate and precise as the MBTM. It may therefore be preferred in radiology departments with heavy workload, as it is a reliable method for rapid and easy assessment, independent of experience.
期刊介绍:
Accounts of Chemical Research presents short, concise and critical articles offering easy-to-read overviews of basic research and applications in all areas of chemistry and biochemistry. These short reviews focus on research from the author’s own laboratory and are designed to teach the reader about a research project. In addition, Accounts of Chemical Research publishes commentaries that give an informed opinion on a current research problem. Special Issues online are devoted to a single topic of unusual activity and significance.
Accounts of Chemical Research replaces the traditional article abstract with an article "Conspectus." These entries synopsize the research affording the reader a closer look at the content and significance of an article. Through this provision of a more detailed description of the article contents, the Conspectus enhances the article's discoverability by search engines and the exposure for the research.