对 DSAEK 载体进行简单改装,就能在不影响内皮细胞活力的情况下通过注射插入移植物。

IF 1.9 3区 医学 Q2 OPHTHALMOLOGY
Cornea Pub Date : 2025-01-01 Epub Date: 2024-07-26 DOI:10.1097/ICO.0000000000003629
Megan M W Straiko, Emma V Letchworth, Philip K Dye, Joshua D Galloway, Khoa D Tran
{"title":"对 DSAEK 载体进行简单改装,就能在不影响内皮细胞活力的情况下通过注射插入移植物。","authors":"Megan M W Straiko, Emma V Letchworth, Philip K Dye, Joshua D Galloway, Khoa D Tran","doi":"10.1097/ICO.0000000000003629","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>We evaluate the quality and feasibility of preloading Descemet stripping automated endothelial keratoplasty (DSAEK) grafts into a modified EndoGlide Ultrathin system for graft injection.</p><p><strong>Methods: </strong>DSAEK grafts were prepared by experienced processing technicians at 2 separate locations, loaded into a modified EndoGlide Ultrathin, and placed in storage media. Grafts processed at one location were shipped cross-country overnight to the other location and were examined on arrival for positioning within the modified EndoGlide Ultrathin. All grafts were ejected and analyzed for endothelial cell loss (ECL) with calcein acetoxymethyl staining and FIJI segmentation. A subset of grafts was measured by optical coherence tomography for graft thickness 1 hour after cut, 1 hour after loading, and 1 day after loading.</p><p><strong>Results: </strong>No grafts were displaced from the modified carrier over 3 shipping events (n = 9), and all grafts (n = 18) were successfully ejected. Grafts loaded into the modified carrier and ejected exhibited no more cell loss than grafts loaded into the standard carrier and removed by pull-through (14.0% ± 2.8% vs. 12.2% ± 3.4%, respectively, P = 0.24). Carrier modification skills can be successfully transferred as grafts loaded by a processing technician new to carrier modification were within the acceptable limit of 25% ECL for transplant DSAEK grafts. Graft thickness increased significantly ( P < 0.05) between the postcut and 1-hour postload measurement and the postcut and 24-hour postload measurement.</p><p><strong>Conclusions: </strong>The EndoGlide Ultrathin can be modified to enable its use for graft injection while not compromising the ability to use the pull-through method for graft delivery. Preloaded DSAEK grafts swell significantly during the 24-hour storage period, and patterns of ECL may be linked to swelling.</p>","PeriodicalId":10710,"journal":{"name":"Cornea","volume":" ","pages":"98-103"},"PeriodicalIF":1.9000,"publicationDate":"2025-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Simple Modification of a DSAEK Carrier Enables Graft Insertion by Injection Without Compromising Endothelial Cell Viability.\",\"authors\":\"Megan M W Straiko, Emma V Letchworth, Philip K Dye, Joshua D Galloway, Khoa D Tran\",\"doi\":\"10.1097/ICO.0000000000003629\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>We evaluate the quality and feasibility of preloading Descemet stripping automated endothelial keratoplasty (DSAEK) grafts into a modified EndoGlide Ultrathin system for graft injection.</p><p><strong>Methods: </strong>DSAEK grafts were prepared by experienced processing technicians at 2 separate locations, loaded into a modified EndoGlide Ultrathin, and placed in storage media. Grafts processed at one location were shipped cross-country overnight to the other location and were examined on arrival for positioning within the modified EndoGlide Ultrathin. All grafts were ejected and analyzed for endothelial cell loss (ECL) with calcein acetoxymethyl staining and FIJI segmentation. A subset of grafts was measured by optical coherence tomography for graft thickness 1 hour after cut, 1 hour after loading, and 1 day after loading.</p><p><strong>Results: </strong>No grafts were displaced from the modified carrier over 3 shipping events (n = 9), and all grafts (n = 18) were successfully ejected. Grafts loaded into the modified carrier and ejected exhibited no more cell loss than grafts loaded into the standard carrier and removed by pull-through (14.0% ± 2.8% vs. 12.2% ± 3.4%, respectively, P = 0.24). Carrier modification skills can be successfully transferred as grafts loaded by a processing technician new to carrier modification were within the acceptable limit of 25% ECL for transplant DSAEK grafts. Graft thickness increased significantly ( P < 0.05) between the postcut and 1-hour postload measurement and the postcut and 24-hour postload measurement.</p><p><strong>Conclusions: </strong>The EndoGlide Ultrathin can be modified to enable its use for graft injection while not compromising the ability to use the pull-through method for graft delivery. Preloaded DSAEK grafts swell significantly during the 24-hour storage period, and patterns of ECL may be linked to swelling.</p>\",\"PeriodicalId\":10710,\"journal\":{\"name\":\"Cornea\",\"volume\":\" \",\"pages\":\"98-103\"},\"PeriodicalIF\":1.9000,\"publicationDate\":\"2025-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Cornea\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1097/ICO.0000000000003629\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/7/26 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q2\",\"JCRName\":\"OPHTHALMOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Cornea","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1097/ICO.0000000000003629","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/7/26 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

