用户背景知识和息肉特征对计算机辅助结肠镜检查的影响

IF 3.4 3区 医学 Q2 GASTROENTEROLOGY & HEPATOLOGY
Gut and Liver Pub Date : 2024-09-15 Epub Date: 2024-07-26 DOI:10.5009/gnl240068
Jooyoung Lee, Woo Sang Cho, Byeong Soo Kim, Dan Yoon, Jung Kim, Ji Hyun Song, Sun Young Yang, Seon Hee Lim, Goh Eun Chung, Ji Min Choi, Yoo Min Han, Hyoun-Joong Kong, Jung Chan Lee, Sungwan Kim, Jung Ho Bae
{"title":"用户背景知识和息肉特征对计算机辅助结肠镜检查的影响","authors":"Jooyoung Lee, Woo Sang Cho, Byeong Soo Kim, Dan Yoon, Jung Kim, Ji Hyun Song, Sun Young Yang, Seon Hee Lim, Goh Eun Chung, Ji Min Choi, Yoo Min Han, Hyoun-Joong Kong, Jung Chan Lee, Sungwan Kim, Jung Ho Bae","doi":"10.5009/gnl240068","DOIUrl":null,"url":null,"abstract":"<p><strong>Background/aims: </strong>We investigated how interactions between humans and computer-aided detection (CADe) systems are influenced by the user's experience and polyp characteristics.</p><p><strong>Methods: </strong>We developed a CADe system using YOLOv4, trained on 16,996 polyp images from 1,914 patients and 1,800 synthesized sessile serrated lesion (SSL) images. The performance of polyp detection with CADe assistance was evaluated using a computerized test module. Eighteen participants were grouped by colonoscopy experience (nurses, fellows, and experts). The value added by CADe based on the histopathology and detection difficulty of polyps were analyzed.</p><p><strong>Results: </strong>The area under the curve for CADe was 0.87 (95% confidence interval [CI], 0.83 to 0.91). CADe assistance increased overall polyp detection accuracy from 69.7% to 77.7% (odds ratio [OR], 1.88; 95% CI, 1.69 to 2.09). However, accuracy decreased when CADe inaccurately detected a polyp (OR, 0.72; 95% CI, 0.58 to 0.87). The impact of CADe assistance was most and least prominent in the nurses (OR, 1.97; 95% CI, 1.71 to 2.27) and the experts (OR, 1.42; 95% CI, 1.15 to 1.74), respectively. Participants demonstrated better sensitivity with CADe assistance, achieving 81.7% for adenomas and 92.4% for easy-to-detect polyps, surpassing the standalone CADe performance of 79.7% and 89.8%, respectively. For SSLs and difficult-to-detect polyps, participants' sensitivities with CADe assistance (66.5% and 71.5%, respectively) were below those of standalone CADe (81.1% and 74.4%). Compared to the other two groups (56.1% and 61.7%), the expert group showed sensitivity closest to that of standalone CADe in detecting SSLs (79.7% vs 81.1%, respectively).</p><p><strong>Conclusions: </strong>CADe assistance boosts polyp detection significantly, but its effectiveness depends on the user's experience, particularly for challenging lesions.</p>","PeriodicalId":12885,"journal":{"name":"Gut and Liver","volume":" ","pages":"857-866"},"PeriodicalIF":3.4000,"publicationDate":"2024-09-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11391145/pdf/","citationCount":"0","resultStr":"{\"title\":\"Impact of User's Background Knowledge and Polyp Characteristics in Colonoscopy with Computer-Aided Detection.\",\"authors\":\"Jooyoung Lee, Woo Sang Cho, Byeong Soo Kim, Dan Yoon, Jung Kim, Ji Hyun Song, Sun Young Yang, Seon Hee Lim, Goh Eun Chung, Ji Min Choi, Yoo Min Han, Hyoun-Joong Kong, Jung Chan Lee, Sungwan Kim, Jung Ho Bae\",\"doi\":\"10.5009/gnl240068\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background/aims: </strong>We investigated how interactions between humans and computer-aided detection (CADe) systems are influenced by the user's experience and polyp characteristics.</p><p><strong>Methods: </strong>We developed a CADe system using YOLOv4, trained on 16,996 polyp images from 1,914 patients and 1,800 synthesized sessile serrated lesion (SSL) images. The performance of polyp detection with CADe assistance was evaluated using a computerized test module. Eighteen participants were grouped by colonoscopy experience (nurses, fellows, and experts). The value added by CADe based on the histopathology and detection difficulty of polyps were analyzed.</p><p><strong>Results: </strong>The area under the curve for CADe was 0.87 (95% confidence interval [CI], 0.83 to 0.91). CADe assistance increased overall polyp detection accuracy from 69.7% to 77.7% (odds ratio [OR], 1.88; 95% CI, 1.69 to 2.09). However, accuracy decreased when CADe inaccurately detected a polyp (OR, 0.72; 95% CI, 0.58 to 0.87). The impact of CADe assistance was most and least prominent in the nurses (OR, 1.97; 95% CI, 1.71 to 2.27) and the experts (OR, 1.42; 95% CI, 1.15 to 1.74), respectively. Participants demonstrated better sensitivity with CADe assistance, achieving 81.7% for adenomas and 92.4% for easy-to-detect polyps, surpassing the standalone CADe performance of 79.7% and 89.8%, respectively. For SSLs and difficult-to-detect polyps, participants' sensitivities with CADe assistance (66.5% and 71.5%, respectively) were below those of standalone CADe (81.1% and 74.4%). Compared to the other two groups (56.1% and 61.7%), the expert group showed sensitivity closest to that of standalone CADe in detecting SSLs (79.7% vs 81.1%, respectively).</p><p><strong>Conclusions: </strong>CADe assistance boosts polyp detection significantly, but its effectiveness depends on the user's experience, particularly for challenging lesions.</p>\",\"PeriodicalId\":12885,\"journal\":{\"name\":\"Gut and Liver\",\"volume\":\" \",\"pages\":\"857-866\"},\"PeriodicalIF\":3.4000,\"publicationDate\":\"2024-09-15\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11391145/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Gut and Liver\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.5009/gnl240068\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/7/26 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q2\",\"JCRName\":\"GASTROENTEROLOGY & HEPATOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Gut and Liver","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.5009/gnl240068","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/7/26 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"GASTROENTEROLOGY & HEPATOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

