{"title":"学龄儿童眼底视盘大小、颜色和杯盘比的纵向变化。","authors":"Seiji Sameshima, Takehiro Yamashita, Hiroto Terasaki, Ryo Asaoka, Naoya Yoshihara, Naoko Kakiuchi, Taiji Sakamoto","doi":"10.1186/s40942-024-00570-4","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>To investigate the relationship between changes in the optic disc size and color, cup-to-disc (C/D) ratio, and axial elongation in schoolchildren.</p><p><strong>Methods: </strong>A prospective cohort study was performed in 75 right eyes of elementary school students for six years (from 8.5 to 14.5 years old). In the first and last year, all participants underwent optical axial length measurement and color fundus photography. The optic disc color was calculated by dividing the intensity of red by the sum of the intensity of red, green, and blue. The optic disc area was calculated by modifying the number of pixels according to Bennett's formula. The C/D ratio was calculated by dividing the vertical cup diameter by vertical optic disc diameter. Wilcoxon signed rank test was used to compare these optic disc parameters and axial length in the first and last year.</p><p><strong>Results: </strong>Mean axial length in the last year (24.82 mm) was significantly longer than that in the first year (23.34 mm). Likewise, the mean optic disc size was significantly smaller in the last year (41,946 pixels) than that in the first year (46,144 pixels). The mean optic disc color in the last year (0.49) was significantly more reddish than that in the first year (0.46), while the mean C/D ratio in last year (0.50) was significantly smaller than that in first year (0.52).</p><p><strong>Conclusions: </strong>During the period from 8.5 years to 14.5 years of age, both the optic disc size and C/D ratio became smaller, while the color became more red.</p>","PeriodicalId":14289,"journal":{"name":"International Journal of Retina and Vitreous","volume":null,"pages":null},"PeriodicalIF":1.9000,"publicationDate":"2024-07-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11270882/pdf/","citationCount":"0","resultStr":"{\"title\":\"Longitudinal changes of funduscopic optic disc size, color and cup-to-disc ratio in school children.\",\"authors\":\"Seiji Sameshima, Takehiro Yamashita, Hiroto Terasaki, Ryo Asaoka, Naoya Yoshihara, Naoko Kakiuchi, Taiji Sakamoto\",\"doi\":\"10.1186/s40942-024-00570-4\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>To investigate the relationship between changes in the optic disc size and color, cup-to-disc (C/D) ratio, and axial elongation in schoolchildren.</p><p><strong>Methods: </strong>A prospective cohort study was performed in 75 right eyes of elementary school students for six years (from 8.5 to 14.5 years old). In the first and last year, all participants underwent optical axial length measurement and color fundus photography. The optic disc color was calculated by dividing the intensity of red by the sum of the intensity of red, green, and blue. The optic disc area was calculated by modifying the number of pixels according to Bennett's formula. The C/D ratio was calculated by dividing the vertical cup diameter by vertical optic disc diameter. Wilcoxon signed rank test was used to compare these optic disc parameters and axial length in the first and last year.</p><p><strong>Results: </strong>Mean axial length in the last year (24.82 mm) was significantly longer than that in the first year (23.34 mm). Likewise, the mean optic disc size was significantly smaller in the last year (41,946 pixels) than that in the first year (46,144 pixels). The mean optic disc color in the last year (0.49) was significantly more reddish than that in the first year (0.46), while the mean C/D ratio in last year (0.50) was significantly smaller than that in first year (0.52).</p><p><strong>Conclusions: </strong>During the period from 8.5 years to 14.5 years of age, both the optic disc size and C/D ratio became smaller, while the color became more red.</p>\",\"PeriodicalId\":14289,\"journal\":{\"name\":\"International Journal of Retina and Vitreous\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.9000,\"publicationDate\":\"2024-07-25\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11270882/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Journal of Retina and Vitreous\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1186/s40942-024-00570-4\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"OPHTHALMOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Retina and Vitreous","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1186/s40942-024-00570-4","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
Longitudinal changes of funduscopic optic disc size, color and cup-to-disc ratio in school children.
Background: To investigate the relationship between changes in the optic disc size and color, cup-to-disc (C/D) ratio, and axial elongation in schoolchildren.
Methods: A prospective cohort study was performed in 75 right eyes of elementary school students for six years (from 8.5 to 14.5 years old). In the first and last year, all participants underwent optical axial length measurement and color fundus photography. The optic disc color was calculated by dividing the intensity of red by the sum of the intensity of red, green, and blue. The optic disc area was calculated by modifying the number of pixels according to Bennett's formula. The C/D ratio was calculated by dividing the vertical cup diameter by vertical optic disc diameter. Wilcoxon signed rank test was used to compare these optic disc parameters and axial length in the first and last year.
Results: Mean axial length in the last year (24.82 mm) was significantly longer than that in the first year (23.34 mm). Likewise, the mean optic disc size was significantly smaller in the last year (41,946 pixels) than that in the first year (46,144 pixels). The mean optic disc color in the last year (0.49) was significantly more reddish than that in the first year (0.46), while the mean C/D ratio in last year (0.50) was significantly smaller than that in first year (0.52).
Conclusions: During the period from 8.5 years to 14.5 years of age, both the optic disc size and C/D ratio became smaller, while the color became more red.
期刊介绍:
International Journal of Retina and Vitreous focuses on the ophthalmic subspecialty of vitreoretinal disorders. The journal presents original articles on new approaches to diagnosis, outcomes of clinical trials, innovations in pharmacological therapy and surgical techniques, as well as basic science advances that impact clinical practice. Topical areas include, but are not limited to: -Imaging of the retina, choroid and vitreous -Innovations in optical coherence tomography (OCT) -Small-gauge vitrectomy, retinal detachment, chromovitrectomy -Electroretinography (ERG), microperimetry, other functional tests -Intraocular tumors -Retinal pharmacotherapy & drug delivery -Diabetic retinopathy & other vascular diseases -Age-related macular degeneration (AMD) & other macular entities