目的:我们评估了将 Descemet 剥脱自动内皮角膜移植术(DSAEK)移植物预先装入改良的 EndoGlide Ultrathin 系统进行移植物注射的质量和可行性:方法:DSAEK 移植物由经验丰富的处理技术人员在两个不同的地点进行准备,装入改良的 EndoGlide Ultrathin 系统,并放入储存介质中。一个地点处理好的移植物连夜跨国运送到另一个地点,到达后检查移植物在改良的 EndoGlide Ultrathin 中的定位情况。所有移植物都被取出,并通过钙黄绿素乙酰氧甲基染色和 FIJI 分段分析内皮细胞丢失 (ECL)。切割后 1 小时、加载后 1 小时和加载后 1 天,通过光学相干断层扫描测量移植物的厚度:结果:在 3 次装运过程中,没有移植物从改良载体中移出(9 例),所有移植物(18 例)均成功弹出。装入改良载体并弹出的移植物与装入标准载体并通过拉通取出的移植物相比,细胞丢失率没有增加(分别为 14.0% ± 2.8% vs. 12.2% ± 3.4%,P = 0.24)。载体改良技能可以成功传授,因为由刚接触载体改良的加工技师装入的移植物的ECL在移植DSAEK移植物25%的可接受范围内。在切割后和1小时后载荷测量之间,以及切割后和24小时后载荷测量之间,移植物厚度明显增加(P < 0.05):结论:可以对 EndoGlide Ultrathin 进行改装,使其既能用于移植物注射,又不影响使用拉通法输送移植物。预载的 DSAEK 移植物在 24 小时储存期间会明显肿胀,ECL 的模式可能与肿胀有关。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Simple Modification of a DSAEK Carrier Enables Graft Insertion by Injection Without Compromising Endothelial Cell Viability.

Purpose: We evaluate the quality and feasibility of preloading Descemet stripping automated endothelial keratoplasty (DSAEK) grafts into a modified EndoGlide Ultrathin system for graft injection.

Methods: DSAEK grafts were prepared by experienced processing technicians at 2 separate locations, loaded into a modified EndoGlide Ultrathin, and placed in storage media. Grafts processed at one location were shipped cross-country overnight to the other location and were examined on arrival for positioning within the modified EndoGlide Ultrathin. All grafts were ejected and analyzed for endothelial cell loss (ECL) with calcein acetoxymethyl staining and FIJI segmentation. A subset of grafts was measured by optical coherence tomography for graft thickness 1 hour after cut, 1 hour after loading, and 1 day after loading.

Results: No grafts were displaced from the modified carrier over 3 shipping events (n = 9), and all grafts (n = 18) were successfully ejected. Grafts loaded into the modified carrier and ejected exhibited no more cell loss than grafts loaded into the standard carrier and removed by pull-through (14.0% ± 2.8% vs. 12.2% ± 3.4%, respectively, P = 0.24). Carrier modification skills can be successfully transferred as grafts loaded by a processing technician new to carrier modification were within the acceptable limit of 25% ECL for transplant DSAEK grafts. Graft thickness increased significantly ( P < 0.05) between the postcut and 1-hour postload measurement and the postcut and 24-hour postload measurement.

Conclusions: The EndoGlide Ultrathin can be modified to enable its use for graft injection while not compromising the ability to use the pull-through method for graft delivery. Preloaded DSAEK grafts swell significantly during the 24-hour storage period, and patterns of ECL may be linked to swelling.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Cornea
Cornea 医学-眼科学
CiteScore
5.20
自引率
10.70%
发文量
354
审稿时长
3-6 weeks
期刊介绍: For corneal specialists and for all general ophthalmologists with an interest in this exciting subspecialty, Cornea brings together the latest clinical and basic research on the cornea and the anterior segment of the eye. Each volume is peer-reviewed by Cornea''s board of world-renowned experts and fully indexed in archival format. Your subscription brings you the latest developments in your field and a growing library of valuable professional references. Sponsored by The Cornea Society which was founded as the Castroviejo Cornea Society in 1975.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信