背景/目的:我们研究了人与计算机辅助检测(CADe)系统之间的互动如何受到用户经验和息肉特征的影响:我们使用 YOLOv4 开发了计算机辅助检测(CADe)系统,并对来自 1,914 名患者的 16,996 张息肉图像和 1,800 张合成的无柄锯齿状病变(SSL)图像进行了训练。使用计算机化测试模块对 CADe 辅助下的息肉检测性能进行了评估。18 名参与者按结肠镜检查经验分组(护士、研究员和专家)。分析了基于组织病理学和息肉检测难度的 CADe 附加值:CADe 的曲线下面积为 0.87(95% 置信区间 [CI],0.83 至 0.91)。在 CADe 的帮助下,息肉检测的总体准确率从 69.7% 提高到了 77.7%(几率比 [OR],1.88;95% 置信区间 [CI],1.69 至 2.09)。但是,当 CADe 检测出息肉不准确时,准确率会下降(OR,0.72;95% CI,0.58 至 0.87)。CADe 辅助对护士(OR,1.97;95% CI,1.71 至 2.27)和专家(OR,1.42;95% CI,1.15 至 1.74)的影响分别最大和最小。在 CADe 的辅助下,参与者表现出更高的灵敏度,腺瘤灵敏度达到 81.7%,易检测息肉灵敏度达到 92.4%,分别超过了独立 CADe 的 79.7% 和 89.8%。对于 SSL 和难以检测的息肉,参与者在 CADe 辅助下的灵敏度(分别为 66.5% 和 71.5%)低于独立 CADe 的灵敏度(分别为 81.1% 和 74.4%)。与其他两组(56.1% 和 61.7%)相比,专家组在检测 SSL 方面的灵敏度最接近独立 CADe(分别为 79.7% 和 81.1%):结论:CADe 辅助技术能显著提高息肉的检测率,但其效果取决于使用者的经验,尤其是对高难度病变的检测。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Impact of User's Background Knowledge and Polyp Characteristics in Colonoscopy with Computer-Aided Detection.

Background/aims: We investigated how interactions between humans and computer-aided detection (CADe) systems are influenced by the user's experience and polyp characteristics.

Methods: We developed a CADe system using YOLOv4, trained on 16,996 polyp images from 1,914 patients and 1,800 synthesized sessile serrated lesion (SSL) images. The performance of polyp detection with CADe assistance was evaluated using a computerized test module. Eighteen participants were grouped by colonoscopy experience (nurses, fellows, and experts). The value added by CADe based on the histopathology and detection difficulty of polyps were analyzed.

Results: The area under the curve for CADe was 0.87 (95% confidence interval [CI], 0.83 to 0.91). CADe assistance increased overall polyp detection accuracy from 69.7% to 77.7% (odds ratio [OR], 1.88; 95% CI, 1.69 to 2.09). However, accuracy decreased when CADe inaccurately detected a polyp (OR, 0.72; 95% CI, 0.58 to 0.87). The impact of CADe assistance was most and least prominent in the nurses (OR, 1.97; 95% CI, 1.71 to 2.27) and the experts (OR, 1.42; 95% CI, 1.15 to 1.74), respectively. Participants demonstrated better sensitivity with CADe assistance, achieving 81.7% for adenomas and 92.4% for easy-to-detect polyps, surpassing the standalone CADe performance of 79.7% and 89.8%, respectively. For SSLs and difficult-to-detect polyps, participants' sensitivities with CADe assistance (66.5% and 71.5%, respectively) were below those of standalone CADe (81.1% and 74.4%). Compared to the other two groups (56.1% and 61.7%), the expert group showed sensitivity closest to that of standalone CADe in detecting SSLs (79.7% vs 81.1%, respectively).

Conclusions: CADe assistance boosts polyp detection significantly, but its effectiveness depends on the user's experience, particularly for challenging lesions.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Gut and Liver
Gut and Liver 医学-胃肠肝病学
CiteScore
7.50
自引率
8.80%
发文量
119
审稿时长
6-12 weeks
期刊介绍: Gut and Liver is an international journal of gastroenterology, focusing on the gastrointestinal tract, liver, biliary tree, pancreas, motility, and neurogastroenterology. Gut and Liver delivers up-to-date, authoritative papers on both clinical and research-based topics in gastroenterology. The Journal publishes original articles, case reports, brief communications, letters to the editor and invited review articles in the field of gastroenterology. The Journal is operated by internationally renowned editorial boards and designed to provide a global opportunity to promote academic developments in the field of gastroenterology and hepatology. Gut and Liver is jointly owned and operated by 8 affiliated societies in the field of gastroenterology, namely: the Korean Society of Gastroenterology, the Korean Society of Gastrointestinal Endoscopy, the Korean Society of Neurogastroenterology and Motility, the Korean College of Helicobacter and Upper Gastrointestinal Research, the Korean Association for the Study of Intestinal Diseases, the Korean Association for the Study of the Liver, the Korean Pancreatobiliary Association, and the Korean Society of Gastrointestinal Cancer.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信